Development and experimental validation of a one-dimensional dynamic hygrothermal modeling based on air humidity ratio

被引:0
|
作者
Xing-guo Guo
You-ming Chen
Yong-qiang Deng
机构
[1] Nanchang University,School of Civil Engineering and Architecture
[2] Hunan University,College of Civil Engineering
来源
关键词
transient hygrothermal modeling; air humidity ratio; modified modeling; experimental test; multilayer wall;
D O I
暂无
中图分类号
学科分类号
摘要
A modified one-dimensional transient hygrothermal model for multilayer wall was proposed using air humidity ratio and temperature as the driving potentials. The solution for the governing equations was obtained numerically by implementing the finite-difference scheme. To evaluate the accuracy of the model, a test system was built up to measure relative humidity and temperature within a porous wall and compare with the prediction of the model. The prediction results have good agreement with the experimental results. For the interface close to indoor side, the maximum deviation of temperature between calculated and test data is 1.87 K, and the average deviation is 0.95 K; the maximum deviation of relative humidity is 11.4%, and the average deviation is 5.7%. For the interface close to outdoor side, the maximum deviation of temperature between prediction and measurement is 1.78 K, and the average deviation is 1.1 K; the maximum deviation of relative humidity is 9.9%, and the average deviation is 4.2%.
引用
收藏
页码:703 / 708
页数:5
相关论文
共 50 条
  • [11] Thin films based one-dimensional photonic crystal for humidity detection
    Peng, Jiankun
    Wang, Weijia
    Qu, Yapeng
    Sun, Tengpeng
    Lv, Dajuan
    Dai, Jixiang
    Yang, Minghong
    SENSORS AND ACTUATORS A-PHYSICAL, 2017, 263 : 209 - 215
  • [12] An experimental and modeling study of barite deposition in one-dimensional tubes
    Jin, Haibo
    Yang, Bei
    Yang, Suohe
    He, Guangxiang
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2015, 125 : 107 - 116
  • [13] DETAILED SINGLE SPRAY EXPERIMENTAL MEASUREMENTS AND ONE-DIMENSIONAL MODELING
    STGEORGES, M
    BUCHLIN, JM
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1994, 20 (06) : 979 - 992
  • [14] One-Dimensional Model of a Compact DHW Heat Pump with Experimental Validation
    Aguilar, F.
    Crespi-Llorens, D.
    Aledo, S.
    Quiles, P. V.
    ENERGIES, 2021, 14 (11)
  • [15] Dynamic Models of Heating and Cooling Coils with One-Dimensional Air Distribution
    G.Krauss
    Journal of Thermal Science, 1993, (02) : 126 - 134
  • [16] One-Dimensional Localization Algorithm Based on Signal Strength Ratio
    Yang, Xinyu
    Kong, Qingru
    Xie, Xiaoyang
    INTERNATIONAL JOURNAL OF DISTRIBUTED SENSOR NETWORKS, 2009, 5 (01): : 79 - 79
  • [17] One-dimensional localization algorithm based on signal strength ratio
    Yang, Xinyu
    Kong, Qingru
    Xie, Xiaoyang
    INTERNATIONAL SYMPOSIUM ON ADVANCES IN COMPUTER AND SENSOR NETWORKS AND SYSTEMS, PROCEEDINGS: IN CELEBRATION OF 60TH BIRTHDAY OF PROF. S. SITHARAMA IYENGAR FOR HIS CONTRIBUTIONS TO THE SCIENCE OF COMPUTING, 2008, : 488 - 494
  • [18] A hygrothermal stress finite element analysis of laminated beam structures through hierarchical one-dimensional modeling
    Hui, Y.
    Giunta, G.
    De Pietro, G.
    Belouettar, S.
    Carrera, E.
    Yang, J.
    Hu, H.
    MECHANICS OF ADVANCED MATERIALS AND STRUCTURES, 2022, 29 (21) : 3040 - 3054
  • [19] Linearly resistive humidity sensor based on quasi one-dimensional ZnSe nanostructures
    Leung, Y. P.
    Choy, Wallace C. H.
    Yuk, T. I.
    CHEMICAL PHYSICS LETTERS, 2008, 457 (1-3) : 198 - 201
  • [20] One-Dimensional Modeling of the Pressure Loss in Concrete Pumping and Experimental Verification
    Zhao, Xuan
    Gao, Guoqiang
    Wan, Minshun
    Dai, Juchuan
    APPLIED SCIENCES-BASEL, 2024, 14 (07):