Treatment of displaced transverse fractures of the patella: modified tension band wiring technique with or without augmented circumferential cerclage wire fixation

被引:0
|
作者
Tien-Yu Yang
Tsan-Wen Huang
Po-Yao Chuang
Kuo-Chin Huang
机构
[1] Chang Gung University College of Medicine,Department of Orthopaedic Surgery
[2] Chang Gung Memorial Hospital,undefined
关键词
Patella fracture; Tension band wiring; Circumferential cerclage wiring; Fixation failure; Nonunion;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [21] An original internal fixation technique by tension band wiring with steel wire in fractures of the coronoid process
    Mallard, F.
    Hubert, L.
    Steiger, V.
    Cronier, P.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (04) : S211 - S215
  • [22] Fixation of Comminuted Patellar Fracture with Combined Cerclage and Tension Band Wiring Technique
    Ong, T. K.
    Chee, E. K.
    Wong, C. L.
    Thevarajan, K.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2008, 2 (02) : 40 - 42
  • [23] Cannulated Screw and Cable are Superior to Modified Tension Band in the Treatment of Transverse Patella Fractures
    Tian, Yun
    Zhou, Fang
    Ji, Hongquan
    Zhang, Zhishan
    Guo, Yan
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (12) : 3429 - 3435
  • [24] Tension-band wiring of closed transverse fractures of patella; effect of site of wire twists and orientation of stainless steel wire loop
    Afsar, Sardar Sohail
    Gulzar, Mohammad
    Idrees, Mohammad
    Babar, Iqtidar Uilah
    RAWAL MEDICAL JOURNAL, 2014, 39 (03): : 292 - 296
  • [25] Horizontal Versus Vertical Orientation of the Loop for Tension Band Wiring of Transverse Patella Fractures
    Lee, Sang Ki
    Hwang, Yoon Sub
    Choy, Won Sik
    ORTHOPEDICS, 2014, 37 (03) : E265 - E271
  • [26] Open Reduction and Internal Fixation of Displaced Patella Inferior Pole Fractures With Anterior Tension Band Wiring Through Cannulated Screws
    Chang, Shi-Min
    Ji, Xiang-Ling
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (06) : 366 - 370
  • [27] TECHNIQUE AND RESULTS OF LATERAL TENSION BAND WIRING OF PATELLA AND OLECRANON-FRACTURES
    LABITZKE, R
    TOWFIGH, H
    UNFALLHEILKUNDE-TRAUMATOLOGY, 1980, 83 (09): : 450 - 456
  • [28] Internal fixation of displaced inferior pole of the patella fractures using vertical wiring augmented with Krachow suturing
    Oh, Hyoung-Keun
    Choo, Suk-Kyu
    Kim, Ji-Wan
    Lee, Mark
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (12): : 2512 - 2515
  • [29] Cerclage fixation without K-wires is associated with fewer complications and reoperations compared with tension band wiring in stable displaced olecranon fractures in elderly patients
    Wenger, Daniel
    Cornefjord, Gustav
    Rogmark, Cecilia
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (10) : 2669 - 2676
  • [30] Cerclage fixation without K-wires is associated with fewer complications and reoperations compared with tension band wiring in stable displaced olecranon fractures in elderly patients
    Daniel Wenger
    Gustav Cornefjord
    Cecilia Rogmark
    Archives of Orthopaedic and Trauma Surgery, 2022, 142 : 2669 - 2676