Stimulation of Titanium Implant Osseointegration Through High-Frequency Vibration Loading is Enhanced when Applied at High Acceleration

被引:0
|
作者
Toru Ogawa
Katleen Vandamme
Xiaolei Zhang
Ignace Naert
Tine Possemiers
Amol Chaudhari
Keiichi Sasaki
Joke Duyck
机构
[1] KU Leuven & University Hospitals Leuven,BIOMAT KU Leuven, Department of Oral Health Sciences & Dental Clinic
[2] Tohoku University Graduate School of Dentistry,Division of Advanced Prosthetic Dentistry
[3] Sun Yat-sen University,Guanghua School of Stomatology, Hospital of Stomatology
来源
Calcified Tissue International | 2014年 / 95卷
关键词
Titanium implant osseointegration; Whole body vibration; Frequency; Acceleration; Rat tibia;
D O I
暂无
中图分类号
学科分类号
摘要
Low-magnitude high-frequency loading, applied by means of whole body vibration (WBV), affects the bone. Deconstructing a WBV loading stimulus into its constituent elements and investigating the effects of frequency and acceleration individually on bone tissue kinetics around titanium implants were aimed for in this study. A titanium implant was inserted in the tibia of 120 rats. The rats were divided into 1 control group (no loading) and 5 test groups with low (L), medium (M) or high (H) frequency ranges and accelerations [12–30 Hz at 0.3×g (FLAH); 70–90 Hz at 0.075×g (FMAM); 70–90 Hz at 0.3×g (FMAH); 130–150 Hz at 0.043×g (FHAL); 130–150 Hz at 0.3×g (FHAH)]. WBV was applied for 1 or 4 weeks. Implant osseointegration was evaluated by quantitative histology (bone-to-implant contact (BIC) and peri-implant bone formation (BV/TV)). A 2-way ANOVA (duration of experimental period; loading mode) with α = 0.05 was performed. BIC significantly increased over time and under load (p < 0.0001). The highest BICs were found for loading regimes at high acceleration with medium or high frequency (FMAH and FHAH), and significantly differing from FLAH and FMAM (p < 0.02 and p < 0.005 respectively). BV/TV significantly decreased over time (p < 0.0001). Loading led to a site-specific BV/TV increase (p < 0.001). The highest BV/TV responses were found for FMAH and FHAH, significantly differing from FMAM (p < 0.005). The findings reveal the potential of high-frequency vibration loading to accelerate and enhance implant osseointegration, in particular when applied at high acceleration. Such mechanical signals hold great, though untapped, potential to be used as non-pharmacologic treatment for improving implant osseointegration in compromised bone.
引用
收藏
页码:467 / 475
页数:8
相关论文
共 50 条
  • [41] COMPARISON OF ARTIFICIAL-RESPIRATION BY HIGH-FREQUENCY OSCILLATIONS APPLIED THROUGH THE TRACHEAL AND PERITHORACIC PASSAGES IN THE RAT
    HARF, A
    BERTRAND, C
    TEISSEIRE, B
    CHANG, HK
    JOURNAL DE PHYSIOLOGIE, 1982, 78 (05): : A15 - A15
  • [42] High-frequency vibration analysis of thin elastic plates under heavy fluid loading by an energy finite element formulation
    Zhang, WG
    Wang, AM
    Vlahopoulos, N
    Wu, KC
    JOURNAL OF SOUND AND VIBRATION, 2003, 263 (01) : 21 - 46
  • [43] In situ hydrogen doping of titanium dioxide via PAALD for enhanced MIM diode performance in high-frequency applications
    Ozyigit, Dogu
    Azer, Bersu Bastug
    Gulsaran, Ahmet
    Shaker, George
    Bajcsy, Michal
    Pope, Michael A.
    Yavuz, Mustafa
    JOURNAL OF MATERIALS CHEMISTRY C, 2025, 13 (07)
  • [44] Sevoflurane Blocks the Induction of Long-term Potentiation When Present during, but Not When Present Only before, the High-frequency Stimulation
    Liu, Jinyang
    Yang, Lie
    Lin, Daisy
    Cottrell, James E.
    Kass, Ira S.
    ANESTHESIOLOGY, 2018, 128 (03) : 555 - 563
  • [45] A fiber Bragg grating acceleration sensor based on a circular flexure hinge structure for medium- and high-frequency vibration measurements
    Le, Hoang-Dang
    Chiang, Chia-Chin
    Nguyen, Chi-Ngon
    Hsu, Hsiang-Cheng
    OPTIK, 2023, 280
  • [46] Hydrophobic Coating Platforms for High-Efficiency Loading and Direct Transmembrane Delivery of Fat-Soluble Osteogenic Drug for Enhanced Osseointegration of Titanium Implants
    Chen, Yicheng
    Ning, Xiaona
    Jia, Xuelian
    Xin, He
    Kong, Shaolingzhuo
    Wu, Ben
    Ding, Tiexin
    Zhu, Simin
    Ren, Xiaomin
    Zhang, Xiao
    Lu, Zihan
    Zhang, Yufan
    Zhang, Wenhui
    Zhang, Yu
    Kong, Liang
    Wang, Guocheng
    Liu, Fuwei
    ADVANCED FUNCTIONAL MATERIALS, 2024, 34 (18)
  • [47] Fast increase in ductility and strength of Zr-based bulk amorphous alloys induced by intermittent high-frequency vibration loading
    Lou, Yan
    Yang, Lingyun
    Xv, Shenpeng
    Ma, Jiang
    INTERMETALLICS, 2022, 142
  • [48] Enhanced sensitivity and linear-response in iontronic pressure sensors for non-contact, high-frequency vibration recognition
    Su, Daojian
    Shen, Gengzhe
    Li, Junxian
    Qin, Bolong
    Wang, Shuangpeng
    Yang, Weijia
    He, Xin
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2024, 659 : 1042 - 1051
  • [49] The effects of training through high-frequency electrical stimulation on the physiological properties of single human thenar motor units
    Chan, KM
    Andres, LP
    Polykovskaya, Y
    Brown, WF
    MUSCLE & NERVE, 1999, 22 (02) : 186 - 195
  • [50] Study of Changes in the Current–Voltage Characteristics of a Semiconductor Diode When Powerful High-Frequency Signals Pass Through It
    A. V. Semenov
    A. V. Serov
    K. V. Shibalko
    Journal of Communications Technology and Electronics, 2021, 66 : 206 - 210