Shaping ability of two nickel–titanium instruments activated by continuous rotation or adaptive motion: a micro-computed tomography study

被引:0
|
作者
E. Pedullà
G. Plotino
N. M. Grande
G. Avarotti
G. Gambarini
E. Rapisarda
F. Mannocci
机构
[1] University of Catania,Department of General Surgery and Surgical
[2] “La Sapienza” University of Rome,Medical Specialties
[3] Catholic University of Sacred Heart,C.L.I.D.
[4] “La Sapienza” University of Rome,Department of Endodontics
[5] King’s College London Dental Institute,Department of Conservative Dentistry
来源
关键词
Shaping ability; Micro-computed tomography; Nickel–titanium instruments; Adaptive motion; Continuous rotation;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:2227 / 2233
页数:6
相关论文
共 50 条
  • [41] Effects of three nickel titanium instrument systems on root canal geometry assessed by micro-computed tomography
    Gergi, R.
    Osta, N.
    Bourbouze, G.
    Zgheib, C.
    Arbab-Chirani, R.
    Naaman, A.
    INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (02) : 162 - 170
  • [42] Micro-Computed Tomographic Evaluation of Shaping Ability and Dentinal Microcracks Formation After Using New Heat-Treated Nickel-Titanium Systems
    Al Gamdi, Abdulhakim
    Mathew, Shibu Thomas
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2021, 9 (06): : 246 - 254
  • [43] A comparative evaluation on the cleaning and shaping ability of three nickel titanium rotary instruments using computerized tomography - An ex vivo study
    Narayan, Gopal S.
    Venkatesan, Sokkalingam Mothilal
    Karumaran, C. S.
    Indira, Rajamani
    Ramachandran, S.
    Srinivasan, M. R.
    CONTEMPORARY CLINICAL DENTISTRY, 2012, 3 (06) : 151 - 155
  • [44] Shaping ability of XP-endo Shaper and ProTaper Next in long oval-shaped canals: a micro-computed tomography study
    Velozo, C.
    Silva, S.
    Almeida, A.
    Romeiro, K.
    Vieira, B.
    Dantas, H.
    Sousa, F.
    De Albuquerque, D. S.
    INTERNATIONAL ENDODONTIC JOURNAL, 2020, 53 (07) : 998 - 1006
  • [45] Efficacy of CM-Wire, M-Wire; and Nickel-Titanium Instruments for Removing Filling Material from Curved Root Canals: A Micro-Computed Tomography Study
    Rodrigues, Clarissa Teles
    Hungaro Duarte, Marco Antonio
    de Almeida, Marcela Milanezi
    de Andrade, Flaviana Bombarda
    Bernardineli, Norberti
    JOURNAL OF ENDODONTICS, 2016, 42 (11) : 1651 - 1655
  • [46] Analysis of second mesiobuccal root canal instrumentation in maxillary first molars with three nickel–titanium rotary instruments: a micro-computed tomographic study
    Yuerong Zhang
    Jie Liu
    Yongchun Gu
    Juan Wang
    Hai Xu
    Guangdong Zhang
    Odontology, 2021, 109 : 496 - 505
  • [47] Effects of Two Nickel-Titanium Instrument Systems, Mtwo versus ProTaper Universal, on Root Canal Geometry Assessed by Micro-Computed Tomography
    Yang, Guobin
    Yuan, Guohua
    Yun, Xiaofei
    Zhou, Xuedong
    Liu, Bojin
    Wu, Hongkun
    JOURNAL OF ENDODONTICS, 2011, 37 (10) : 1412 - 1416
  • [48] Kinematic Effects of Nickel-Titanium Instruments with Reciprocating or Continuous Rotation Motion: A Systematic Review of In Vitro Studies
    Ahn, So-Yeon
    Kim, Hyeon-Cheol
    Kim, Euiseong
    JOURNAL OF ENDODONTICS, 2016, 42 (07) : 1009 - 1017
  • [49] Effects of Conservative Access and Apical Enlargement on Shaping and Dentin Preservation with Traditional and Modern Instruments: A Micro-computed Tomographic Study
    Aazzouzi-Raiss, Karim
    Ramirez-Mun, Ana
    Mendez, Pedro M.
    Vieira, Gaya C. S.
    Aranguren, Jose
    Perez, Alejandro R.
    JOURNAL OF ENDODONTICS, 2023, 49 (04) : 430 - 437
  • [50] Analysis of second mesiobuccal root canal instrumentation in maxillary first molars with three nickel-titanium rotary instruments: a micro-computed tomographic study
    Zhang, Yuerong
    Liu, Jie
    Gu, Yongchun
    Wang, Juan
    Xu, Hai
    Zhang, Guangdong
    ODONTOLOGY, 2021, 109 (02) : 496 - 505