A signal-to-noise analysis of multifocal VEP responses: An objective definition for poor records

被引:69
|
作者
Zhang X. [1 ]
Hood D.C. [1 ]
Chen C.S. [1 ]
Hong J.E. [1 ]
机构
[1] Department of Psychology, Schermerhorn Hall, Room 406, Columbia University, New York, NY 10027-7004
关键词
Multifocal; VEP; Visual evoked potential;
D O I
10.1023/A:1015220501743
中图分类号
学科分类号
摘要
Sixty local VEP records, called the multifocal VEP (mfVEP), can be obtained over a wide retinal area. From subject-to-subject, from day-to-day, and from location-to-location, these records can vary in quality presenting a challenge to quantitative analyses. Here three procedures are described for specifying the quality of mfVEP recordings in terms of signal-to-noise ratios. Monocular mfVEPs were recorded in two, 7-min runs. A '2-run signal-to-noise ratio' (2rSNR) was obtained as [RMS(RunA+RunB)]/[RMS(RunA-RunB)]-1, where RMS is the root-mean-square amplitude of the response over the period from 45 to 150 ms (signal window). Two 'noise-window signal-to-noise ratios' were obtained with the same numerator as the 2rSNR but with the denominators based upon the RMS of a signal-free window from 325 to 430 ms. In one case, inSNR, the denominator was the RMS of the record's noise window and in the other case, mnSNR, the denominator was the mean of the RMS amplitudes of all the signal-free noise windows for the subject. The SNRs were related to false-positive rates (i.e., detecting a signal when none was present) by recording mfVEPs with some of the sectors of the display occluded. In particular, the outer three rings (36 sectors) of the display were occluded so that only noise was recorded; false-positive rates for different values of SNR were calculated. The 2rSNR had the highest false-positive rate largely due to alpha in the records of some subjects. The mnSNR had a lower false-positive rate than did the inSNR because there was little correlation between the RMS of the noise in the signal-free window and the RMS of the noise within the signal window. Use of the mnSNR is recommended over the 2rSNR, especially where alpha contamination can not be eliminated. Ways to improve the SNR of the records are discussed.
引用
收藏
页码:287 / 302
页数:15
相关论文
共 50 条
  • [31] SIGNAL-TO-NOISE RATIO OF THE SINGLE VISUALLY EVOKED-RESPONSES IN MAN
    PEREGRIN, J
    VALACH, M
    PHYSIOLOGIA BOHEMOSLOVACA, 1980, 29 (05): : 462 - 462
  • [32] SIGNAL-TO-NOISE RATIO OF THE BISPECTRAL ANALYSIS OF SPECKLE INTERFEROMETRY
    NAKAJIMA, T
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1988, 5 (09): : 1477 - 1491
  • [33] The signal-to-noise issue in mass spectrometric analysis of polymers
    Chagunda, Ian C.
    Russell, Gregory T.
    McIndoe, J. Scott
    POLYMER CHEMISTRY, 2021, 12 (31) : 4451 - 4461
  • [34] THE EFFECT OF STIMULATION RATE ON THE SIGNAL-TO-NOISE RATIO OF EVOKED-RESPONSES
    AHLFORS, SP
    ILMONIEMI, RJ
    PORTIN, K
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1993, 88 (04): : 339 - 342
  • [35] Definition of signal-to-noise ratio and its critical role in split-beam measurements
    Kieser, R
    Reynisson, P
    Mulligan, TJ
    ICES JOURNAL OF MARINE SCIENCE, 2005, 62 (01) : 123 - 130
  • [36] Utilizing higher order kernels to improve the signal-to-noise ratio of the multifocal visual potential (mfVEP)
    Zhang, X
    Fortune, B
    Hood, DC
    Johnson, CA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [37] A signal-to-noise index to quantify the potential for peak detection in sediment-charcoal records
    Kelly, Ryan F.
    Higuera, Philip E.
    Barrett, Carolyn M.
    Hu, Feng Sheng
    QUATERNARY RESEARCH, 2011, 75 (01) : 11 - 17
  • [38] Noise analysis and signal-to-noise ratio model of gain modulation laser imaging
    Tu Zhipeng
    Li Sining
    Zhang Dayong
    Lu Wei
    AOPC 2015: IMAGE PROCESSING AND ANALYSIS, 2015, 9675
  • [40] Signal-to-noise ratio, signal processing, and spectral information in the instrumental analysis laboratory
    Blitz, JP
    Klarup, DG
    JOURNAL OF CHEMICAL EDUCATION, 2002, 79 (11) : 1358 - 1360