ANFIS-Based Accurate Estimation of the Confinement Effect for Concrete-Filled Steel Tubular (CFST)

被引:0
|
作者
S. Balasubramanian
J. Jegan
M. C. Sundarraja
机构
[1] Mohamed Sathak Engineering College,Faculty of Civil Engineering
[2] University College of Engineering & Technology,Faculty of Civil Engineering
[3] Thiagarajar College of Engineering,undefined
来源
关键词
Concrete-filled; ANFIS; CFST column; Short and long; ratio; ANN; Load capacity; OTR; SD; MV;
D O I
暂无
中图分类号
学科分类号
摘要
This research is mainly focused on the accurate estimation of the confinement effect for the concrete-filled steel tubular (CFST) that makes it possible to evaluate the interaction between various parameters that affect the confinement effect. To do that, the CFST is analyzed with concrete and steel properties using ANFIS method. With respect to the shape of the CFST, both the circular and rectangle shapes are considered. Only then, the D/t ratio is increased and reduced the hoop stress, self-stress in the steel tube. To analyze the D/t ratio, the confinement effect and axial load capacity is determined. After that, the concrete strength is also analyzed according to their statistical measures like output target ratio (OTR), precision, efficiency, mean value (MV), mean square error (MSE), standard deviation (SD), etc. The proposed method is implemented in MATLAB platform and compared with the Artificial Neural Network (ANN) method. The proposed ANFIS method achieved a good prediction of the confinement effect and axial load capacity of the CFST.
引用
收藏
页码:1760 / 1771
页数:11
相关论文
共 50 条
  • [21] Burnout resistance of concrete-filled steel tubular (CFST) columns under realistic fire conditions
    Szymkuc, Wojciech
    Malendowski, Michal
    Glema, Adam
    ce/papers, 2023, 6 (3-4) : 2184 - 2188
  • [22] Detection of subsurface voids in concrete-filled steel tubular (CFST) structure using percussion approach
    Chen, Dongdong
    Montano, Victor
    Huo, Linsheng
    Fan, Shuli
    Song, Gangbing
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 262 (262)
  • [23] Fire resistance of circular concrete-filled steel tubular (CFST) column protected by intumescent coating
    Song, Qian-Yi
    Han, Lin-Hai
    Zhou, Kan
    Feng, Yuan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 147 : 154 - 170
  • [24] Size effect of axial-loaded concrete-filled steel tubular columns with different confinement coefficients
    Jin, Liu
    Fan, Lingling
    Li, Ping
    Du, Xiuli
    ENGINEERING STRUCTURES, 2019, 198
  • [25] Effect of Concrete Confinement On Axial Strength Of Circular Concrete-filled Steel Tubes
    Umamaheswari, N.
    Jayachandran, S. Arul
    Lakshmipathy, M.
    STEEL CONCRETE COMPOSITE AND HYBRID STRUCTURES, 2009, : 271 - 278
  • [26] Confinement-based design and behaviour of concrete-filled stiffened steel tubular square slender columns
    Hassanein, M. F.
    Huang, Wei-Feng
    Shao, Yong-Bo
    Cashell, K. A.
    Elsisy, A. R.
    OCEAN ENGINEERING, 2024, 304
  • [27] Recycled concrete-filled steel tubular columns
    Yang, You-Fu
    Han, Lin-Hai
    Advances in Structural Engineering:Theory and Applications Vols 1 and 2, 2006, : 1508 - 1515
  • [28] Confinement effectiveness of circular concrete-filled steel tubular columns under axial compression
    Wei, Yang
    Jiang, Cheng
    Wu, Yu-Fei
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 158 : 15 - 27
  • [29] Behavior of prestressed concrete-filled steel tube (CFST) beam
    Zhan, Yulin
    Zhao, Renda
    Ma, Zhongguo John
    Xu, Tengfei
    Song, Ruinian
    ENGINEERING STRUCTURES, 2016, 122 : 144 - 155
  • [30] Post-blast capacity evaluation of concrete-filled steel tubular (CFST) column based on machine learning technique
    Li, Jie
    Pang, Yanfen
    Mu, Quanping
    Zhang, Xuejie
    Shi, Yanchao
    Wang, Honglong
    ADVANCES IN STRUCTURAL ENGINEERING, 2023, 26 (11) : 1953 - 1972