Investigation of contrast-enhanced subtracted breast CT images with MAP-EM based on projection-based weighting imaging

被引:0
|
作者
Zhengdong Zhou
Shaolin Guan
Runchao Xin
Jianbo Li
机构
[1] Nanjing University of Aeronautics and Astronautics,State Key Laboratory of Mechanics and Control of Mechanical Structures
[2] Nanjing University of Aeronautics and Astronautics,Department of Nuclear Science and Engineering
关键词
Photon counting detector; Projection-based weighting; Contrast-enhanced subtracted breast computer tomography (CESBCT); Maximum a posteriori expectation maximization algorithm;
D O I
暂无
中图分类号
学科分类号
摘要
Contrast-enhanced subtracted breast computer tomography (CESBCT) images acquired using energy-resolved photon counting detector can be helpful to enhance the visibility of breast tumors. In such technology, one challenge is the limited number of photons in each energy bin, thereby possibly leading to high noise in separate images from each energy bin, the projection-based weighted image, and the subtracted image. In conventional low-dose CT imaging, iterative image reconstruction provides a superior signal-to-noise compared with the filtered back projection (FBP) algorithm. In this paper, maximum a posteriori expectation maximization (MAP-EM) based on projection-based weighting imaging for reconstruction of CESBCT images acquired using an energy-resolving photon counting detector is proposed, and its performance was investigated in terms of contrast-to-noise ratio (CNR). The simulation study shows that MAP-EM based on projection-based weighting imaging can improve the CNR in CESBCT images by 117.7%–121.2% compared with FBP based on projection-based weighting imaging method. When compared with the energy-integrating imaging that uses the MAP-EM algorithm, projection-based weighting imaging that uses the MAP-EM algorithm can improve the CNR of CESBCT images by 10.5%–13.3%. In conclusion, MAP-EM based on projection-based weighting imaging shows significant improvement the CNR of the CESBCT image compared with FBP based on projection-based weighting imaging, and MAP-EM based on projection-based weighting imaging outperforms MAP-EM based on energy-integrating imaging for CESBCT imaging.
引用
收藏
页码:371 / 377
页数:6
相关论文
共 50 条
  • [31] Contrast-Enhanced Ultrasound Imaging Based on Bubble Region Detection
    Huang, Yurong
    Yu, Jinhua
    Tong, Yusheng
    Li, Shuying
    Chen, Liang
    Wang, Yuanyuan
    Zhang, Qi
    APPLIED SCIENCES-BASEL, 2017, 7 (10):
  • [32] Malignant lesion segmentation in contrast-enhanced breast MR images based on the marker-controlled watershed
    Cui, Yunfeng
    Tan, Yongqiang
    Zhao, Binsheng
    Liberman, Laura
    Parbhu, Rakesh
    Kaplan, Jennifer
    Theodoulou, Maria
    Hudis, Clifford
    Schwartz, Lawrence H.
    MEDICAL PHYSICS, 2009, 36 (10) : 4359 - 4369
  • [33] Diffusion-weighted imaging or dynamic contrast-enhanced curve: a retrospective analysis of contrast-enhanced magnetic resonance imaging–based differential diagnoses of benign and malignant breast lesions
    Xiaoping Yang
    Mengshi Dong
    Shu Li
    Ruimei Chai
    Zheng Zhang
    Nan Li
    Lina Zhang
    European Radiology, 2020, 30 : 4795 - 4805
  • [34] Convolutional neural network-based automatic liver delineation on contrast-enhanced and non-contrast-enhanced CT images for radiotherapy planning
    Sakashita, Naohiro
    Shirai, Kiyonori
    Ueda, Yoshihiro
    Ono, Ayuka
    Teshima, Teruki
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (06) : 981 - 986
  • [36] Computer-aided diagnosis in contrast-enhanced CT colonography: an approach based on contrast
    Luboldt, W
    Mann, C
    Tryon, CL
    Vonthein, R
    Stueker, D
    Kroll, M
    Luz, O
    Claussen, CD
    Vogl, TJ
    EUROPEAN RADIOLOGY, 2002, 12 (09) : 2236 - 2241
  • [37] Automated mass detection in contrast-enhanced CT colonography: an approach based on contrast and volume
    Luboldt, W
    Tryon, C
    Kroll, M
    Toussaint, TL
    Holzer, K
    Hoepffner, N
    Vogl, TJ
    EUROPEAN RADIOLOGY, 2005, 15 (02) : 247 - 253
  • [38] Automated mass detection in contrast-enhanced CT colonography: an approach based on contrast and volume
    W. Luboldt
    C. Tryon
    M. Kroll
    T. L. Toussaint
    K. Holzer
    N. Hoepffner
    T. J. Vogl
    European Radiology, 2005, 15 : 247 - 253
  • [39] Computer-aided diagnosis in contrast-enhanced CT colonography: an approach based on contrast
    Wolfgang Luboldt
    Carolin Mann
    Cathy L. Tryon
    Reinhard Vonthein
    Dietmar Stueker
    Manuela Kroll
    Oliver Luz
    Claus D. Claussen
    Thomas J. Vogl
    European Radiology, 2002, 12 : 2236 - 2241
  • [40] TUMOR DELINEATION WITH A PROBABILITY FUNCTION BASED ON DYNAMIC CONTRAST-ENHANCED CT
    Korporaal, J.
    van den Berg, N.
    Groenendaal, G.
    Moman, M.
    van Vulpen, M.
    van der Heide, U.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S81 - S81