FDG-PET standardized uptake values in normal anatomical structures using iterative reconstruction segmented attenuation correction and filtered back-projection

被引:0
|
作者
Celso D. Ramos
Yusuf E. Erdi
Mithat Gonen
Elyn Riedel
Henry W. D. Yeung
Homer A. Macapinlac
Roland Chisin
Steven M. Larson
机构
[1] Department of Radiology,
[2] Nuclear Medicine Service,undefined
[3] Memorial Sloan-Kettering Cancer Center,undefined
[4] New York,undefined
[5] USA,undefined
[6] Division of Nuclear Medicine,undefined
[7] Department of Radiology,undefined
[8] School of Medical Sciences,undefined
[9] Campinas State University,undefined
[10] PO Box 6111,undefined
[11] 13083-970,undefined
[12] Campinas-SP,undefined
[13] Brazil,undefined
[14] Department of Medical Physics,undefined
[15] Memorial Sloan-Kettering Cancer Center,undefined
[16] New York,undefined
[17] USA,undefined
[18] Department of Epidemiology and Biostatistics,undefined
[19] Memorial Sloan-Kettering Cancer Center,undefined
[20] New York,undefined
[21] USA,undefined
[22] Department of Medical Biophysics and Nuclear Medicine,undefined
[23] Hadassah Hebrew University Hospital,undefined
[24] Jerusalem,undefined
[25] Israel,undefined
来源
关键词
Standardized uptake value Positron emission tomography Fluorodeoxyglucose Iterative reconstruction Normal structures;
D O I
暂无
中图分类号
学科分类号
摘要
Filtered back-projection (FBP) is the most commonly used reconstruction method for PET images, which are usually noisy. The iterative reconstruction segmented attenuation correction (IRSAC) algorithm improves image quality without reducing image resolution. The standardized uptake value (SUV) is the most clinically utilized quantitative parameter of [fluorine-18]fluoro-2-deoxy-D-glucose (FDG) accumulation. The objective of this study was to obtain a table of SUVs for several normal anatomical structures from both routinely used FBP and IRSAC reconstructed images and to compare the data obtained with both methods. Twenty whole-body PET scans performed in consecutive patients with proven or suspected non-small cell lung cancer were retrospectively analyzed. Images were processed using both IRSAC and FBP algorithms. Nonquantitative or gaussian filters were used to smooth the transmission scan when using FBP or IRSAC algorithms, respectively. A phantom study was performed to evaluate the effect of different filters on SUV. Maximum and average SUVs (SUVmax and SUVavg) were calculated in 28 normal anatomical structures and in one pathological site. The phantom study showed that the use of a nonquantitative smoothing filter in the transmission scan results in a less accurate quantification and in a 20% underestimation of the actual measurement. Most anatomical structures were identified in all patients using the IRSAC images. On average, SUVavg and SUVmax measured on IRSAC images using a gaussian filter in the transmission scan were respectively 20% and 8% higher than the SUVs calculated from conventional FBP images. Scatterplots of the data values showed an overall strong relationship between IRSAC and FBP SUVs. Individual scatterplots of each site demonstrated a weaker relationship for lower SUVs and for SUVmax than for higher SUVs and SUVavg. A set of reference values was obtained for SUVmax and SUVavg of normal anatomical structures, calculated with both IRSAC and FBP image reconstruction algorithms. The use of IRSAC and a gaussian filter for the transmission scan seems to give more accurate SUVs than are obtained from conventional FBP images using a nonquantitative filter for the transmission scan.
引用
收藏
页码:155 / 164
页数:9
相关论文
共 37 条
  • [1] FDG-PET standardized uptake values in normal anatomical structures using iterative reconstruction segmented attenuation correction and filtered back-projection
    Ramos, CD
    Erdi, YE
    Gonen, M
    Riedel, E
    Yeung, HWD
    Macapinlac, HA
    Chisin, R
    Larson, SM
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (02) : 155 - 164
  • [2] FDG-PET standardized uptake values (SUVs) in normal anatomical structures using iterative reconstruction segmented attenuation correction (IRSAC) and filtered back projection (FBP).
    Ramos, CD
    Erdi, YE
    Gonen, M
    Riedel, E
    Yeung, HW
    Macapinlac, HA
    Chisin, R
    Larson, SM
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 282P - 282P
  • [3] The influence of filtered back-projection and iterative reconstruction on partial volume correction in PET
    Kops, ER
    Krause, BJ
    [J]. NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2005, 44 (03): : 99 - 106
  • [4] A comparison of reconstruction algorithms with FDG PET. Iterative reconstruction segmented attenuation correction (IRSAC) allows greater detectability than filtered back projection (FBP).
    Akhurst, T
    Erdi, Y
    Colsher, J
    Crandall, P
    MacApinlac, H
    Humm, J
    Yeung, H
    Larson, SM
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (09): : 1027 - 1027
  • [5] Comparison of SUV obtained from filtered back projection with measured attenuation correction and iterative reconstruction with segmented attenuation correction.
    Kim, CK
    Chun, H
    Almeida, O
    Krynyckyi, BR
    Knesaurek, K
    Machac, J
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 62P - 62P
  • [6] Clinical significance of quantitative differences in FDG lymph node uptake during early HIV infection: Iterative reconstruction with segmented attenuation correction versus filtered back projection with measured attenuation correction.
    Chin, B
    Iyengar, S
    Schwartz, D
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 192P - 193P
  • [7] Evaluation of iterative reconstruction (OSEM) versus filtered back-projection for the assessment of myocardial glucose uptake and myocardial perfusion using dynamic PET
    Hanne M. Søndergaard
    Mette Marie Madsen
    Karin Boisen
    Morten Bøttcher
    Ole Schmitz
    Torsten T. Nielsen
    Hans Erik Bøtker
    Søren B. Hansen
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 320 - 329
  • [8] Evaluation of iterative reconstruction (OSEM) versus filtered back-projection for the assessment of myocardial glucose uptake and myocardial perfusion using dynamic PET
    Sondergaard, Hanne M.
    Madsen, Mette Marie
    Boisen, Karin
    Bottcher, Morten
    Schmitz, Ole
    Nielsen, Torsten T.
    Botker, Hans Erik
    Hansen, Soren B.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (03) : 320 - 329
  • [9] FDG-PET of patients with suspected renal failure: standardized uptake values in normal tissues
    Ryogo Minamimoto
    Nobukazu Takahashi
    Tomio Inoue
    [J]. Annals of Nuclear Medicine, 2007, 21
  • [10] FDG-PET of patients with suspected renal failure: standardized uptake values in normal tissues
    Minamimoto, Ryogo
    Takahashi, Nobukazu
    Inoue, Tomio
    [J]. ANNALS OF NUCLEAR MEDICINE, 2007, 21 (04) : 217 - 222