Visual and rapid detection of Acinetobacter baumannii by a multiple cross displacement amplification combined with nanoparticles-based biosensor assay

被引:0
|
作者
Xueqin Cheng
Jing Yang
Meifang Wang
Peng Wu
Qiong Du
Jinjuan He
Yijun Tang
机构
[1] Taihe Hospital,Department of Respiratory and Critical Medical
[2] Hubei University of Medicine,Department of Clinical Laboratory
[3] Taihe Hospital,Department of Pharmacy
[4] Hubei University of Medicine,undefined
[5] Wuhan General Hospital of the Chinese People’s Liberation Army,undefined
来源
AMB Express | / 9卷
关键词
Multiple cross displacement amplification; Lateral flow biosensor; MCDA-LFB; Detection limit;
D O I
暂无
中图分类号
学科分类号
摘要
The traditional microbiological methods used for detecting Acinetobacter baumannii were usually time-consuming and labor-intensive. Thus, we sought to establish a novel rapid detecting method for target pathogen. A set of multiple cross displacement amplification (MCDA) primers was designed to recognize 10 different regions of the pgaD gene, which was conservative and specific for the bacterium. In the MCDA system, amplification primers D1 and R1 were 5′-labeled with FITC (fluorescein) and biotin, respectively. Numerous FITC- and biotin-attached duplex amplicons were formed during the amplification stage, which were detected by nanoparticles-based lateral flow biosensors (LFB) through immunoreactions (FITC on the duplex and anti-FITC on the LFB test line) and biotin/streptavidin interaction (biotin on the duplex and streptavidin on the nanoparticles). The results showed that the optimized reaction condition of MCDA-LFB method was 62 °C within 25 min. There was no cross reaction with non-A. baumannii species and the non-Acinetobacter genera, and the detection limit for DNA samples was 100 fg/reaction. For 135 sputum samples, the detection results showed that the detection ability of MCDA-LFB assay was superior to the culture methods and conventional PCR. Therefore, MCDA-LFB assay could be a potential tool for the rapid detection of A. baumannii in clinical samples and low resource areas.
引用
收藏
相关论文
共 50 条
  • [1] Visual and rapid detection of Acinetobacter baumannii by a multiple cross displacement amplification combined with nanoparticles-based biosensor assay
    Cheng, Xueqin
    Yang, Jing
    Wang, Meifang
    Wu, Peng
    Du, Qiong
    He, Jinjuan
    Tang, Yijun
    AMB EXPRESS, 2019, 9 (1)
  • [2] Development of a multiple cross displacement amplification combined with nanoparticles-based biosensor assay for rapid and sensitive detection of Streptococcus pyogenes
    Dou, Zhiqian
    Xie, Ling
    Gao, Meiling
    Liu, Dexi
    BMC MICROBIOLOGY, 2024, 24 (01)
  • [3] Development of a multiple cross displacement amplification combined with nanoparticles-based biosensor assay for rapid and sensitive detection of Streptococcus pyogenes
    Zhiqian Dou
    Ling Xie
    Meiling Gao
    Dexi Liu
    BMC Microbiology, 24
  • [4] Development of a multiple cross displacement amplification combined with nanoparticles-based biosensor assay to detect Neisseria meningitidis
    Li, Shijun
    Liu, Chunting
    Liu, Ying
    Ma, Qing
    Wang, Yue
    Wang, Yi
    INFECTION AND DRUG RESISTANCE, 2019, 12 : 2077 - 2087
  • [5] Establishment and application of a multiple cross displacement amplification combined with nanoparticles-based biosensor method for the detection of Bordetella pertussis
    Shijun Li
    Chunting Liu
    Ying Liu
    Qing Ma
    Yue Wang
    Yi Wang
    BMC Microbiology, 20
  • [6] Establishment and application of a multiple cross displacement amplification combined with nanoparticles-based biosensor method for the detection ofBordetella pertussis
    Li, Shijun
    Liu, Chunting
    Liu, Ying
    Ma, Qing
    Wang, Yue
    Wang, Yi
    BMC MICROBIOLOGY, 2020, 20 (01)
  • [7] Rapid Detection of Aspergillus fumigatus Using Multiple Cross Displacement Amplification Combined With Nanoparticles-Based Lateral Flow
    Jiang, Luxi
    Li, Xiaomeng
    Gu, Rumeng
    Mu, Deguang
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2021, 11
  • [8] Development and Clinical Validation of Multiple Cross Displacement Amplification Combined With Nanoparticles-Based Biosensor for Detection of Mycobacterium tuberculosis: Preliminary Results
    Jiao, Wei-Wei
    Wang, Yi
    Wang, Gui-Rong
    Wang, Ya-Cui
    Xiao, Jing
    Sun, Lin
    Li, Jie-Qiong
    Wen, Shu-An
    Zhang, Ting-Ting
    Ma, Qi
    Huang, Hai-Rong
    Shen, A-Dong
    FRONTIERS IN MICROBIOLOGY, 2019, 10
  • [9] Rapid, sensitive and reliable detection of Klebsiella pneumoniae by label-free multiple cross displacement amplification coupled with nanoparticles-based biosensor
    Wang, Yi
    Yan, Weiqiang
    Wang, Yan
    Xu, Jianguo
    Ye, Changyun
    JOURNAL OF MICROBIOLOGICAL METHODS, 2018, 149 : 80 - 88
  • [10] Rapid Detection of Brucella spp. and Elimination of Carryover Using Multiple Cross Displacement Amplification Coupled With Nanoparticles-Based Lateral Flow Biosensor
    Li, Shijun
    Liu, Ying
    Wang, Yue
    Wang, Ming
    Liu, Chunting
    Wang, Yi
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2019, 9