Using inertial measurement units to estimate spine joint kinematics and kinetics during walking and running

被引:0
|
作者
Benjamin E. Sibson
Jacob J. Banks
Ali Yawar
Andrew K. Yegian
Dennis E. Anderson
Daniel E. Lieberman
机构
[1] Harvard University,Department of Human Evolutionary Biology
[2] Beth Israel Deaconess Medical Center,Center for Advanced Orthopedic Studies
[3] Harvard Medical School,Department of Orthopedic Surgery
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Optical motion capture (OMC) is considered the best available method for measuring spine kinematics, yet inertial measurement units (IMU) have the potential to collect data outside the laboratory. When combined with musculoskeletal modeling, IMU technology may be used to estimate spinal loads in real-world settings. To date, IMUs have not been validated for estimates of spinal movement and loading during both walking and running. Using OpenSim Thoracolumbar Spine and Ribcage models, we compare IMU and OMC estimates of lumbosacral (L5/S1) and thoracolumbar (T12/L1) joint angles, moments, and reaction forces during gait across six speeds for five participants. For comparisons, time series are ensemble averaged over strides. Comparisons between IMU and OMC ensemble averages have low normalized root mean squared errors (< 0.3 for 81% of comparisons) and high, positive cross-correlations (> 0.5 for 91% of comparisons), suggesting signals are similar in magnitude and trend. As expected, joint moments and reaction forces are higher during running than walking for IMU and OMC. Relative to OMC, IMU overestimates joint moments and underestimates joint reaction forces by 20.9% and 15.7%, respectively. The results suggest using a combination of IMU technology and musculoskeletal modeling is a valid means for estimating spinal movement and loading.
引用
收藏
相关论文
共 50 条
  • [41] Low back three-dimensional joint forces, kinematics, and kinetics during walking
    Callaghan, JP
    Patla, AE
    McGill, SM
    [J]. CLINICAL BIOMECHANICS, 1999, 14 (03) : 203 - 216
  • [42] Head Impact Kinematics Estimation With Network of Inertial Measurement Units
    Kuo, Calvin
    Sganga, Jake
    Fenton, Michael
    Camarillo, David B.
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2018, 140 (09):
  • [43] Real-time Estimate of Body Kinematics During a Planar Squat Task Using a Single Inertial Measurement Unit
    Bonnet, Vincent
    Mazza, Claudia
    Fraisse, Philippe
    Cappozzo, Aurelio
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (07) : 1920 - 1926
  • [44] Joint kinematics and kinetics of overground accelerated running versus running on an accelerated treadmill
    Van Caekenberghe, Ine
    Segers, Veerle
    Aerts, Peter
    Willems, Patrick
    De Clercq, Dirk
    [J]. JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2013, 10 (84)
  • [45] Spine stabilization by psoas muscle during walking and running
    Penning, L
    [J]. EUROPEAN SPINE JOURNAL, 2002, 11 (01) : 89 - 90
  • [46] Spine stabilization by psoas muscle during walking and running
    L. Penning
    [J]. European Spine Journal, 2002, 11 : 89 - 90
  • [47] Estimation of horizontal running power using foot-worn inertial measurement units
    Apte, Salil
    Falbriard, Mathieu
    Meyer, Frederic
    Millet, Gregoire P.
    Gremeaux, Vincent
    Aminian, Kamiar
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [48] Walking in a controlled ankle motion (CAM) boot: In-boot measurement of joint kinematics and kinetics
    Stolycia, Mason L.
    Lunn, David E.
    Wilkins, Richard A.
    Barnett, Cleveland T.
    Walker, Josh
    [J]. JOURNAL OF BIOMECHANICS, 2024, 176
  • [49] Predicting Tissue Loads in Running from Inertial Measurement Units
    Rasmussen, John
    Skejo, Sebastian
    Waagepetersen, Rasmus Plenge
    [J]. SENSORS, 2023, 23 (24)
  • [50] Measuring joint kinematics of treadmill walking and running: Comparison between an inertial sensor based system and a camera-based system
    Nuesch, Corina
    Roos, Elena
    Pagenstert, Geert
    Mundermann, Annegret
    [J]. JOURNAL OF BIOMECHANICS, 2017, 57 : 32 - 38