Twisting and constriction of a HeartMate II driveline in the area of a repair site

被引:0
|
作者
Sven Maier
Friedhelm Beyersdorf
Christoph Benk
机构
[1] Faculty of Medicine,Department of Cardiovascular Surgery, Heart Center Freiburg University
[2] University of Freiburg,undefined
来源
Journal of Artificial Organs | 2020年 / 23卷
关键词
Left ventricular assist device; Driveline repair; Driveline exchange;
D O I
暂无
中图分类号
学科分类号
摘要
The driveline’s durability is crucial for optimal long-term support with a left-ventricular assist device (LVAD). The incidence of percutaneous driveline fracture after HeartMate II LVAD implantation is low. For the first time, we describe a patient with an already repaired driveline and a massive constriction and twisting of the driveline in the area of the repair site. This dramatic finding necessitates a renewed exchange of the external part of the driveline by the manufacturer. Due to the increasing number of patients with elongated LVAD support, the stability of the driveline and possible repairs including the replacement of the driveline are becoming more and more important. Our case report describes a possible serious late complication after replacement of the driveline, shows possible risks for this development, and describes the necessity of a prophylactic X-ray examination of repaired drivelines to detect such complications as early as possible.
引用
收藏
页码:371 / 373
页数:2
相关论文
共 50 条
  • [21] Endovascular repair of a HeartMate II Left ventricular assist device
    Dhesi, Pavittarpaul
    Sadiq, Immad
    Gluck, Jason
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (11): : 1198 - 1199
  • [22] Modified HeartMate II Driveline Externalization Technique Significantly Decreases Incidence of Infection and Improves Long-Term Survival
    Singh, Ajeet
    Russo, Mark J.
    Valeroso, Tracy B.
    Anderson, Allen S.
    Rich, Jonathan D.
    Jeevanandam, Valluvan
    Akhter, Shahab A.
    ASAIO JOURNAL, 2014, 60 (06) : 613 - 616
  • [23] Reduction in Driveline Infection Rates: Results from the HeartMate II Multicenter Silicone-Skin-Interface (SSI) Registry
    Dean, D.
    Ewald, G. A.
    Tatooles, A.
    Sheridan, B. C.
    Brewer, R. J.
    Caldeira, C.
    Kallel, F.
    Farrar, D. J.
    Akhter, S. A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (04): : S11 - S11
  • [24] Internal driveline damage under the costal margin several years after HeartMate II implant: a series of three cases
    Ogawa, Mitsugu
    Masood, Muhammad F.
    Ewald, Gregory A.
    Vader, Justin M.
    LaRue, Shane J.
    Cheng, Allen
    Balsara, Keki R.
    Itoh, Akinobu
    JOURNAL OF ARTIFICIAL ORGANS, 2018, 21 (03) : 359 - 362
  • [25] Modified HeartMate II Driveline Externalization Technique Significantly Decreases Incidence of Infection and Improves Long-Term Survival
    Akhter, S. A.
    Russo, M. J.
    Singh, A.
    Valeroso, T. B.
    Johnson, E. M.
    Anderson, A. S.
    Fedson, S. E.
    Kim, G.
    Rich, J.
    Jeevanandam, V.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2012, 31 (04): : S20 - S20
  • [26] Impact of chlorhexidine gluconate intolerance on driveline infection during chronic HeartMate II left ventricular assist device support
    Son, Andre Y.
    Stein, Louis H.
    DeAnda, Abe
    Katz, Stuart D.
    Smith, Deane E.
    Reyentovich, Alex
    Balsam, Leora B.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2016, 39 (11): : 570 - 574
  • [27] Internal driveline damage under the costal margin several years after HeartMate II implant: a series of three cases
    Mitsugu Ogawa
    Muhammad F. Masood
    Gregory A. Ewald
    Justin M. Vader
    Shane J. LaRue
    Allen Cheng
    Keki R. Balsara
    Akinobu Itoh
    Journal of Artificial Organs, 2018, 21 : 359 - 362
  • [28] Repair of Left Ventricular Assist Device Driveline Damage Directly at the Transcutaneous Exit Site
    Schima, Heinrich
    Stoiber, Martin
    Schloeglhofer, Thomas
    Hartner, Zeno
    Haberl, Thomas
    Zimpfer, Daniel
    ARTIFICIAL ORGANS, 2014, 38 (05) : 422 - 425
  • [29] Twisting of HeartMate II outflow graft 2.5 years after implantation–HM2 is still ongoing
    Hiroaki Sakamoto
    Hideyuki Kato
    Toru Tsukada
    Bryan J. Mathis
    Yuji Hiramatsu
    Journal of Artificial Organs, 2024, 27 : 69 - 72
  • [30] Twisting of HeartMate II outflow graft 2.5 years after implantation-HM2 is still ongoing
    Sakamoto, Hiroaki
    Kato, Hideyuki
    Tsukada, Toru
    Mathis, Bryan J.
    Hiramatsu, Yuji
    JOURNAL OF ARTIFICIAL ORGANS, 2024, 27 (01) : 69 - 72