The feasibility of the 1-h high-sensitivity cardiac troponin T algorithm to rule-in and rule-out acute myocardial infarction in Thai emergency patients: An observational study

被引:4
|
作者
Ruangsomboon O. [1 ]
Mekavuthikul P. [1 ]
Chakorn T. [1 ]
Monsomboon A. [1 ]
Prapruetkit N. [1 ]
Surabenjawong U. [1 ]
Limsuwat C. [1 ]
Riyapan S. [1 ]
Chaisirin W. [1 ]
机构
[1] Department of Emergency Medicine, Siriraj Hospital, Mahidol University, 2 Wangland Rd., Bangkoknoi Bangkok
关键词
1-h hs-cTnT algorithm; Acute myocardial infarction; Chest pain; Emergency department; High-sensitivity cardiac troponin T;
D O I
10.1186/s12245-018-0204-9
中图分类号
学科分类号
摘要
Background: The 3-h high-sensitivity cardiac troponin T (hs-cTnT) algorithm is the most commonly used scheme to diagnose acute myocardial infarction. The 1-h hs-cTnT algorithm has recently been approved by the European Society of Cardiology as an alternative algorithm for earlier diagnosis. If the hs-cTnT test cannot discriminate the diagnosis of the patient at 1 h, the patient is defined as observational group. Their test must be repeated at 3 h. A high prevalence of this group may indicate a low clinical utility of the 1-h hs-cTnT algorithm. This study was aimed to estimate the proportion of the observational group in Thai emergency department (ED) patients and also the time to rule-in/out between both the algorithms. Methods: A historical control study was conducted in patients with chest pain for 1-12 h at the ED of Siriraj Hospital, Bangkok, Thailand. The study compared two groups: one prospective group of all patients evaluated with the 1-h hs-cTnT algorithm between June and September 2017 and one historical control group evaluated with the 3-h hs-cTnT algorithm between January and March 2017. Results: A total of 130 patients were included (3-h hs-cTnT algorithm group n = 65 and 1-h hs-cTnT algorithm group n = 65). Twelve patients [18.5% (95% CI 10.0-30.1)] were categorized as observational group in the 1-h hs-cTnT algorithm group. The mean rule-in/out times in the 3-h hs-cTnT algorithm and 1-h hs-cTnT algorithm groups were 238 min (SD 63.3) and 134 min (SD 68.5), respectively (both p < 0.001). The time to disposition was also shortened in the 1-h hs-cTnT algorithm group (p < 0.001). Multivariable regression analysis performed to identify and adjust for confounders among patient characteristics revealed no significant confounders. Conclusions: The use of the 1-h hs-cTnT algorithm in the ED resulted in an acceptable proportion in the observational group and a decreased time to rule-in/out compared with the 3-h hs-cTnT algorithm. © 2018 The Author(s).
引用
收藏
相关论文
共 50 条
  • [41] Adverse Outcomes 30 Days After Emergency Department Evaluation for Myocardial Infarction Determined Solely by High Sensitivity Troponin I Values for a 1-Hour Rule-Out/Rule-In Acute Myocardial Infarction Algorithm
    Nowak, R. M.
    McCord, J.
    Christenson, R. H.
    Jacobsen, G.
    Apple, F.
    Limkakeng, A.
    Peacock, W. F.
    DeFilippi, C.
    ANNALS OF EMERGENCY MEDICINE, 2019, 74 (04) : S3 - S3
  • [42] One-hour rule-out and rule-in of acute myocardial infarction using siemens sensitive cardiac Troponin I ultra
    Twerenbold, R.
    Meller, B.
    Rubini, M.
    Wildi, K.
    Mueller, M.
    Reichlin, T.
    Osswald, S.
    Mueller, C.
    EUROPEAN HEART JOURNAL, 2013, 34 : 74 - 74
  • [43] Diagnostic performance of cardiac Troponin I for early rule-in and rule-out of acute myocardial infarction: Results of a prospective multicenter trial
    Storrow, Alan B.
    Christenson, Robert H.
    Nowak, Richard M.
    Diercks, Deborah B.
    Singer, Adam J.
    Wu, Alan H. B.
    Kulstad, Erik
    LoVecchio, Frank
    Fromm, Christian
    Headden, Gary
    Potis, Tracie
    Hogan, Christopher J.
    Schrock, Jon W.
    Zelinski, Daniel P.
    Greenberg, Marna R.
    Ritchie, James C.
    Chamberlin, Janna S.
    Bray, Kurtis R.
    Rhodes, Daniel W.
    Trainor, Deirdre
    Holmes, Dawn
    Southwick, Paula C.
    CLINICAL BIOCHEMISTRY, 2015, 48 (4-5) : 254 - 259
  • [44] IS IT SAFE TO USE HIGH-SENSITIVITY CARDIAC TROPONIN T TO RULE OUT MYOCARDIAL INFARCTION AT PRESENTATION?
    Sandeman, Dennis
    Shah, Anoop
    Dinnel, Lorraine
    Andrews, Jack
    Roy, Bappa
    Wenham, Philip
    Campbell, Ken
    Jarvie, Mary
    Anand, Atul
    Cargill, Robert
    Francis, Mark
    Chapman, Andrew
    Mills, Nicholas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 241 - 241
  • [45] Use of historical high-sensitivity cardiac troponin T levels to rule out myocardial infarction
    Roos, Andreas
    Holzmann, Martin J.
    OPEN HEART, 2021, 8 (01):
  • [46] Economic Considerations of Early Rule-In/Rule-Out Algorithms for The Diagnosis of Myocardial Infarction in The Emergency Department Using Cardiac Troponin and Glycemic Biomarkers
    Shortt, Colleen
    Xie, Feng
    Whitlock, Richard
    Ma, Jinhui
    Clayton, Natasha
    Sherbino, Jonathan
    Hill, Stephen A.
    Pare, Guillaume
    McQueen, Matthew
    Mehta, Shamir R.
    Devereaux, P. J.
    Worster, Andrew
    Kavsak, Peter
    CLINICAL CHEMISTRY, 2017, 63 (02) : 593 - 602
  • [47] Prognostic impact of stepwise 0/1/3h rule-out of myocardial infarction using high-sensitivity troponin T
    Lehmacher, J.
    Guo, L.
    Toprak, B.
    Soerensen, N. A.
    Haller, P. M.
    Schock, A.
    Hartikainen, T. S.
    Westermann, D.
    Zeller, T.
    Blankenberg, S.
    Neumann, J. T.
    Twerenbold, R.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [48] The Value of Prehospital and Inhospital High-Sensitivity Troponin T Analysis for Rapid Rule in and Rule out of Patients with Acute Myocardial Infarction
    Stengaard, Carsten
    Sorensen, Jacob T.
    Ladefoged, Soren A.
    Christensen, Erika F.
    Lassen, Jens F.
    Botker, Hans Erik
    Terkelsen, Christian J.
    Thygesen, Kristian
    CIRCULATION, 2012, 126 (21)
  • [49] Combining presentation high-sensitivity cardiac troponin I and glucose measurements to rule-out an acute myocardial infarction in patients presenting to emergency department with chest pain
    Greenslade, J. H.
    Kavsak, P.
    Parsonage, W.
    Shortt, C.
    Than, M.
    Pickering, J. W.
    Aldous, S.
    Cullen, L.
    CLINICAL BIOCHEMISTRY, 2015, 48 (4-5) : 288 - 291
  • [50] Comparison of a single high-sensitivity cardiac troponin T measurement with the HEART score for rapid rule-out of acute myocardial infarction in a primary care emergency setting: a cohort study
    Johannessen, Tonje R.
    Atar, Dan
    Vallersnes, Odd Martin
    Larstorp, Anne Cecilie K.
    Mdala, Ibrahimu
    Halvorsen, Sigrun
    BMJ OPEN, 2021, 11 (02):