Main anatomical features of the M1 segment of the middle cerebral artery: a 3D time-of-flight magnetic resonance angiography at 3 T study

被引:0
|
作者
Fabrice Vuillier
Elisabeth Medeiros
Thierry Moulin
Francoise Cattin
Jean-Francois Bonneville
Laurent Tatu
机构
[1] Centre Hospitalier Universitaire Jean Minjoz,Service de Neurologie
[2] CHU Besancon,Département d’Anatomie, Faculté de Médecine
[3] Centre Hospitalier Universitaire Jean Minjoz,Service de Neuroradiologie
来源
关键词
Middle cerebral artery; M1 segment; Anatomy; Magnetic resonance angiography; Stroke;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of our study was to determine the main anatomical features of the M1 segment of middle cerebral artery (MRA) using a 3D TOF-MRA at 3 T. Reconstructed and post-processed MRA images were independently analysed by two anatomists in order to determine the course patterns, the division patterns and the early cortical branches patterns of the M1 segments. The division patterns were defined as bipode, tripode or other. The ECB were studied according to their number and their distance from the origin of the M1 segment. The interobserver agreement, to determine the division patterns of the M1 segment, was calculated. The division of the M1 segment was bipode in 73% of the MCAs, monopode in 17%, tripode in 9%, and fan-shaped in 1. In 46% of the cases no ECB was found. In the other cases, only 1 ECB was found and it arose from the medium part of the M1 segment. Our results confirm post-mortem microdissection studies and show that strict anatomical criteria may be applied to 3D TOF MRA at 3 T.
引用
收藏
页码:509 / 514
页数:5
相关论文
共 50 条
  • [21] Clinical and experimental investigation of pseudoaneurysm in the anterior communicating artery area on 3-dimensional time-of-flight cerebral magnetic resonance angiography
    Chung, TS
    Lee, YJ
    Kang, WS
    Kang, SK
    Rhim, YC
    Yoo, BG
    Park, IK
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (03) : 414 - 421
  • [22] Diagnostic value of 3D time-of-flight magnetic resonance angiography for detecting intracranial aneurysm: a meta-analysis
    Liu HaiFeng
    Xu YongSheng
    Xun YangQin
    Dou Yu
    Wang ShuaiWen
    Lu XingRu
    Lei JunQiang
    Neuroradiology, 2017, 59 : 1083 - 1092
  • [23] Phase contrast and time-of-flight magnetic resonance angiography of the intracerebral arteries at 1.5, 3 and 7 T
    Stamm, Anna C.
    Wright, Chadwick L.
    Knopp, Michael V.
    Schmalbrock, Petra
    Heverhagen, Johannes T.
    MAGNETIC RESONANCE IMAGING, 2013, 31 (04) : 545 - 549
  • [24] Signal Intensity Changes for the Middle Cerebral Artery on 3-Dimensional Time-of-flight Magnetic Resonance Angiography Indicate Acute Hemodynamic Changes after Carotid Endarterectomy
    Sato, Kimitoshi
    Kurata, Akira
    Oka, Hidehiro
    Kan, Shinichi
    Inoue, Yusuke
    Asano, Yuji
    Fujii, Kiyotaka
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2013, 22 (08): : E511 - E515
  • [25] Prospective optical motion correction for 3D time-of-flight angiography
    Kopeinigg, Daniel
    Aksoy, Murat
    Forman, Christoph
    Straka, Matus
    Seaman, Danielle
    Rosenberg, Jarrett
    Fleischmann, Dominik
    Hornegger, Joachim
    Bammer, Roland
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (06) : 1623 - 1633
  • [26] Compressed Sensing 3-Dimensional Time-of-Flight Magnetic Resonance Angiography for Cerebral Aneurysms Optimization and Evaluation
    Fushimi, Yasutaka
    Fujimoto, Koji
    Okada, Tomohisa
    Yamamoto, Akira
    Tanaka, Toshiyuki
    Kikuchi, Takayuki
    Miyamoto, Susumu
    Togashi, Kaori
    INVESTIGATIVE RADIOLOGY, 2016, 51 (04) : 228 - 235
  • [27] Malignant glioma - Evaluation with 3D time-of-flight MR angiography
    Kadota, T
    Nakagawa, H
    Kuroda, C
    ACTA RADIOLOGICA, 1998, 39 (03) : 227 - 232
  • [28] A laminar flow model for 3D Time-of-Flight MR Angiography
    Chen, DJ
    Hedges, LK
    Yu, CX
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2167 - 2170
  • [29] COMPARISON OF 3-DIMENSIONAL PHASE-CONTRAST MAGNETIC-RESONANCE ANGIOGRAPHY WITH 3-DIMENSIONAL TIME-OF-FLIGHT MAGNETIC-RESONANCE ANGIOGRAPHY IN CEREBRAL ANEURYSMS
    IKAWA, F
    SUMIDA, M
    UOZUMI, T
    KUWABARA, S
    KIYA, K
    KURISU, K
    ARITA, K
    SATOH, H
    SURGICAL NEUROLOGY, 1994, 42 (04): : 287 - 292
  • [30] The three-dimensional shape analysis of the M1 segment of the middle cerebral artery using MRA at 3T
    Han, Jintao
    Qiao, Huiting
    Li, Xuan
    Li, Xiaogang
    He, Qingyuan
    Wang, Yu
    Cheng, Ziman
    NEURORADIOLOGY, 2014, 56 (11) : 995 - 1005