A new dynamic myocardial phantom for the assessment of left ventricular function by gated single-photon emission tomography

被引:0
|
作者
Naoki Kubo
Koichi Morita
Chietsugu Katoh
Tohru Shiga
Masanori Konno
Eriko Tsukamoto
Yutaka Morita
Nagara Tamaki
机构
[1] Department of Radiological Technology,
[2] College of Medical Technology,undefined
[3] Hokkaido University,undefined
[4] Sapporo,undefined
[5] Department of Nuclear Medicine,undefined
[6] School of Medicine,undefined
[7] Hokkaido University,undefined
[8] Sapporo,undefined
[9] Department of Tracer Kinetics,undefined
[10] Hokkaido University,undefined
[11] Sapporo,undefined
[12] Correspondence to: Department of Nuclear Medicine,undefined
[13] School of Medicine,undefined
[14] Hokkaido University,undefined
[15] Kita-15,undefined
[16] Nishi-7,undefined
[17] Kita-ku,undefined
[18] Sapporo 060–8638,undefined
来源
关键词
Myocardium Phantom Wall motion Single-photon emission tomography;
D O I
暂无
中图分类号
学科分类号
摘要
Gated myocardial perfusion single-photon emission tomography (SPET) has been used for the measurement of left ventricular (LV) function and validated by means of comparison with other imaging modalities. We have designed a new dynamic myocardial phantom in order to validate the LV function as assessed by the use of gated myocardial perfusion SPET. The phantom consists of two half-ellipsoids (an endocardial surface and an epicardial surface) and a thorax. The myocardial space is filled with a radioactive solution. The endocardial surface moves continuously towards and away from the epicardial surface in the longitudinal axis to vary the LV volume [143 ml at end-diastole (ED), 107 ml at end-systole (ES)] and thickness (apex 8 mm at ED and 26 mm at ES, midplane 8 mm). The mean values of wall motion (WM) for the apical midplane region and the basal midplane region were 5 mm and 2 mm, respectively. Gated myocardial SPET was performed during 8 and 16 intervals. These projection data sets were processed using a Butterworth filter with an order of 5 and a critical frequency of 0.34 cycles/cm. LV function was calculated using the quantitative gated SPET (QGS) algorithm. The LV function values estimated by gated SPET during 16 intervals [22% for ejection fraction (EF), 3.7 mm for WM of the apical midplane, 1.7 mm for WM of the basal midplane] closely resembled actual LV functions [25% for EF, 5 mm for WM of the apical midplane, 2 mm for WM of the basal midplane]. However, the estimated values during 8 intervals were smaller than those during 16 intervals (19% for EF, 3.3 mm for WM of the apical-midplane, 1.1 mm for WM of the basal-midplane). The estimated LV volumes closely correlated with the actual volumes (r=0.99 for 16 intervals, r=0.95 for 8 intervals). Utilizing this phantom, LV function estimated using gated myocardial SPET can be compared with actual values.
引用
收藏
页码:1525 / 1530
页数:5
相关论文
共 50 条
  • [31] Aortic valve calcium is associated with left ventricular diastolic function in patients without evidence of ischaemic heart disease: assessment by gated single-photon emission computed tomography
    Nitta, Kazuhiro
    Kurisu, Satoshi
    Erasta, Ramandika
    Ikenaga, Hiroki
    Ishibashi, Ken
    Fukuda, Yukihiro
    Kihara, Yasuki
    ACTA CARDIOLOGICA, 2021, 76 (04) : 359 - 364
  • [32] ASSESSMENT OF SYSTOLIC THICKENING WITH TL-201 ECG-GATED SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY - A PARAMETER FOR LOCAL LEFT-VENTRICULAR FUNCTION
    MOCHIZUKI, T
    MURASE, K
    FUJIWARA, Y
    TANADA, S
    HAMAMOTO, K
    TAUXE, WN
    JOURNAL OF NUCLEAR MEDICINE, 1991, 32 (08) : 1496 - 1500
  • [33] Assessment of left ventricular dyssynchrony in patients with coronary artery disease during adenosine stress using ECG-gated myocardial perfusion single-photon emission computed tomography
    Horigome, Miki
    Yamazaki, Kyohei
    Ikeda, Uichi
    NUCLEAR MEDICINE COMMUNICATIONS, 2010, 31 (10) : 864 - 873
  • [34] Quality of myocardial perfusion single-photon emission tomography imaging: multicentre evaluation with a cardiac phantom
    Heikkinen, J
    Ahonen, A
    Kuikka, JT
    Rautio, P
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (10) : 1289 - 1297
  • [35] Quality of myocardial perfusion single-photon emission tomography imaging: Multicentre evaluation with a cardiac phantom
    Heikkinen, Jari
    Ahonen, Aapo
    Kuikka, Jyrki T.
    Rautio, Pentti
    European Journal of Nuclear Medicine and Molecular Imaging, 1999, 26 (10): : 1289 - 1297
  • [36] Quality of myocardial perfusion single-photon emission tomography imaging: multicentre evaluation with a cardiac phantom
    Jari Heikkinen
    Aapo Ahonen
    Jyrki T. Kuikka
    Pentti Rautio
    European Journal of Nuclear Medicine, 1999, 26 : 1289 - 1297
  • [37] QUANTITATIVE-ANALYSIS OF LEFT-VENTRICULAR FUNCTION USING GATED SINGLE PHOTON-EMISSION TOMOGRAPHY
    BARAT, JL
    BRENDEL, J
    COLLE, JP
    MAGIMELPELONNIER, V
    OHAYON, J
    WYNCHANK, S
    LECCIA, F
    BESSE, P
    DUCASSOU, D
    JOURNAL OF NUCLEAR MEDICINE, 1984, 25 (11) : 1167 - 1174
  • [38] Validation of quantitative gated single photon emission computed tomography and an automated scoring system for the assessment of regional left ventricular systolic function
    Hashimoto, A
    Nakata, T
    Wakabayashi, T
    Kyuma, M
    Takahashi, T
    Tsuchihashi, K
    Shimamoto, K
    NUCLEAR MEDICINE COMMUNICATIONS, 2002, 23 (09) : 887 - 898
  • [39] Gated single-photon emission tomography imaging protocol to evaluate myocardial stunning after exercise
    Hashimoto, J
    Kubo, A
    Iwasaki, R
    Iwanaga, S
    Mitamura, H
    Ogawa, S
    Kosuda, S
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (12) : 1541 - 1546
  • [40] Gated single-photon emission tomography imaging protocol to evaluate myocardial stunning after exercise
    Jun Hashimoto
    Atsushi Kubo
    Ryuichiro Iwasaki
    Shiro Iwanaga
    Hideo Mitamura
    Satoshi Ogawa
    Shigeru Kosuda
    European Journal of Nuclear Medicine, 1999, 26 : 1541 - 1546