Detection and assessment of dust mite allergens in an indoor environment in Anhui, China

被引:0
|
作者
Qiqi Xue
Minghui Zou
Junjie Guo
Qiao Teng
Qiqi Zhang
Lingwei Sheng
Sijia Xu
Can Fang
Ning Yao
Yuanyuan Li
Jinhong Zhao
机构
[1] Wannan Medical College,Department of Medical Parasitology
[2] Qiqihar Medical College,Department of Medical Parasitology
[3] Wannan Medical College,School of Clinical Medicine
[4] Wannan Medical College,Medical Laboratory Science
[5] Wannan Medical College,School of Public Health
[6] Wannan Medical College,Anhui Province Key Laboratory of Biological Macromlecules Research
关键词
Dust mite; Air conditioner dust; Floor dust; ELISA questionnaire;
D O I
暂无
中图分类号
学科分类号
摘要
Dust in the home environment is thought to be a potential trigger for increasing allergic diseases, such as allergic rash, rhinitis, asthma, and other conditions, associated with dust mites. To verify the status of dust mite prevalence in indoor surroundings, we collected 189 dust samples from the air conditioner filters (n = 75) and floors (n = 114) of households, schools, and hotels in the Anhui area, China. All samples were measured for dust mite breeding rate and breeding density under light microscopy and analyzed for dust mite species Dermatophagoides farinae 1 (Der f 1) and Dermatophagoides pteronyssinus 1 (Der p 1) allergen using enzyme-linked immunosorbent assay (ELISA). The dust mite breeding rates were 34.67% (26/75) and 20.18% (23/114), respectively, in the dust samples from the floor and air conditioning filters. The breeding density was the highest in households (10/g), followed by schools (9/g) and hotels (4/g). ELISA indicated that the allergen threshold (2.0 µg/g dust) of Der f 1 was exceeded in only two samples and Der p 1 in one sample. Additionally, a questionnaire was used to investigate the health knowledge on allergic diseases involved in indoor facilities, finding that most allergy sufferers were aware that indoor dust might be responsible for their conditions. The findings suggest that regular maintenance of indoor hygiene and cleaning of air-conditioning filters should reduce the risks of exposure to indoor allergens.
引用
收藏
页码:3045 / 3055
页数:10
相关论文
共 50 条
  • [1] Detection and assessment of dust mite allergens in an indoor environment in Anhui, China
    Xue, Qiqi
    Zou, Minghui
    Guo, Junjie
    Teng, Qiao
    Zhang, Qiqi
    Sheng, Lingwei
    Xu, Sijia
    Fang, Can
    Yao, Ning
    Li, Yuanyuan
    Zhao, Jinhong
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2023, 30 (02) : 3045 - 3055
  • [2] House dust mite allergens and nitrated products:Identification and risk assessment in indoor dust
    Fan Xu
    Jingyi Tian
    Fangxing Yang
    Journal of Environmental Sciences, 2023, 124 (02) : 198 - 204
  • [3] House dust mite allergens and nitrated products: Identification and risk assessment in indoor dust
    Xu, Fan
    Tian, Jingyi
    Yang, Fangxing
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2023, 124 : 198 - 204
  • [4] DUST-MITE ALLERGENS IN THE OFFICE ENVIRONMENT
    JANKO, M
    GOULD, DC
    VANCE, L
    STENGEL, CC
    FLACK, J
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1995, 56 (11): : 1133 - 1140
  • [5] Exposition and sensitisation to indoor allergens, house dust mite allergen and cat allergens
    Jovanovic, S
    Felder-Kennel, A
    Gabrio, T
    Kouros, B
    Link, B
    Maisner, V
    Piechotowski, I
    Schick, KH
    Schrimpf, M
    Schwenk, M
    Weidner, U
    Zöllner, I
    GESUNDHEITSWESEN, 2003, 65 (07) : 457 - 463
  • [6] Effect of zeolites on bacteria, moulds and dust mite allergens in household dust and indoor air
    Klanova, K
    CHIMICA OGGI-CHEMISTRY TODAY, 2002, 20 (05) : 56 - 59
  • [7] Describing fluctuating indoor aerosol dust measurements with application to house dust mite allergens
    van Boven, F. E.
    de Jong, N. W.
    Loomans, M. G. L. C.
    Braunstahl, G. J.
    van Wijk, R. Gerth
    Arends, L. R.
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [8] Describing fluctuating indoor aerosol dust measurements with application to house dust mite allergens
    F. E. van Boven
    N. W. de Jong
    M. G. L. C. Loomans
    G. J. Braunstahl
    R. Gerth van Wijk
    L. R. Arends
    Scientific Reports, 10
  • [9] Impact of environmental factors and bacterial interactions on dust mite allergens in different indoor dust
    Li, Zimeng
    Zheng, Na
    An, Qirui
    Li, Xiaoqian
    Sun, Siyu
    Zhang, Wenhui
    Ji, Yining
    Wang, Sujing
    Li, Pengyang
    SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 844
  • [10] ELIMINATION OF HOUSE DUST MITE EXCRETA, THE CARRIERS OF ALLERGENS IN THE INDOOR AIR
    BISCHOFF, E
    FISCHER, A
    LIEBENBERG, B
    PRESENT AND FUTURE OF INDOOR AIR QUALITY, 1989, 860 : 363 - 370