Diaphragm Electrical Activity During Expiration in Mechanically Ventilated Infants

被引:0
|
作者
Guillaume Emeriaud
Jennifer Beck
Marisa Tucci
Jacques Lacroix
Christer Sinderby
机构
[1] Hôpital Sainte-Justine,Department of Pediatrics
[2] Centre Hospitalier Universitaire,Department of Pediatrics
[3] Sunnybrook and Women's College Health Sciences Centre,Department of Newborn and Developmental Pediatrics
[4] Hôpital Sainte-Justine Research Center,Department of Critical Care Medicine
[5] Université de Montréal,undefined
[6] St-Michael's Hospital,undefined
[7] University of Toronto,undefined
来源
Pediatric Research | 2006年 / 59卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The presence of diaphragm electrical activity (EAdi) during expiration is believed to be involved in the maintenance of end-expiratory lung volume (EELV) and has never been studied in intubated and mechanically ventilated infants. The aim of this study was to quantify the amplitude of diaphragm electrical activity present during expiration in mechanically ventilated infants and to measure the impact of removing positive end-expiratory pressure (PEEP) on this activity. We studied the EAdi in 16 ready-to-be weaned intubated infants who were breathing on their prescribed ventilator and PEEP settings. In all 16 patients, 5 min of data were collected on the prescribed ventilator settings. In a subset of eight patients, the PEEP was briefly reduced to zero PEEP (ZEEP). EAdi was recorded with miniaturized sensors placed on a conventional nasogastric feeding tube. Airway pressure (Paw) was also measured. For each spontaneous breath, we identified the neural inspiration and neural expiration. Neural expiration was divided into quartiles (Q1, Q2, Q3, and Q4), and the amplitude of EAdi calculated for each Q1–Q4 represented 95 ± 29%, 31 ± 15%, 15 ± 8%, and 12 ± 7%, respectively, of the inspiratory EAdi amplitude. EAdi for Q3–Q4 significantly increased during ZEEP, and decreased after reapplication of PEEP. These findings confirm that the diaphragm remains partially active during expiration in intubated and mechanically ventilated infants and that removal of PEEP affects this tonic activity. This could have potential implications on the management of PEEP in intubated infants.
引用
收藏
页码:705 / 710
页数:5
相关论文
共 50 条
  • [41] TIME CONSTANT VOLUME RELATIONSHIP OF PASSIVE EXPIRATION IN MECHANICALLY VENTILATED ARDS PATIENTS
    GUTTMANN, J
    EBERHARD, L
    FABRY, B
    BERTSCHMANN, W
    ZERAVIK, J
    ADOLPH, M
    ECKART, J
    WOLFF, G
    EUROPEAN RESPIRATORY JOURNAL, 1995, 8 (01) : 114 - 120
  • [42] Validation of the Better Care® system to detect ineffective efforts during expiration in mechanically ventilated patients: a pilot study
    Lluis Blanch
    Bernat Sales
    Jaume Montanya
    Umberto Lucangelo
    Oscar Garcia-Esquirol
    Ana Villagra
    Encarna Chacon
    Anna Estruga
    Massimo Borelli
    Ma Jose Burgueño
    Joan C. Oliva
    Rafael Fernandez
    Jesus Villar
    Robert Kacmarek
    Gastón Murias
    Intensive Care Medicine, 2012, 38 : 772 - 780
  • [43] Diaphragm echodensity in mechanically ventilated patients: a description of technique and outcomes
    Coiffard, Benjamin
    Riegler, Stephen
    Sklar, Michael C.
    Dres, Martin
    Vorona, Stefannie
    Reid, W. Darlene
    Brochard, Laurent J.
    Ferguson, Niall D.
    Goligher, Ewan C.
    CRITICAL CARE, 2021, 25 (01)
  • [44] Relationship Of Diaphragm Weakness To Death In Mechanically Ventilated MICU Patients
    Supinski, G. S.
    Callahan, L. P.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [45] Severe Diaphragm Fiber Weakness In Mechanically Ventilated Icu Patients
    Hooijman, P. E.
    De Waard, M.
    Bouwman, A.
    Lommen, W.
    Van Hees, H.
    Hartemink, K.
    Stienen, G.
    Paul, M.
    Beishuizen, A.
    Ottenheijm, C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [46] ASSOCIATION OF DIAPHRAGM ATROPHY AND EXCURSION WITH EXTUBATION IN MECHANICALLY VENTILATED CHILDREN
    Sadasivam, Deepthika
    Bansal, Arun
    Jayashree, Muralidharan
    Sodhi, Kushaljit Singh
    Nallasamy, Karthi
    Angurana, Suresh
    CRITICAL CARE MEDICINE, 2024, 52
  • [47] Rapid disuse atrophy of diaphragm fibers in mechanically ventilated humans
    Levine, Sanford
    Nguyen, Taitan
    Taylor, Nyali
    Friscia, Michael E.
    Budak, Murat T.
    Rothenberg, Pamela
    Zhu, Jianliang
    Sachdeva, Rajeev
    Sonnad, Seema
    Kaiser, Larry R.
    Rubinstein, Neal A.
    Powers, Scott K.
    Shrager, Joseph B.
    NEW ENGLAND JOURNAL OF MEDICINE, 2008, 358 (13): : 1327 - 1335
  • [48] Diaphragm echodensity in mechanically ventilated patients: a description of technique and outcomes
    Benjamin Coiffard
    Stephen Riegler
    Michael C. Sklar
    Martin Dres
    Stefannie Vorona
    W. Darlene Reid
    Laurent J. Brochard
    Niall D. Ferguson
    Ewan C. Goligher
    Critical Care, 25
  • [49] Reversible Sepsis Induced Diaphragm Dysfunction in Mechanically Ventilated Patients
    Dres, M.
    Lecronier, M.
    Jung, B.
    Molinari, N.
    Pinot, J.
    Jaber, S.
    Similowski, T.
    Demoule, A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2022, 205
  • [50] Alterations of the Diaphragm in Mechanically Ventilated Patients Died on ICU.
    Agten, A.
    Testelmans, D.
    Maes, K.
    Hermans, G.
    De Leyn, P.
    Decramer, M.
    Gayan-Ramirez, G.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179