Diaphragm Electrical Activity During Expiration in Mechanically Ventilated Infants

被引:0
|
作者
Guillaume Emeriaud
Jennifer Beck
Marisa Tucci
Jacques Lacroix
Christer Sinderby
机构
[1] Hôpital Sainte-Justine,Department of Pediatrics
[2] Centre Hospitalier Universitaire,Department of Pediatrics
[3] Sunnybrook and Women's College Health Sciences Centre,Department of Newborn and Developmental Pediatrics
[4] Hôpital Sainte-Justine Research Center,Department of Critical Care Medicine
[5] Université de Montréal,undefined
[6] St-Michael's Hospital,undefined
[7] University of Toronto,undefined
来源
Pediatric Research | 2006年 / 59卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The presence of diaphragm electrical activity (EAdi) during expiration is believed to be involved in the maintenance of end-expiratory lung volume (EELV) and has never been studied in intubated and mechanically ventilated infants. The aim of this study was to quantify the amplitude of diaphragm electrical activity present during expiration in mechanically ventilated infants and to measure the impact of removing positive end-expiratory pressure (PEEP) on this activity. We studied the EAdi in 16 ready-to-be weaned intubated infants who were breathing on their prescribed ventilator and PEEP settings. In all 16 patients, 5 min of data were collected on the prescribed ventilator settings. In a subset of eight patients, the PEEP was briefly reduced to zero PEEP (ZEEP). EAdi was recorded with miniaturized sensors placed on a conventional nasogastric feeding tube. Airway pressure (Paw) was also measured. For each spontaneous breath, we identified the neural inspiration and neural expiration. Neural expiration was divided into quartiles (Q1, Q2, Q3, and Q4), and the amplitude of EAdi calculated for each Q1–Q4 represented 95 ± 29%, 31 ± 15%, 15 ± 8%, and 12 ± 7%, respectively, of the inspiratory EAdi amplitude. EAdi for Q3–Q4 significantly increased during ZEEP, and decreased after reapplication of PEEP. These findings confirm that the diaphragm remains partially active during expiration in intubated and mechanically ventilated infants and that removal of PEEP affects this tonic activity. This could have potential implications on the management of PEEP in intubated infants.
引用
收藏
页码:705 / 710
页数:5
相关论文
共 50 条
  • [1] Diaphragm electrical activity during expiration in mechanically ventilated infants
    Emeriaud, G
    Beck, J
    Tucci, M
    Lacroix, J
    Sinderby, C
    PEDIATRIC RESEARCH, 2006, 59 (05) : 705 - 710
  • [2] Studying Diaphragm Activity during Expiration in Mechanically Ventilated Patients: Expiratory Asynchrony Is Important
    Akoumianaki, Evangelia
    Bolaki, Maria
    Georgopoulos, Dimitris
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209 (11) : 1410 - 1411
  • [3] Influence of caffeine on the electrical activity of the diaphragm of mechanically ventilated, very premature infants
    Williams, Emma
    Jeyakara, Janathan
    Hunt, Katie
    Dassios, Theodore
    Greenough, Anne
    EUROPEAN RESPIRATORY JOURNAL, 2019, 54
  • [4] Diaphragm Activity during Expiration in Ventilated Critically Ill Patients
    de Vries, Heder J.
    Jonkman, Annemijn H.
    Holleboom, Minke C.
    de Grooth, Harm J.
    Shi, Zhonghua
    Ottenheijm, Coen A.
    de Man, Angelique M.
    Tuinman, Pieter R.
    Heunks, Leo
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209 (07) : 881 - 883
  • [5] Reply to Akoumianaki et al.: Studying Diaphragm Activity during Expiration in Mechanically Ventilated Patients: Expiratory Asynchrony Is Important
    de Vries, Heder Jonathan
    Heunks, Leo
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209 (11) : 1411 - 1412
  • [6] Electrical Activity To Determine The Start Of Diaphragm Activity In Mechanically Ventilated Patients: An Observational Study
    Rauseo, M.
    Soliman, I.
    Chen, L.
    Rittayamai, N.
    Chen, G. -Q.
    Sklar, M.
    Campbell, C.
    Goligher, E. C.
    Friedrich, J. O.
    Sinderby, C. A.
    Heunks, L.
    Brochard, L. J.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [7] Electrical activity of the diaphragm following a loading dose of caffeine citrate in ventilated preterm infants
    Williams, Emma E.
    Hunt, Katie A.
    Jeyakara, Janathan
    Subba-Rao, Raghavendra
    Dassios, Theodore
    Greenough, Anne
    PEDIATRIC RESEARCH, 2020, 87 (04) : 740 - 744
  • [8] Electrical activity of the diaphragm following a loading dose of caffeine citrate in ventilated preterm infants
    Emma E. Williams
    Katie A. Hunt
    Janathan Jeyakara
    Raghavendra Subba-Rao
    Theodore Dassios
    Anne Greenough
    Pediatric Research, 2020, 87 : 740 - 744
  • [9] Diaphragm Dysfunction in Mechanically Ventilated Patients
    Dot, Irene
    Perez-Teran, Purificacion
    Samper, Manuel -Andres
    Masclans, Y. Joan-Ramon
    ARCHIVOS DE BRONCONEUMOLOGIA, 2017, 53 (03): : 150 - 156
  • [10] Reliability of ultrasonic diaphragm thickness measurement in mechanically ventilated infants and children: A pilot study
    Terhart, M. N.
    Hanekom, S.
    Lupton-Smith, A.
    Morrow, B.
    SOUTHERN AFRICAN JOURNAL OF CRITICAL CARE, 2018, 34 (01) : 22 - 27