Screening for coronary artery disease in respiratory patients: comparison of single- and dual-source CT in patients with a heart rate above 70 bpm

被引:0
|
作者
Vittorio Pansini
Martine Remy-Jardin
Nunzia Tacelli
Jean-Baptiste Faivre
Thomas Flohr
Valérie Deken
Alain Duhamel
Jacques Remy
机构
[1] University Center of Lille,Department of Thoracic Imaging, Hospital Calmette
[2] Siemens Medical Solutions,Department of Research and Development
[3] University Center of Lille,Department of Medical Statistics
来源
European Radiology | 2008年 / 18卷
关键词
Coronary arteries; Dual-source CT; CT angiography;
D O I
暂无
中图分类号
学科分类号
摘要
To evaluate the assessibility of coronary arteries in respiratory patients with high heart rates. This study was based on the comparative analysis of two paired populations of 54 patients with a heart rate >70 bpm evaluated with dual-source (group 1) and single-source (group 2) CT. The mean heart rate was 89.1 bpm in group 1 and 86.7 bpm in group 2 (P = 0.26). The mean number of assessable segments per patient was significantly higher in group 1 compared to group 2 (P ≤ 0.0001). The proportions of patients in whom proximal and mid-coronary segments were assessable (i.e., the anatomical level enabling screening for asymptomatic coronary artery disease) were 35.3% for heart rates <110 bpm, 35.6% for heart rates <100 bpm, 40% for heart rates <90 bpm, and 60% for heart rates <80 bpm in group 1 and 11.3, 12.2, 8.8, and 10% for the corresponding thresholds in group 2 (P < 0.05). In both groups of patients, coronary artery imaging was obtained from standard CT angiograms of the chest. The improvement in coronary imaging with dual-source CT suggests that high heart rates should no longer be considered as contraindications for ECG-gated CT angiograms of the chest whenever clinically relevant.
引用
收藏
页码:2108 / 2119
页数:11
相关论文
共 50 条
  • [21] Diagnostic Accuracy of Dual-Source CT Coronary Angiography with Prospective ECG Triggering on Different Heart Rate Patients
    Sun, M. L.
    CARDIOLOGY, 2010, 117 : 114 - 115
  • [22] Dual-source CT coronary angiography without heart rate or rhythm control in comparison with conventional coronary angiography
    Fang, Xiang Ming
    Chen, Hong Wei
    Hu, Xiao Yun
    Bao, Jian
    Chen, Yin
    Yang, Zhen Yu
    Buckley, Orla
    Wu, Xiao Qing
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (03): : 323 - 331
  • [23] Congenital coronary artery fistulas: dual-source CT findings from consecutive 6624 patients with suspected or confirmed coronary artery disease
    Yun Hong
    Zeng Meng-su
    Yang Shan
    Jin Hang
    Yang Xue
    CHINESE MEDICAL JOURNAL, 2011, 124 (24) : 4172 - 4177
  • [24] Dual-source CT coronary angiography without heart rate or rhythm control in comparison with conventional coronary angiography
    Xiang Ming Fang
    Hong Wei Chen
    Xiao Yun Hu
    Jian Bao
    Yin Chen
    Zhen Yu Yang
    Orla Buckley
    Xiao Qing Wu
    The International Journal of Cardiovascular Imaging, 2010, 26 : 323 - 331
  • [25] Dual-source CT coronary angiography: Image quality, mean heart rate, and heart rate variability
    Matt, David
    Scheffel, Hans
    Leschka, Sebastian
    Flohr, Thomas G.
    Marincek, Borut
    Kaufmann, Philipp A.
    Alkadhi, Hatem
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (03) : 567 - 573
  • [26] Diagnostic accuracy of dual-source CT coronary angiography with prospective ECG-triggering on different heart rate patients
    Ming-li Sun
    Bin Lu
    Run-ze Wu
    Laura Johnson
    Lei Han
    Gang Liu
    Fang-Fang Yu
    Zhi-hui Hou
    Yang Gao
    Hong-yu Wang
    Shiliang Jiang
    Yue-jin Yang
    Shu-bin Qiao
    European Radiology, 2011, 21 : 1635 - 1642
  • [27] Diagnostic accuracy of dual-source CT coronary angiography with prospective ECG-triggering on different heart rate patients
    Sun, Ming-li
    Lu, Bin
    Wu, Run-ze
    Johnson, Laura
    Han, Lei
    Liu, Gang
    Yu, Fang-Fang
    Hou, Zhi-hui
    Gao, Yang
    Wang, Hong-yu
    Jiang, Shiliang
    Yang, Yue-jin
    Qiao, Shu-bin
    EUROPEAN RADIOLOGY, 2011, 21 (08) : 1635 - 1642
  • [28] Accuracy of dual-source computed tomography to identify significant coronary artery disease in patients with atrial fibrillation: comparison with coronary angiography
    Marwan, Mohamed
    Pflederer, Tobias
    Schepis, Tiziano
    Lang, Alexandra
    Muschiol, Gerd
    Ropers, Dieter
    Daniel, Werner G.
    Achenbach, Stephan
    EUROPEAN HEART JOURNAL, 2010, 31 (18) : 2230 - 2237
  • [29] Analysis of Image Quality of Coronary Artery and Radiation Dose by Dual-Source CT in Children with Congenital Heart Disease
    Gao, Y.
    Lv, B.
    Hou, Z. H.
    Johnson, L.
    Wu, R. Z.
    Chen, X. B.
    Sun, M. L.
    Yu, F. F.
    Han, L.
    Bai, H.
    Jiang, S. L.
    Dai, R. P.
    CARDIOLOGY, 2010, 117 : 111 - 111
  • [30] Low-dose adaptive sequential scan for dual-source CT coronary angiography in patients with high heart rate: Comparison with retrospective ECG gating
    Xu, Lei
    Yang, Lin
    Zhang, Zhaoqi
    Li, Yu
    Fan, Zhanming
    Ma, Xiaohai
    Lv, Biao
    Yu, Wei
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 76 (02) : 183 - 187