Regional myocardial mechanics: Integrative computational models of flow-function relations

被引:0
|
作者
Andrew D McCulloch
Reza Mazhari
机构
[1] The Whitaker Institute for Biomedical Engineering,Department of Bioengineering
[2] University of California San Diego,Department of Bioengineering
[3] Johns Hopkins Medical School,undefined
来源
关键词
Myocardial mechanics; stress and strain; computational model; myocardial; stunning; ischemic border zone; regional myocardial perfusion;
D O I
暂无
中图分类号
学科分类号
摘要
Many cardiac disorders result in regionally altered myocardial mechanics. Although myocardial strain distributions can be measured experimentally and clinically, regional wall stresses must be computed from computational models. Combining these approaches can provide insight into the structural basis of regional dysfunction under conditions such as acute myocardial infarction and ischemia- reperfusion. Recently, 3- dimensional computational models have helped to elucidate the structural basis of the functional border zone adjacent to acutely ischemic myocardium. They have also shown that heterogeneous dysfunction in ischemicreperfused stunned myocardium does not necessarily imply heterogeneous myofilament injury. Now that computational models are able to reproduce many complex features of the 3- dimensional patterns of regional myocardial deformation observed experimentally, dwe suggest possible roles for such integrative models in clinical diagnosis.
引用
收藏
页码:506 / 519
页数:13
相关论文
共 50 条
  • [21] A computational study of the interaction between coronary blood flow and myocardial mechanics
    Smith, NP
    PHYSIOLOGICAL MEASUREMENT, 2004, 25 (04) : 863 - 877
  • [22] The flow-function relationship in patients with chronic coronary artery disease and reduced regional function: a Doppler transesophageal and bidimensional transthoracic echocardiography study
    Baroni, M
    Torres, MA
    Maffei, S
    Varga, A
    Terrazzi, M
    Biagini, A
    Picano, E
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1999, 15 (04): : 271 - 278
  • [23] The flow-function relationship in patients with chronic coronary artery disease and reduced regional function: a Doppler transesophageal and bidimensional transthoracic echocardiography study
    Monica Baroni
    Marco A. Torres
    Stefano Maffei
    Albert Varga
    Marco Terrazzi
    Andrea Biagini
    Eugenio Picano
    The International Journal of Cardiac Imaging, 1999, 15 : 271 - 278
  • [24] Regional myocardial blood flow and function after coronary microembolisation
    Rose, J
    Leischik, R
    Skyschally, A
    Erbel, R
    Heusch, G
    FASEB JOURNAL, 1997, 11 (03): : 2497 - 2497
  • [25] Balance and imbalance of regional myocardial contractile function and blood flow
    Schulz, R
    Heusch, G
    ZEITSCHRIFT FUR KARDIOLOGIE, 2001, 90 (12): : 964 - 969
  • [26] Balance and imbalance of regional myocardial contractile function and blood flow
    Rainer Schulz
    Gerd Heusch
    Zeitschrift für Kardiologie, 2001, 90 : 964 - 969
  • [27] Regional myocardial blood flow and function after coronary microembolization
    Skyschally, A
    Jalowy, A
    Schulz, R
    Rose, J
    Erbel, R
    Heusch, G
    JOURNAL OF VASCULAR RESEARCH, 1998, 35 (03) : 219 - 219
  • [28] Regional myocardial blood flow and function after coronary microembolisation
    Skyschally, A
    Rose, J
    Leischik, R
    Erbel, R
    Heusch, G
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1997, 433 (06): : O83 - O83
  • [29] A Review of Computational Models for the Flow of Milled Biomass Part II: Continuum-Mechanics Models
    Jin, Wencheng
    Stickel, Jonathan J.
    Xia, Yidong
    Klinger, Jordan
    ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2020, 8 (16): : 6157 - 6172
  • [30] EFFECTS OF SYMPATHOMIMETIC AMINES ON REGIONAL MYOCARDIAL-FUNCTION, FLOW AND ELECTROGRAMS AND PERIPHERAL FLOW DISTRIBUTION IN CONSCIOUS DOGS WITH REGIONAL MYOCARDIAL ISCHEMIA
    VATNER, SF
    BAIG, H
    CLINICAL RESEARCH, 1978, 26 (03): : A548 - A548