Evaluation of absorbed dose in thyroid follicles due to short-lived iodines irradiation using the Monte Carlo method

被引:0
|
作者
L. Campos
A. Amaral
N. Colas-Linhart
E. Hindié
机构
[1] GERAR,
[2] Grupo de Estudos em Radioproteç?o e Radioecologia,undefined
[3] Department of Nuclear Energy,undefined
[4] UFPE; Laboratoire de Chimie et Biophysique des Traceurs,undefined
[5] Faculté de Médecine Xavier Bichat,undefined
[6] GERAR,undefined
[7] Grupo de Estudos em Radioproteç?o e Radioecologia,undefined
[8] Department of Nuclear Energy,undefined
[9] UFPE,undefined
[10] Laboratoire de Chimie et Biophysique des Traceurs,undefined
[11] Faculté de Médecine Xavier Bichat,undefined
[12] Service de Médecine Nucléaire,undefined
[13] Hôpital Saint-Antoine,undefined
关键词
Iodine; Iodine Deficiency; Follicular Cell; Thyroid Cell; Thyroid Follicle;
D O I
暂无
中图分类号
学科分类号
摘要
Thyroid cells are arranged in spheres called follicles of different sizes, in which most of the iodine in the body concentrates. For dose assessment in follicles, it is necessary to consider specific emissions of iodine isotopes in the calculation. Hence, the aim of this work was to evaluate the contribution of 131I and short-lived iodines to the absorbed dose in thyroid cells. Thus, the interaction of emissions from isotopes with follicles was carried out using the MCNP4C code. The results showed that the contribution of short-lived iodines for absorbed dose per disintegration is about 70%.
引用
收藏
页码:635 / 638
页数:3
相关论文
共 37 条
  • [21] Evaluation of 18F-FDG absorbed dose ratios in percent in adult and pediatric reference phantoms using DoseCalcs Monte Carlo platform
    El Ghalbzouri, Tarik
    El Bardouni, Tarek
    El Bakkali, Jaafar
    Satti, Hicham
    Nouayti, Abdelhamid
    Berriban, Iman
    Yerrou, Randa
    Arectout, Assia
    Hadouachi, Maryam
    APPLIED RADIATION AND ISOTOPES, 2025, 218
  • [22] Comparison and Evaluation of Different Tallies for Absorbed Dose Calculation of Palladium-103 Source Brachytherapy of MED3633 Model in Water Phantom Using Monte Carlo Method
    Ahmadi, Ome Leila
    Tavakoli-Anbaran, Hossein
    AFRICAN REVIEW OF PHYSICS, 2016, 11 : 75 - 79
  • [23] Comprehensive Monte Carlo evaluation of absorbed dose in computed tomography using water and polymethyl methacrylate cylinders from 1 cm to 50 cm in diameter
    Zhou, H.
    Boone, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2430 - 2431
  • [24] ASSESSMENT OF THE ABSORBED DOSE IN THE THYROID, AS A CRITICAL ORGAN IN SCINTIGRAPHIES WITH 123I AND Na99mTcO4-, USING MONTE CARLO METHODS AND BIOKINETIC MODELS
    Martins, Bruno
    Bento, Joana
    Alves, Francisco
    Colarinha, Paula
    Teixeira, Nuno
    Teles, Pedro
    Vaz, Pedro
    ICEM15: 15TH INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS, 2012,
  • [25] Re-evaluation of 18F-FDG absorbed and effective dose in adult and pediatric phantoms using DoseCalcs Monte Carlo platform: a validation study
    El Ghalbzouri, Tarik
    El Bardouni, Tarek
    El Bakkali, Jaafar
    El Hajjaji, Otman
    Satti, Hicham
    Arectout, Assia
    Hadouachi, Maryam
    Yerru, Randa
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024,
  • [26] 3D absorbed dose calculations based on SPECT:: Evaluation for 111-In/90-Y therapy using Monte Carlo simulations.
    Ljungberg, M
    Frey, E
    Sjögreen, K
    Liu, XW
    Dewaraja, Y
    Strand, SE
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2003, 18 (01) : 99 - 107
  • [27] Analytical solution of absorbed dose for spherical source-target geometries using Monte Carlo derived point-kernels: An application to 131I thyroid microdosimetry
    Eterovic, D.
    Markovic, V.
    Stipanovic, P.
    Punda, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S434 - S435
  • [28] Absorbed dose calculation for a realistic CT-derived mouse phantom irradiated with a standard Cs-137 cell irradiator using a Monte Carlo method
    Entezam, Amir
    Fielding, Andrew
    Bradley, David
    Fontanarosa, Davide
    PLOS ONE, 2023, 18 (02):
  • [29] Taking into account absorbed doses in tooth enamel due to internal irradiation of human body by radioactive cesium isotopes at analysis EPR dosimetry data: Calculation by Monte-Carlo method
    Borysheva, N.
    Ivannikov, A.
    Tikunov, D.
    Orlenko, S.
    Skvortsov, V.
    Stepanenko, V.
    Hoshi, M.
    RADIATION MEASUREMENTS, 2007, 42 (6-7) : 1190 - 1195
  • [30] Experimental and Computational Dose Rate Evaluation Using SN and Monte Carlo Method for a Packaged 241AmBe Neutron Source
    Wang, Meng-Jen
    Sjoden, Glenn E.
    NUCLEAR SCIENCE AND ENGINEERING, 2021, 195 (11) : 1154 - 1175