The variability of 2D and 3D transthoracic echocardiography applied in a general populationIntermodality, inter- and intraobserver variability

被引:0
|
作者
Filip Lyng Lindgren
Bhupendar Tayal
Kristian Bundgaard Ringgren
Peter Ascanius Jacobsen
Kristian Hay Kragholm
Tomas Zaremba
Niels Holmark Andersen
Rasmus Møgelvang
Tor Biering-Sørensen
Andreas Hagendorff
Peter Schnohr
Gorm Jensen
Peter Søgaard
机构
[1] Aalborg University Hospital,Department of Cardiology
[2] Aalborg University,Clinical Institute
[3] Aalborg University Hospital,Department of Respiratory Diseases
[4] Rigshospitalet,Centre for Cardiac, Vascular, Pulmonary and Infectious Diseases
[5] Herlev and Gentofte Hospital,Cardiovascular Non
[6] Herlev and Gentofte Hospital,Invasive Imaging Research Laboratory, Department of Cardiology
[7] University of Leipzig,Department of Cardiology
[8] Frederiksberg Hospital,Laboratory of Echocardiography, Department of Cardiology
关键词
Cardiac imaging techniques; Left ventricular function; Heart failure; Health surveys; Urban population;
D O I
暂无
中图分类号
学科分类号
摘要
Assessment of the left ventricular (LV) function by three-dimensional echocardiography (3DE) is potentially superior to 2D echo echocardiography (2DE) for LV performance assessment. However, intra- and interobserver variation needs further investigation. We examined the intra- and interobserver variability between 2 and 3DE in a general population. In total, 150 participants from the Copenhagen City Heart Study were randomly chosen. Two observers assessed left ventricular ejection fraction (LVEF), end-diastolic (EDV) and end-systolic volumes (ESV) by 2DE and 3DE. Inter-, intraobserver and intermodality variabilities are presented as means of difference (MD), limits of agreement (LoA), coefficient of correlation (r), intraclass correlation coefficients (ICC). The lowest MD and LoA and highest r- and ICC-values was generally seen among the 3D acquisitions, with the 3D EDV interobserver as the best performing estimate (r = 0.95, ICC = 0.94). The largest MD, LoA and lowest r- and ICC-values was found in the interobserver 2D LVEF (r = 0.76, ICC = 0.63. For the intraobserver analysis, there were statistically significant differences between observations for all but 3DE EDV (p = 0.06). For interobserver analysis, there were statistically significant differences between observers for all estimates but 2DE EDV (p = 0.11), 3D ejection fraction (p = 0.9), 3DE EDV (p = 0.11) and 3D ESV (p = 0.15). Three-dimensional echocardiography is more robust and reproducible than 2DE and should be preferred for assessment of LV function.
引用
收藏
页码:2177 / 2190
页数:13
相关论文
共 50 条
  • [21] "3D Fusion" Echocardiography Improves 3D Left Ventricular Assessment: Comparison with 2D Contrast Echocardiography
    Augustine, Daniel
    Yaqub, Mohammad
    Szmigielski, Cezary
    Lima, Eduardo
    Petersen, Steffen E.
    Becher, Harald
    Noble, J. Alison
    Leeson, Paul
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (02): : 302 - 309
  • [22] Feasibility of Various Aortic Valve Area Calculations Using 3D Transoesophageal Echocardiography and 2D Transthoracic Echocardiography in Patients with Aortic Stenosis
    Rahman, E. Abdul
    Khir, R. Najme
    Othman, N.
    Chuah, S. C.
    Ibrahim, K. S.
    Lim, C. W.
    Arshad, M. K. Mohd
    Ibrahim, Z. O.
    Ismail, J. R.
    Abidin, H. A. Zainal
    Kasim, S. S.
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 249 : S39 - S39
  • [23] 2D and 3D speckle tracking echocardiography: clinical application
    Szymczyk, Ewa
    Lipiec, Piotr
    Michalski, Blazej
    Kasprzak, Jaroslaw D.
    [J]. KARDIOLOGIA POLSKA, 2013, 71 (01) : 77 - 83
  • [24] Inter- and intra observer variability of global left ventriculair 2D strain in comparison to left ventricular ejection fraction
    Dumoulein, M.
    Kuznetsova, T.
    Staessen, J.
    Voigt, J. U.
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 : 1070 - 1070
  • [25] Is 3D echocardiography superior to 2D echocardiography in general practice? A systematic review of studies published between 2007 and 2012
    Ruddox, Vidar
    Mathisen, Mariann
    Baekkevar, Morten
    Aune, Erlend
    Edvardsen, Thor
    Otterstad, Jan Erik
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (02) : 1306 - 1315
  • [26] Can 3D transthoracic echocardiography replace conventional 2D transoesophageal in the preoperative assessment of the mitral valve for surgical repair?
    Rana, B. S.
    Wendler, O.
    Desai, J.
    El-Gamel, A.
    Pearson, P.
    Bhan, A.
    Monaghan, M. J.
    [J]. EUROPEAN HEART JOURNAL, 2007, 28 : 395 - 395
  • [27] Segmentation of hippocampal shape: Improved reliability by 2D and 3D visualization of segmented objects and of intra-/inter-rater variability
    Gerig, G
    Jomier, M
    Chakos, MH
    Lieberman, JA
    [J]. SCHIZOPHRENIA RESEARCH, 2001, 49 (1-2) : 154 - 155
  • [28] Colorectal Cancer Patient-Derived 2D and 3D Models Efficiently Recapitulate Inter- and Intratumoral Heterogeneity
    Zhao, Yuanyuan
    Zhang, Bing
    Ma, Yiming
    Zhao, Fuqiang
    Chen, Jianan
    Wang, Bingzhi
    Jin, Hua
    Zhou, Fulai
    Guan, Jiawei
    Zhao, Qian
    Wang, Hongying
    Liu, Qian
    Zhao, Fangqing
    Wang, Xia
    [J]. ADVANCED SCIENCE, 2022, 9 (22)
  • [29] 2D and 3D MHD simulations of disk accretion by rotating magnetized stars: Search for variability
    Romanova, Marina M.
    Kulkarni, Akshay
    Long, Min
    Lovelace, Richard V. E.
    Wick, Justin V.
    Ustyugova, Galina V.
    Koldoba, Alexander V.
    [J]. ADVANCES IN SPACE RESEARCH, 2006, 38 (12) : 2887 - 2892
  • [30] Variability and asymmetry in the shape of the spiny dogfish vagina revealed by 2D and 3D geometric morphometrics
    Hedrick, B. P.
    Antalek-Schrag, P.
    Conith, A. J.
    Natanson, L. J.
    Brennan, P. L. R.
    [J]. JOURNAL OF ZOOLOGY, 2019, 308 (01) : 16 - 27