Rapid measurement of cavity ringdown absorption spectra with a swept-frequency laser

被引:1
|
作者
Y. He
B.J. Orr
机构
[1] Macquarie University,Centre for Lasers and Applications
来源
Applied Physics B | 2004年 / 79卷
关键词
Laser Frequency; Cavity Length; Free Spectral Range; Memory Depth; Ringdown Time;
D O I
暂无
中图分类号
学科分类号
摘要
A novel cavity ringdown spectrometer, incorporating a miniature continuous-wave swept-frequency laser that is widely tunable, requires less than 1 s to record wide-ranging absorption spectra with high sensitivity in a single rapid sweep of the laser frequency. The free spectral range of the ringdown cavity defines a sampling grid to measure absorbance-dependent ringdown times at successive cavity-resonance frequencies. The spectrometer has a single-ended transmitter-receiver configuration based on retro-reflected optical-heterodyne detection and exploiting fibre-optical telecommunications components. This swept-frequency approach to cavity ringdown spectroscopy yields a simple, low-cost, compact, rugged, versatile instrument for efficient sensing of gases. The performance of the spectrometer is demonstrated by measuring weak near-infrared rovibrational spectra of carbon dioxide gas within the 1.5–1.6 μm wavelength range.
引用
收藏
页码:941 / 945
页数:4
相关论文
共 50 条
  • [31] Frequency domain analysis for laser-locked cavity ringdown spectroscopy
    Boyson, T. K.
    Spence, T. G.
    Calzada, M. E.
    Harb, C. C.
    OPTICS EXPRESS, 2011, 19 (09): : 8092 - 8101
  • [32] Measurement of trace gases by diode laser cavity ringdown spectroscopy.
    Romanini, D
    Kachanov, AA
    Morville, J
    Chenevier, M
    ENVIRONMENTAL SENSING AND APPLICATIONS, 1999, 3821 : 94 - 104
  • [33] MEASUREMENT OF THE SWEPT-FREQUENCY CARRIER-INDUCED FM RESPONSE OF A SEMICONDUCTOR-LASER USING AN INCOHERENT INTERFEROMETRIC-TECHNIQUE
    BANEY, DM
    GALLION, PB
    CHABRAN, C
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1990, 2 (05) : 325 - 327
  • [34] MEASUREMENT OF OPTICAL FIBER TRANSFER FUNCTIONS BY SWEPT-FREQUENCY TECHNIQUE AND DISCUSSION OF FIBER CHARACTERISTICS.
    Kobayashi, Ikutaro
    Koyama, Masaki
    Aoyama, Kohichi
    Electronics and Communications in Japan (English translation of Denshi Tsushin Gakkai Zasshi), 1977, 60 (04): : 126 - 133
  • [35] A swept-frequency measurement of complex permittivity and complex permeability of a columnar specimen inserted in a rectangular waveguide
    Nishikata, Atsuhiro
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2007, 55 (07) : 1554 - 1567
  • [36] Thickness Measurement of Metal Plates Using Swept-Frequency Eddy Current Testing and Impedance Normalization
    Cheng, Weiying
    IEEE SENSORS JOURNAL, 2017, 17 (14) : 4558 - 4569
  • [37] Cavity-ringdown laser absorption spectroscopy of polyatomic radicals in low pressure
    Scherer, J.J.
    Aniolek, K.W.
    Rakestraw, D.J.
    ACS Symposium Series, 720 : 174 - 195
  • [38] INFRARED CAVITY RINGDOWN LASER-ABSORPTION SPECTROSCOPY (IR-CRLAS)
    SCHERER, JJ
    VOELKEL, D
    RAKESTRAW, DJ
    PAUL, JB
    COLLIER, CP
    SAYKALLY, RJ
    OKEEFE, A
    CHEMICAL PHYSICS LETTERS, 1995, 245 (2-3) : 273 - 280
  • [39] MEASUREMENT OF OPTICAL FIBER TRANSFER-FUNCTIONS BY SWEPT-FREQUENCY TECHNIQUE AND DISCUSSION OF FIBER CHARACTERISTICS
    KOBAYASHI, I
    KOYAMA, M
    AOYAMA, K
    ELECTRONICS & COMMUNICATIONS IN JAPAN, 1977, 60 (04): : 126 - 134
  • [40] <bold>Pulsed Cavity Ringdown Laser Absorption Spectroscopy in a Hollow Waveguide</bold>
    Mungas, Greg S.
    Dreyer, Christopher
    2006 IEEE AEROSPACE CONFERENCE, VOLS 1-9, 2006, : 412 - +