Optimization of DG Units in Distribution Systems for Voltage Sag Minimization Considering Various Load Types

被引:0
|
作者
Hamid HassanzadehFard
Alireza Jalilian
机构
[1] Iran University of Science and Technology,School of Electrical Engineering
[2] Iran University of Science and Technology,Center of Excellence for Power Systems Automation and Operation, School of Electrical Engineering
关键词
Distribution system; Particle swarm optimization; Power quality; Voltage sag;
D O I
暂无
中图分类号
学科分类号
摘要
The optimum installation of distributed generation (DG) units in distribution systems has always been challenging due to the continually increase of electrical energy demands. However, the improper installation of DG units may have negative impact on the power quality of the distribution system. Voltage sag is one of the most important power quality problems, which has the bad effects on the performances of different loads, especially on sensitive and uninterruptible loads. To mitigate the voltage sag problem in distribution systems, a new formulation is proposed for optimal location and sizing of DG units. Particle swarm optimization algorithm is employed to solve the problem. The minimization of the total power losses, total cost of DG units, improvement of the voltage profile, and the reduction in the voltage sag effect are considered as the main objectives. To involve the voltage sag occurrence in distribution system, a penalty is considered for interruption of each type of available load. Different types of load models such as industrial, residential and commercial loads are considered in the system. For the demonstration of the effectiveness of the proposed algorithm, 34-bus test system is considered as the case study. The proposed method results are shown that there is about 72% reduction in total power losses in the optimal configuration of DG units in the distribution system. It is observed that the total number of disturbed buses decreases to 4, which is equal to 12%, as the number of DG units increases. It can be seen that the total cost of the system is reduced from 36.250 to 31.824 M$, when the optimum number of DG units is increased from 1 to 5. The simulation results show the effectiveness of the proposed algorithm.
引用
收藏
页码:685 / 699
页数:14
相关论文
共 50 条
  • [41] Voltage sag state estimation for power distribution systems
    Wang, B
    Xu, WS
    Pan, ZC
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2005, 20 (02) : 806 - 812
  • [42] Applicability of Conservation Voltage Reduction to Distribution Networks with Photovoltaic Generation Considering Various Load Characteristics
    Masuta, Taisuke
    Asano, Shota
    Nguyen Hoang Viet
    [J]. 2017 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL AND INFORMATION SYSTEMS (ICIIS), 2017, : 1 - 6
  • [43] Applicability of conservation voltage reduction to distribution networks with photovoltaic generation considering various load characteristics
    [J]. 2017, Institute of Electrical and Electronics Engineers Inc., United States (2018-January):
  • [44] Optimal planning DG and BES units in distribution system considering uncertainty of power generation and time-varying load
    Khasanov, Mansur
    Kamel, Salah
    Awad, Ayman
    Jurado, Francisco
    [J]. TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2021, 29 (02) : 773 - 795
  • [45] Key Factors Influencing Voltage Recovery of DG Units in Distribution System
    Aziz, Tareq
    Saha, Tapan K.
    Mithulananthan, N.
    Krause, Olav
    [J]. 2012 22ND AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC): GREEN SMART GRID SYSTEMS, 2012,
  • [46] The voltage control on MV distribution networks with aggregated DG units (VPP)
    Bignucolo, F.
    Caldon, R.
    Prandoni, V.
    Spelta, S.
    Vezzola, M.
    [J]. PROCEEDINGS OF THE 41ST INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1 AND 2, 2006, : 187 - +
  • [47] Development of Analytical Technique for Optimal DG and Capacitor Allocation in Radial Distribution Systems Considering Load Variation
    Amin, Amal
    Kamel, Salah
    Selim, Ali
    Hasanien, Hany M.
    Al-Durra, Ahmed
    [J]. 45TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2019), 2019, : 2348 - 2353
  • [48] Optimal DG Deployment to Improve Voltage Stability Margin Considering Load Variation
    Saad, Mohamed Attia
    Abd el-Ghany, Hossam A.
    Azmy, Ahmed M.
    [J]. 2017 NINETEENTH INTERNATIONAL MIDDLE-EAST POWER SYSTEMS CONFERENCE (MEPCON), 2017, : 765 - 771
  • [49] Elimination of the Impact Produced by DG Units on the Voltage Profile of Distribution Networks
    Ouali, Saad
    Cherkaoui, Abdeljabbar
    [J]. JOURNAL OF APPLIED MATHEMATICS, 2020, 2020
  • [50] Optimization of Reactive Power Dispatch Considering DG Units Uncertainty by Dandelion Optimizer
    Alit, Mohammed Hamouda
    Soliman, Ahmed Mohammed Attiya
    Ahmed, Mohammed Fathy
    Adel, Ahmed Hassan
    [J]. INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2022, 12 (04): : 1805 - 1818