Six-stage cascade paramagnetic mode magnetophoretic separation system for human blood samples

被引:0
|
作者
Youngdo Jung
Yoonsu Choi
Ki-Ho Han
A. Bruno Frazier
机构
[1] School of Electrical and Computer Engineering,School of Nano Engineering
[2] Georgia Institute of Technology,undefined
[3] Inje University,undefined
来源
Biomedical Microdevices | 2010年 / 12卷
关键词
Human whole blood; Cell separator; High Gradient Magnetic Field Separation (HGMS); Magnetophoresis; Microfluidic system;
D O I
暂无
中图分类号
学科分类号
摘要
This paper is focused on the development of a six-stage cascade paramagnetic mode magnetophoretic separation (PMMS) system for separating suspended cells in blood based on their native magnetic properties. The design and fabrication of a PMMS system are presented and the microfluidic separation system is characterized experimentally using human whole blood as the case study. The PMMS system can separate blood cells types continuously using the magnetophoretic force produced from a high magnetic field gradient without magnetic or fluorescent tagging. Experimental results demonstrated that red blood cell separation in the PMMS system at a volumetric flow rate of 28.8 μL / hr, resulting in a separation time of 10.4 min for a 5.0 μL blood sample with a separation efficiency of 89.5 ± 0.20%. The PMMS system was tested at higher volumetric flow rates of 50.4 μL / hr and 72.0 μL / hr. The measured separation efficiencies were 86.2 ± 1.60% and 59.9 ± 6.06% respectively.
引用
收藏
页码:637 / 645
页数:8
相关论文
共 49 条
  • [1] Six-stage cascade paramagnetic mode magnetophoretic separation system for human blood samples
    Jung, Youngdo
    Choi, Yoonsu
    Han, Ki-Ho
    Frazier, A. Bruno
    BIOMEDICAL MICRODEVICES, 2010, 12 (04) : 637 - 645
  • [2] 6-stage cascade mode magnetophoretic microseparator for human blood cells
    Jung, Youngdo
    Choi, Yoonsu
    Han, Ki-Ho
    Frazier, A. Bruno
    TRANSDUCERS '07 & EUROSENSORS XXI, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2007,
  • [3] Paramagnetic capture mode magnetophoretic microseparator for blood cells
    Han, K. -H.
    Frazier, A. B.
    IEE PROCEEDINGS-NANOBIOTECHNOLOGY, 2006, 153 (04): : 67 - 73
  • [4] 300 GHz Six-Stage Differential-Mode Amplifier
    Park, H. J.
    Rieh, J. S.
    Kim, M.
    Hacker, J. B.
    2010 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST (MTT), 2010, : 49 - 52
  • [5] Cascade mode magnetophoretic microseparator for high efficiency blood cell separations
    Han, KH
    Frazier, AB
    Transducers '05, Digest of Technical Papers, Vols 1 and 2, 2005, : 1680 - 1683
  • [6] Paramagnetic capture mode magnetophoretic microseparator for high efficiency blood cell separations
    Han, KH
    Frazier, AB
    LAB ON A CHIP, 2006, 6 (02) : 265 - 273
  • [7] Hexa-tert-butyltribenzodecacyclenyl: A six-stage amphoteric redox system
    Kubo, T
    Yamamoto, K
    Nakasuji, K
    Takui, T
    Murata, I
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION IN ENGLISH, 1996, 35 (04): : 439 - 441
  • [8] Capillary magnetophoresis of human blood cells and their magnetophoretic trapping in a flow system
    Watarai, H
    Namba, M
    JOURNAL OF CHROMATOGRAPHY A, 2002, 961 (01) : 3 - 8
  • [9] The Integration of Work and Study in Classroom Teaching in Higher Vocational Education Action-Oriented Six-Stage Teaching Mode
    Zhang, Hongshi
    Tan, Jing
    PROCEEDINGS OF 2012 7TH INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE & EDUCATION, VOLS I-VI, 2012, : 1460 - 1463
  • [10] 4,7,11,14,18,21-Hexa-t-butyltribenzodecacyclenyl radical:: A six-stage amphoteric redox system
    Kubo, T
    Yamamoto, K
    Nakasuji, K
    Takui, T
    Murata, I
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 2001, 74 (11) : 1999 - 2009