Reliability and reproducibility of the DICART device to assess capillary refill time: a bench and in-silico study

被引:0
|
作者
Matthias Jacquet-Lagrèze
Christophe Saint-Jean
Thierry Bouët
Sébastien Reynaud
Martin Ruste
Jean-Luc Fellahi
机构
[1] Hospices Civils de Lyon,Service d’Anesthésie
[2] Hôpital Louis Pradel,Réanimation
[3] Laboratoire CarMeN,Laboratoire Mathématiques
[4] Inserm U1060,undefined
[5] Université Claude Bernard Lyon 1,undefined
[6] Faculté de médecine Lyon-Est,undefined
[7] Université de la Rochelle,undefined
[8] DiCARTECH? Company,undefined
关键词
Capillary refill time; Device; Reproducibility; Acute circulatory failure;
D O I
暂无
中图分类号
学科分类号
摘要
Capillary refill time (CRT) is an important indicator of peripheral perfusion with a strong prognostic value, but it is sensitive to environmental factors and numerous measurement methods are reported in the litterature. DiCARTECH has developed a device that assesses CRT. We sought to investigate the robustness of the device and the reproducibility of the algorithm in a bench and in-silico study. We used the video acquired from a previous clinical study on healthy volunteers. For the bench study, the measurement process was performed by a robotic system piloted by a computer that analyzed 250 times nine previously acquired videos. For the in-silico study, we used 222 videos to test the algorithm’s robustness. We created 30 videos from each video with a large blind spot and used the “color jitter” function to create a hundred videos from each video. In the bench study, the coefficient of variation was 11% (95%CI: 9–13). The correlation with human-measured CRT was good (R2 = 0.91, P < 0.001). In the in-silico study, for the blind spotted video, the coefficient of variation was 13% (95%CI: 10–17). For the color-jitter modified video the coefficient of variation was 62% (95%CI: 55–70). We confirmed the ability of the DiCART™ II device to perform multiple measurements without mechanical or electronic dysfunction. The precision and reproducibility of the algorithm are compatible with the assessment of clinical small changes in CRT.
引用
收藏
页码:1409 / 1412
页数:3
相关论文
共 50 条
  • [31] Spatial reproducibility of complex fractionated atrial electrograms depending on the direction and configuration of bipolar electrodes: a patient specific in-silico left atrial modeling study
    Song, J. S.
    Hwang, M.
    Lee, Y. S.
    Lee, J. K.
    Li, C.
    Jeoung, B.
    Lee, M. H.
    Shim, E. B.
    Pak, H. N.
    [J]. EUROPEAN HEART JOURNAL, 2015, 36 : 1073 - 1073
  • [32] Low temperature increases capillary blood refill time following mechanical fingertip compression of healthy volunteers: prospective cohort study
    Shinozaki, Koichiro
    Capilupi, Michael J.
    Saeki, Kota
    Hirahara, Hideaki
    Horie, Katsuyuki
    Kobayashi, Naoki
    Weisner, Steve
    Kim, Junhwan
    Lampe, Joshua W.
    Becker, Lance B.
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2019, 33 (02) : 259 - 267
  • [33] Low temperature increases capillary blood refill time following mechanical fingertip compression of healthy volunteers: prospective cohort study
    Koichiro Shinozaki
    Michael J. Capilupi
    Kota Saeki
    Hideaki Hirahara
    Katsuyuki Horie
    Naoki Kobayashi
    Steve Weisner
    Junhwan Kim
    Joshua W. Lampe
    Lance B. Becker
    [J]. Journal of Clinical Monitoring and Computing, 2019, 33 : 259 - 267
  • [34] Capillary refill time is a predictor of short-term mortality for adult patients admitted to a medical department: an observational cohort study
    Mrgan, Monija
    Rytter, Dorte
    Brabrand, Mikkel
    [J]. EMERGENCY MEDICINE JOURNAL, 2014, 31 (12) : 954 - 958
  • [35] Agreement between Capillary Refill Time measured at Finger and Earlobe sites in different positions: a pilot prospective study on healthy volunteers
    La Via, Luigi
    Sanfilippo, Filippo
    Continella, Carlotta
    Triolo, Tania
    Messina, Antonio
    Robba, Chiara
    Astuto, Marinella
    Hernandez, Glenn
    Noto, Alberto
    [J]. BMC ANESTHESIOLOGY, 2023, 23 (01)
  • [36] Agreement between Capillary Refill Time measured at Finger and Earlobe sites in different positions: a pilot prospective study on healthy volunteers
    Luigi La Via
    Filippo Sanfilippo
    Carlotta Continella
    Tania Triolo
    Antonio Messina
    Chiara Robba
    Marinella Astuto
    Glenn Hernandez
    Alberto Noto
    [J]. BMC Anesthesiology, 23
  • [37] A low peripheral perfusion index can accurately detect prolonged capillary refill time during general anesthesia: A prospective observational study
    Iizuka, Yusuke
    Yoshinaga, Koichi
    Nakatomi, Takeshi
    Takahashi, Kyosuke
    Yoshida, Kyoko
    Sanui, Masamitsu
    [J]. SAUDI JOURNAL OF ANAESTHESIA, 2023, 17 (01) : 33 - 38
  • [38] The Use of Lactate-Capillary Refill Time Product as Novel Index for Tissue Perfusion in Patients with Abdominal Sepsis: A Prospective Observational Study
    Shaker, Ahmed
    Hasanin, Ahmed
    Nagy, Mostafa
    Mostafa, Maha
    Fouad, Ahmed Z.
    Mohamed, Hassan
    Abdallah, Ahmed S.
    Elsayad, Mohamed
    [J]. INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2022, 15 : 7443 - 7448
  • [39] IS BEDSIDE CLINICAL EXAMLNATION OF CAPILLARY REFILL TIME REPRODUCIBLE IN CRITICALLY ILL PATIENTS BETWEEN DIFFERENT OBSERVERS? AN INTER-RATER VARIABILITY STUDY
    Lima, A.
    van Genderen, M.
    Boerstra, T.
    Bakker, J.
    van Bommel, J.
    [J]. INTENSIVE CARE MEDICINE, 2011, 37 : S215 - S215
  • [40] A Novel Device Using the Nordic Hamstring Exercise to Assess Eccentric Knee Flexor Strength: A Reliability and Retrospective Injury Study
    Opar, David A.
    Piatkowski, Timothy
    Williams, Morgan D.
    Shield, Anthony J.
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2013, 43 (09): : 636 - 640