3D characterization of bone strains in the rat tibia loading model

被引:0
|
作者
Antonia Torcasio
Xiaolei Zhang
Joke Duyck
G. Harry van Lenthe
机构
[1] K.U.Leuven,Division of Biomechanics and Engineering Design, Department of Mechanical Engineering
[2] K.U.Leuven,BIOMAT, Department of Prosthetic Dentistry
[3] ETH Zurich,Institute for Biomechanics
关键词
Tissue-level strains; Micro-CT; Voxel-based finite element models; Rat tibia compression loading; Strain gauge measurements;
D O I
暂无
中图分类号
学科分类号
摘要
Bone strain is considered one of the factors inducing bone tissue response to loading. Nevertheless, where animal studies can provide detailed data on bone response, they only offer limited information on experimental bone strains. Including micro-CT-based finite element (micro FE) models in the analysis represents a potent methodology for quantifying strains in bone. Therefore, the main objective of this study was to develop and validate specimen-specific micro FE models for the assessment of bone strains in the rat tibia compression model. Eight rat limbs were subjected to axial compression loading; strain at the medio-proximal site of the tibiae was measured by means of strain gauges. Specimen-specific micro FE models were created and analyzed. Repeated measurements on each limb indicated that the effect of limb positioning was small (COV = 6.45 ± 2.27 %). Instead, the difference in the measured strains between the animals was high (54.2%). The computational strains calculated at the strain gauge site highly correlated to the measured strains (R2 = 0.95). Maximum peak strains calculated at exactly 25% of the tibia length for all specimens were equal to 435.11 ± 77.88 microstrains (COV = 17.19%). In conclusion, we showed that strain gauge measurements are very sensitive to the exact strain gauge location on the bone; hence, the use of strain gauge data only is not recommended for studies that address at identifying reliable relationships between tissue response and local strains. Instead, specimen-specific micro FE models of rat tibiae provide accurate estimates of tissue-level strains.
引用
收藏
页码:403 / 410
页数:7
相关论文
共 50 条
  • [41] Characterizing gait induced normal strains in a murine tibia cortical bone defect model
    Prasad, Jitendra
    Wiater, Brett P.
    Nork, Sean E.
    Bain, Steven D.
    Gross, Ted S.
    JOURNAL OF BIOMECHANICS, 2010, 43 (14) : 2765 - 2770
  • [42] Development of a 3D bone marrow adipose tissue model
    Fairfield, Heather
    Falank, Carolyne
    Farrell, Mariah
    Vary, Calvin
    Boucher, Joshua M.
    Driscoll, Heather
    Liaw, Lucy
    Rosen, Clifford J.
    Reagan, Michaela R.
    BONE, 2019, 118 : 77 - 88
  • [43] A 3D statistical shape model of the pelvic bone for segmentation
    Lamecker, H
    Seebass, M
    Hege, HC
    Deuflhard, P
    MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 : 1341 - 1351
  • [44] Orthopaedic Surgical Robot Manipulator 3D model of a bone
    Sindhu, V.
    Santhanakrishnan, Soundarapandian
    PROCEEDINGS OF 2016 INTERNATIONAL CONFERENCE ON ROBOTICS: CURRENT TRENDS AND FUTURE CHALLENGES (RCTFC): ROBOTICS FOR HUMAN DEVELOPMENT, 2016,
  • [45] 3D in vitro model of breast cancer colonization of bone
    Krishnan, Venkatesh
    Vogler, Erwin
    Mastro, Andrea
    CANCER RESEARCH, 2009, 69
  • [46] Development of an 3D ex vivo model of bone tissue
    Gamblin, A. L.
    Renaud, A.
    Amimaud, J.
    Hulin, P.
    Trichet, V.
    Heymann, D.
    Layrolle, P.
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2012, 6 : 350 - 350
  • [47] 3D ACTIVE BONE FORMING MODEL TO STUDY AMELOBLASTOMA
    Bakkalci, Deniz
    TISSUE ENGINEERING PART A, 2022, 28 : S44 - S44
  • [48] 3D characterization of localized shear failure in loess subject to triaxial loading
    Zhou, Y. Y.
    Yu, B.
    Fan, W.
    Dijkstra, T. A.
    Wei, Y. N.
    Deng, L. S.
    ENGINEERING GEOLOGY, 2023, 322
  • [49] Combined registration of 3D tibia and femur implant models in 3D magnetic resonance images
    Jovanovic, A
    Siebert, M
    Von Eisenhart-Rothe, R
    Graichen, H
    Englmeier, KH
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1244 - 1244
  • [50] Using digital image correlation to determine bone surface strains during loading and after adaptation of the mouse tibia
    Sztefek, Pavel
    Vanleene, Maximilien
    Olsson, Robin
    Collinson, Rebecca
    Pitsillides, Andrew A.
    Shefelbine, Sandra
    JOURNAL OF BIOMECHANICS, 2010, 43 (04) : 599 - 605