Femoral cementing techniques in total hip replacement

被引:0
|
作者
J. Rice
T. Prenderville
P. Murray
B. McCormack
W. Quinlan
机构
[1] Cappagh Orthopaedic Hospital,
[2] Finglas,undefined
[3] Dublin 11,undefined
[4] Ireland,undefined
[5] The Bioengineering Centre,undefined
[6] Department of Mechanical Engineering,undefined
[7] University College Dublin,undefined
[8] Belfield,undefined
[9] Dublin,undefined
来源
关键词
Computerise Image; Equivalent Diameter; Femoral Stem; Cement Mantle; Computerise Image Analysis;
D O I
暂无
中图分类号
学科分类号
摘要
Clinical studies have shown that second-generation femoral cementing techniques at total hip replacement result in a superior fixation of the femoral stem. In an effort to determine what benefits further developments in cementing techniques would provide, we compared the morphology of the cement mantles produced by traditional finger-packing and gun-insertion techniques. The porosity of the cement mantles was quantified using computerised image analysis. The finger-packing technique caused large air inclusions that resulted in large pores in the substance of the cement mantle, whereas the cement-gun technique did not result in any individual pore with an equivalent diameter greater than 3 mm. The mean porosity of cement mantles prepared using the finger-insertion technique was 8.3%, whereas the mean porosity in gun-prepared mantles was 1.7%. The use of a cement gun significantly reduced the porosity of femoral cement mantles (P=0.02). Reduction of defects in the substance of the cement mantle may account for the increased survival of femoral prostheses inserted when second-generation techniques were used. Further reduction of the porosity of the cement mantle could not be expected to produce as dramatic a clinical improvement in prosthesis fixation.
引用
收藏
页码:308 / 311
页数:3
相关论文
共 50 条
  • [41] Common femoral artery injury following total hip replacement
    Manzano Grossi, Maria Soledad
    Ayala Strub, Maria Azucena
    de Francisco Torres, Tamara
    Garcia Pajares, Rosario
    Ligero Ramos, Jose Manuel
    ANGIOLOGIA, 2019, 71 (04): : 164 - 166
  • [42] FEMORAL VEIN-THROMBOSIS AND TOTAL HIP-REPLACEMENT
    CLARKE, AK
    BRITISH MEDICAL JOURNAL, 1977, 2 (6101): : 1542 - 1542
  • [43] TOTAL HIP-REPLACEMENT FOLLOWING FAILED FEMORAL HEMIARTHROPLASTY
    AMSTUTZ, HC
    SMITH, RK
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1979, 61 (08): : 1161 - 1166
  • [44] Salvage of Failed Total Hip Arthroplasty With Proximal Femoral Replacement
    Savvidou, Olga D.
    Mavrogenis, Andreas F.
    Sakellariou, Vasilios
    Christogiannis, Ioannis
    Vottis, Christos
    Christodoulou, Michael
    Vlasis, Konstantinos
    Papagelopoulos, Panayiotis J.
    ORTHOPEDICS, 2014, 37 (10) : 691 - 698
  • [45] Transient subluxation of the femoral head after total hip replacement
    McGrory, B. J.
    McGrory, C. P.
    Barbour, L.
    Barbour, B.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (11): : 1522 - 1526
  • [46] FRACTURE OF THE FEMORAL PROSTHESIS AFTER TOTAL HIP-REPLACEMENT
    MCNEUR, JC
    MEDICAL JOURNAL OF AUSTRALIA, 1984, 141 (06) : 341 - 344
  • [47] Variation in femoral anteversion in patients requiring total hip replacement
    Pierrepont, Jim W.
    Marel, Ed
    Bare, Jonathan, V
    Walter, Leonard R.
    Stambouzou, Catherine Z.
    Solomon, Michael, I
    McMahon, Stephen
    Shimmin, Andrew J.
    HIP INTERNATIONAL, 2020, 30 (03) : 281 - 287
  • [48] Is the length of the femoral component important in primary total hip replacement?
    Feyen, H.
    Shimmin, A. J.
    BONE & JOINT JOURNAL, 2014, 96B (04): : 442 - 448
  • [49] THE SURVIVAL OF THE CEMENTED FEMORAL COMPONENT OF A TOTAL HIP-REPLACEMENT
    RITTER, MA
    CAMPBELL, ED
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1989, (243) : 143 - 147
  • [50] Improvement of the safety of ceramic femoral heads for total hip replacement
    Willmann, G
    Pfaff, HG
    Richter, HG
    BIOMEDIZINISCHE TECHNIK, 1995, 40 (12): : 342 - 346