Effect of Specific Acoustic Resistance of the Matching Layer on the Duration of the Pulse Radiated by a Transducer

被引:0
|
作者
S. I. Konovalov
A. G. Kuzmenko
机构
[1] St. Petersburg Electrotechnical University,
关键词
Small Deviation; Numerical Calculation; Pulse Duration; Material Processing; Particle Velocity;
D O I
暂无
中图分类号
学科分类号
摘要
Based on numerical calculations, changes in the duration of a radiated acoustic pulse due to small deviations in the specific acoustic resistance of the quarter-wave matching layer from the optimum value (from the viewpoint of producing the smallest pulse duration) are studied. We have determined the acceptable range of specific acoustic resistances of the matching layer, in which the duration of a radiated pulse of the particle velocity at the output of a transducer in the form of a piezoelectric plate with a quarter-wave matching layer and different degrees of damping does not increase considerably. These data can be used for rejecting blanks at the early stages of manufacturing transducers.
引用
收藏
页码:97 / 98
页数:1
相关论文
共 43 条
  • [21] The vibro-acoustic analysis of a matching layer attached on a 1–3 piezoelectric composite transducer
    Yi Liu
    Yingqi Sun
    Zhihong Huang
    Yang Wang
    Deping Zeng
    Zengtao Yang
    Journal of Electroceramics, 2022, 48 : 102 - 109
  • [22] Effect of the way of connecting the electric load elements on the pulse duration generated by a piezoelectric transducer
    Konovalov, S. I.
    Kuz'menko, A. G.
    ACOUSTICAL PHYSICS, 2007, 53 (02) : 245 - 247
  • [23] Effect of the way of connecting the electric load elements on the pulse duration generated by a piezoelectric transducer
    S. I. Konovalov
    A. G. Kuz’menko
    Acoustical Physics, 2007, 53 : 245 - 247
  • [24] The vibro-acoustic analysis of a matching layer attached on a 1-3 piezoelectric composite transducer
    Liu, Yi
    Sun, Yingqi
    Huang, Zhihong
    Wang, Yang
    Zeng, Deping
    Yang, Zengtao
    JOURNAL OF ELECTROCERAMICS, 2022, 48 (02) : 102 - 109
  • [25] Effect of matching layer on acoustic lens on suppressing lamb wave formation
    Kubota, J
    Azuma, T
    Ishida, K
    Motoyama, M
    Sato, Y
    Sasaki, K
    Kawabata, K
    Sanghvi, NT
    Umemura, SI
    2003 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2003, : 1044 - 1047
  • [26] Acoustic Matching Layer Films Using B-Stage Thermosetting Polymer Resins for Ultrasound Transducer Applications
    Park, Jae-Hyeong
    Lee, Sang-Mok
    Park, Jongcheol
    Lee, Hyunjoo Jenny
    Paik, Kyung-Wook
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (10) : 2148 - 2154
  • [27] Input pulse duration effect on laser-induced underwater acoustic signals
    Yellaiah, J.
    Kiran, P. Prem
    APPLIED OPTICS, 2021, 60 (16) : 4582 - 4590
  • [28] The effect of asymmetry of acoustic properties of contact layers and a wear plate on the shape of a pulse radiated by a probe into a solid
    S. I. Konovalov
    A. G. Kuz’menko
    Russian Journal of Nondestructive Testing, 2006, 42 : 47 - 50
  • [29] The effect of asymmetry of acoustic properties of contact layers and a wear plate on the shape of a pulse radiated by a probe into a solid
    Konovalov, SI
    Kuz'menko, AG
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2006, 42 (01) : 47 - 50
  • [30] A fiber-shaped ultrasonic transducer by designing a flexible epoxy/nano-zirconia composite as an acoustic matching layer
    Wu, Jiaqi
    Zhang, Yichi
    Liu, Yue
    Zheng, Yuanyuan
    Xu, Kailiang
    Chen, Peining
    Peng, Huisheng