Long-term results of tissue-engineered small-caliber vascular grafts in a rat carotid arterial replacement model

被引:0
|
作者
Fumiaki Kuwabara
Yuji Narita
Aika Yamawaki-Ogata
Makoto Satake
Hiroaki Kaneko
Hideki Oshima
Akihiko Usui
Yuichi Ueda
机构
[1] Gifu Prefectural Tajimi Hospital,Department of Cardiovascular Surgery
[2] Nagoya University Graduate School of Medicine,Department of Cardiac Surgery
[3] Teijin Limited,Technology Innovation Center
来源
关键词
Tissue engineering; Small-caliber vascular graft; Long-term result;
D O I
暂无
中图分类号
学科分类号
摘要
The concept of tissue engineered small-caliber vascular grafts (TE-SCVGs) is theoretically ideal. In this study, we evaluated the long-term (more than 1 year) course of TE-SCVGs using a rat carotid arterial replacement model. We fabricated a TE-SCVG scaffold (0.7 mm in diameter) with electrospun nano-scale fibers. Poly-ε-caprolactone was used as a biodegradable polymer. These artificial vessels were then used in carotid arterial replacement performed on Sprague–Dawley rats. The implanted grafts were removed at an early phase (1, 2, 6 weeks), middle phase (12, 24 weeks), and late phase (48, 72 weeks) after implantation. Twenty-nine patent grafts from among the 40 implanted grafts (patency 72.5 %) could be evaluated. No aneurysm formation was observed during the follow-up period. Endothelial cells positive for immunostaining with von Willebrand factor were found to be already attached to the inner surface of the TE-SCVGs in the early phase. The percentage of smooth muscle cell specific marker (α-smooth muscle actin and calponin with fluorescent immunostaining) positive cells, which seemed to be mesenchymal cells in the graft wall, increased with time, while, in contrast, the scaffold material decreased. Even after 72 weeks, however, although the scaffold material had degraded, it had not disappeared completely. These results show that the novel TE-SCVGs we developed were still functioning in the rat carotid arterial circulation after more than 1 year. However, further investigations will be required with regard to regeneration of the SMC layer and the complete degradation of graft materials.
引用
收藏
页码:399 / 405
页数:6
相关论文
共 50 条
  • [31] Tissue-Engineered Submillimeter Diameter Vascular Grafts for Free Flap Survival in Rat Model
    Yamanaka, H.
    Mahara, A.
    Suzuki, S.
    Yamaoka, T.
    TISSUE ENGINEERING PART A, 2017, 23 : S124 - S125
  • [32] Characterization of small-diameter electrospun tissue-engineered arterial grafts
    Mirensky, Tamar L.
    Fein, Corey W.
    Nguyen, Gerard K.
    Hibino, Narutoshi
    Sawh-Martinez, Rajendra F.
    Yi, Tai
    McGillicuddy, Edward A.
    Villalona, Gustavo
    Shinoka, Toshiharu
    Breuer, Christopher K.
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2009, 209 (03) : S30 - S30
  • [33] Evaluation of compliance and stiffness of decellularized tissues as scaffolds for tissue-engineered small caliber vascular grafts using intravascular ultrasound
    Murase, Yosuke
    Narita, Yuji
    Kagami, Hideaki
    Miyamoto, Keiichi
    Ueda, Yuichi
    Ueda, Minoru
    Murohara, Toyoaki
    ASAIO JOURNAL, 2006, 52 (04) : 450 - 455
  • [34] BIOACTIVE COATING FOR TISSUE-ENGINEERED SMALL-DIAMETER VASCULAR GRAFTS
    Surguchenko, V. A.
    Nemets, E. A.
    Belov, V. Yu
    Sevastianov, V., I
    VESTNIK TRANSPLANTOLOGII I ISKUSSTVENNYH ORGANOV, 2021, 23 (04): : 119 - 131
  • [35] Circulating endothelial cells for tissue-engineered small diameter vascular grafts
    Kaushal, S
    Amiel, G
    Guleserian, KJ
    Tjorvi, PE
    Soker, S
    Roth, SJ
    Atala, A
    Bischoff, J
    Mayer, JE
    CIRCULATION, 2000, 102 (18) : 766 - 766
  • [36] LONG-TERM RESULTS OF ARTERIAL GRAFTS
    DUBOST, C
    DALLAINE.C
    ALFANDARI, JP
    JOURNAL OF CARDIOVASCULAR SURGERY, 1964, 5 (06): : 521 - +
  • [37] Long-term results of autologous scaffold-free tissue-engineered vascular graft for hemodialysis access
    Wystrychowski, Wojciech
    Garrido, Sergio A.
    Marini, Alicia
    Dusserre, Nathalie
    Radochonski, Sam
    Zagalski, Krzysztof
    Antonelli, Jorge
    Canalis, Manuel
    Sammartino, Andrea
    Darocha, Zbigniew
    Baczynski, Ryszard
    Cierniak, Tomasz
    Regele, Heinz
    de la Fuente, Luis M.
    Cierpka, Lech
    McAllister, Todd N.
    L'Heureux, Nicolas
    JOURNAL OF VASCULAR ACCESS, 2024, 25 (01): : 254 - 264
  • [38] ARTERIAL-WALL REGENERATION IN SMALL-CALIBER VASCULAR GRAFTS IN RATS - NEOENDOTHELIAL HEALING AND PROSTACYCLIN PRODUCTION
    VANDERLEI, B
    DARIUS, H
    SCHROR, K
    NIEUWENHUIS, P
    MOLENAAR, I
    WILDEVUUR, CRH
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1985, 90 (03): : 378 - 386
  • [39] LONG-TERM RESULTS OF VASCULAR GRAFTS
    OECONOMOS, N
    JOURNAL OF CARDIOVASCULAR SURGERY, 1964, 5 (06): : 576 - +
  • [40] Tissue-engineered submillimeter-diameter vascular grafts for free flap survival in rat model
    Yamanaka, Hiroki
    Yamaoka, Tetsuji
    Mahara, Atsushi
    Morimoto, Naoki
    Suzuki, Shigehiko
    BIOMATERIALS, 2018, 179 : 156 - 163