How to treat proximal and middle one-third humeral shaft fractures: the role of helical plates

被引:5
|
作者
Nicolaci G. [1 ]
Maes V. [2 ]
Lollino N. [3 ]
Putzeys G. [4 ]
机构
[1] Università degli Studi di Torino, Via Gianfranco Zuretti 29, Turin
[2] Department of Orthopaedic Surgery, University Hospitals Leuven, Leuven
[3] Ospedale Civile E. Agnelli, SC Ortopedia e Traumatologia, Via Brigata Cagliari 39, Pinerolo
[4] Department of Orthopaedic Surgery, AZ Groeninge Hospital, President Kennedylaan 4, Kortrijk
关键词
Complex humeral fractures; Deltoid tuberosity; Diaphyseal humeral fractures; Helical plates;
D O I
10.1007/s12306-022-00748-9
中图分类号
学科分类号
摘要
Purpose: To evaluate the outcomes of patients affected by proximal and middle one-third humeral shaft fractures treated with humeral helical plates. Material and methods: From October 2016 to June 2020, twenty-four (twenty women, four men) underwent humeral reduction and fixation with humeral helical plates (A.L.P.S.® Proximal Humeral Plating System, Zimmer Biomet) that preserve deltoid muscle insertion and reduce the risk of iatrogenic radial nerve injury. At one and six months after surgery, standard antero-posterior and lateral radiographs were obtained, and at last follow-up (eighteen months on average), clinical evaluation was performed through range of motion assessment, Constant score and DASH score questionnaires. Only descriptive statistical analysis was conducted. Results: At six months, all fractures have healed. At last follow-up (average eighteen months, 13–28) mean Constant score was 71 (range 33–96), mean Dash score was 19.2 (range 1.7–63). The average range of motion was calculated as follows: flexion 137.8° (range 90–180); abduction 125.8° (range 85–180°); external rotation 55° (range 20–80°), internal rotation at L3 (range between scapulae-trochanter). Three patients experienced temporary radial nerve palsy from injury, while in one case, a temporary iatrogenic palsy occurred. Conclusions: In our opinion, the helical plate may be an effective surgical tool for management of proximal and middle one-third diaphyseal humeral fractures. The humeral helical plate allows stable fixation avoiding the deltoid tuberosity proximally and radial nerve distally, thus increasing the possibility of rapid functional recovery after surgery. © 2022, The Author(s), under exclusive licence to Istituto Ortopedico Rizzoli.
引用
收藏
页码:231 / 238
页数:7
相关论文
共 50 条
  • [21] Minimally invasive plating osteosynthesis of proximal humeral shaft fractures with long PHILOS plates
    Brunner, A.
    Thormann, S.
    Babst, R.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2012, 24 (4-5): : 302 - 311
  • [22] Proximal third humeral shaft fractures fixed with long helical PHILOS plates in elderly patients: benefit of pre-contouring plates on a 3D-printed model—a retrospective study
    Qiuke Wang
    Jian Hu
    Junjie Guan
    Yunfeng Chen
    Lei Wang
    Journal of Orthopaedic Surgery and Research, 13
  • [23] Proximal third humeral shaft fractures fixed with long helical PHILOS plates in elderly patients: benefit of pre-contouring plates on a 3D-printed model-a retrospective study
    Wang, Qiuke
    Hu, Jian
    Guan, Junjie
    Chen, Yunfeng
    Wang, Lei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [24] Minimally invasive plating osteosynthesis (MIPO) of middle and distal third humeral shaft fractures
    Zhiquan, An
    Bingfang, Zeng
    Yeming, Wang
    Chi, Zhang
    Peiyan, Huang
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (09) : 628 - 633
  • [25] Biomechanical testing of osteosynthetic locking plates for proximal humeral shaft fractures - a systematic literature review
    Halbauer, Christian
    Capanni, Felix
    Bertusch, Isabel
    Paech, Andreas
    Merkle, Tobias
    Da Silva, Tomas
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2023, 68 (06): : 553 - 561
  • [26] Implant choice for Weber C ankle fractures: are one-third tubular plates adequate?
    Bechtel, Christopher P.
    Walsh, Michael
    Davidovitch, Roy I.
    Egol, Kenneth A.
    CURRENT ORTHOPAEDIC PRACTICE, 2011, 22 (01): : 64 - 70
  • [27] Locking Plates versus Locking Intramedullary Nails Fixation of Proximal Humeral Fractures Involving the Humeral Shaft: A Retrospective Cohort Study
    Song, Hui
    He, Tao
    Guo, Hui-Min Y.
    Li, Zhan-Yu
    Wei, Min
    Zhang, Chao
    Dong, Yu-Qi
    MEDICAL SCIENCE MONITOR, 2020, 26 : e922598
  • [28] Treatment of Middle Third Humeral Shaft Fractures with Anteromedial Plate Osteosynthesis through an Anterolateral Approach
    Kumar, B. S.
    Soraganvi, P.
    Satyarup, D.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2016, 10 (01) : 38 - 43
  • [29] Proximal third humeral shaft fractures-A fracture entity not fully characterized by conventional AO classification
    Stedtfeld, H. W.
    Biber, R.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 : S54 - S59
  • [30] A Biomechanical Comparison of One-Third Tubular Plates Versus Periarticular Plates for Fixation of Osteoporotic Distal Fibula Fractures
    Davis, Adrian T.
    Israel, Heidi
    Cannada, Lisa K.
    Bledsoe, J. Gary
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2013, 27 (09) : e201 - e207