Visual and rapid detection of Acinetobacter baumannii by a multiple cross displacement amplification combined with nanoparticles-based biosensor assay

被引:0
|
作者
Xueqin Cheng
Jing Yang
Meifang Wang
Peng Wu
Qiong Du
Jinjuan He
Yijun Tang
机构
[1] Taihe Hospital,Department of Respiratory and Critical Medical
[2] Hubei University of Medicine,Department of Clinical Laboratory
[3] Taihe Hospital,Department of Pharmacy
[4] Hubei University of Medicine,undefined
[5] Wuhan General Hospital of the Chinese People’s Liberation Army,undefined
来源
AMB Express | / 9卷
关键词
Multiple cross displacement amplification; Lateral flow biosensor; MCDA-LFB; Detection limit;
D O I
暂无
中图分类号
学科分类号
摘要
The traditional microbiological methods used for detecting Acinetobacter baumannii were usually time-consuming and labor-intensive. Thus, we sought to establish a novel rapid detecting method for target pathogen. A set of multiple cross displacement amplification (MCDA) primers was designed to recognize 10 different regions of the pgaD gene, which was conservative and specific for the bacterium. In the MCDA system, amplification primers D1 and R1 were 5′-labeled with FITC (fluorescein) and biotin, respectively. Numerous FITC- and biotin-attached duplex amplicons were formed during the amplification stage, which were detected by nanoparticles-based lateral flow biosensors (LFB) through immunoreactions (FITC on the duplex and anti-FITC on the LFB test line) and biotin/streptavidin interaction (biotin on the duplex and streptavidin on the nanoparticles). The results showed that the optimized reaction condition of MCDA-LFB method was 62 °C within 25 min. There was no cross reaction with non-A. baumannii species and the non-Acinetobacter genera, and the detection limit for DNA samples was 100 fg/reaction. For 135 sputum samples, the detection results showed that the detection ability of MCDA-LFB assay was superior to the culture methods and conventional PCR. Therefore, MCDA-LFB assay could be a potential tool for the rapid detection of A. baumannii in clinical samples and low resource areas.
引用
收藏
相关论文
共 50 条
  • [31] Highly sensitive and rapid identification of coxsackievirus A16 based on reverse transcription multiple cross displacement amplification combined with nanoparticle-based lateral flow biosensor assay
    Cheng, Jinzhi
    Wang, Yu
    Zhou, Yuhong
    Lu, Jingrun
    Tang, Xiaomin
    FRONTIERS IN MICROBIOLOGY, 2023, 14
  • [32] Development and Application of a Multiple Cross Displacement Amplification Combined With Nanoparticle-Based Lateral Flow Biosensor Assay to Detect Candida tropicalis
    Wang, Yu
    Zhao, Xue
    Cheng, Jinzhi
    Tang, Xiaomin
    Chen, Xu
    Yu, Honglan
    Li, Shijun
    FRONTIERS IN MICROBIOLOGY, 2021, 12
  • [33] A Rapid Detection of Haemophilus influenzae Using Multiple Cross Displacement Amplification Linked With Nanoparticle-Based Lateral Flow Biosensor
    Cao, Qilong
    Liang, Shaoshuai
    Wang, Lin
    Cao, Jun
    Liu, Mengyang
    Li, Shengpeng
    Cao, Xiaolong
    Guo, Yan
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2021, 11
  • [34] Rapid detection of viable Acinetobacter baumannii and antibiotic susceptibility testing based on a phage amplification-Taqman qPCR assay
    Luo, Jun
    Zhang, Xueping
    Liu, Min
    Ai, Wen
    Zheng, Xiaoling
    Liu, Shaowei
    Han, Lu
    Huang, Kuo
    Wan, Jiang
    Luo, Chunhua
    MICROCHEMICAL JOURNAL, 2023, 195
  • [35] Two target genes based multiple cross displacement amplification combined with a lateral flow biosensor for the detection of Mycobacterium tuberculosis complex
    Huang, Junfei
    Xiao, Ziyu
    Yang, Xinggui
    Chen, Xu
    Wang, Xiaojuan
    Chen, Yijiang
    Zheng, Wenlin
    Chen, Wei
    Chen, Huijuan
    Li, Shijun
    BMC MICROBIOLOGY, 2021, 21 (01)
  • [36] Two target genes based multiple cross displacement amplification combined with a lateral flow biosensor for the detection of Mycobacterium tuberculosis complex
    Junfei Huang
    Ziyu Xiao
    Xinggui Yang
    Xu Chen
    Xiaojuan Wang
    Yijiang Chen
    Wenlin Zheng
    Wei Chen
    Huijuan Chen
    Shijun Li
    BMC Microbiology, 21
  • [37] Highly Sensitive and Rapid Identification ofStreptococcus agalactiaeBased on Multiple Cross Displacement Amplification Coupled With Lateral Flow Biosensor Assay
    Cheng, Xueqin
    Dou, Zhiqian
    Yang, Jing
    Gu, Yulong
    Liu, Dexi
    Xie, Ling
    Ren, Tao
    Liu, Yan
    Yu, Zhifang
    Tang, Yijun
    Wang, Meifang
    FRONTIERS IN MICROBIOLOGY, 2020, 11
  • [38] Development of multiple cross displacement amplification label-based gold nanoparticles lateral flow biosensor for detection of Listeria monocytogenes
    Wang, Yi
    Li, Hui
    Wang, Yan
    Li, Hui
    Luo, Lijuan
    Xu, Jianguo
    Ye, Changyun
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2017, 12 : 473 - 486
  • [39] Real-time multiple cross displacement amplification assay for rapid and sensitive detection of Haemophilus influenzae
    Sun, Chunrong
    Jia, Nan
    Huang, Xiaolan
    Xiao, Fei
    Zhou, Juan
    Zhang, Yu
    Fu, Jin
    Xu, Zheng
    Qu, Dong
    Cui, Xiaodai
    Wang, Yi
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2022, 12
  • [40] Sensitive And Rapid Detection Of Acinetobacter Baumannii Based On Loop-Mediated Isothermal Amplification
    Bai, C.
    Li, P.
    Niu, W.
    Yuan, X.
    Liu, H.
    Qin, Y.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191