Analysis of the concurrent validity and reliability of five common clinical goniometric devices

被引:0
|
作者
Sirirat Kiatkulanusorn
Nongnuch Luangpon
Wirasinee Srijunto
Sarawoot Watechagit
Krittipat Pitchayadejanant
Sireetorn Kuharat
O. Anwar Bég
Bhornluck Paepetch Suato
机构
[1] Burapha University,Department of Physical Therapy, Faculty of Allied Health Sciences
[2] Mahidol University,Faculty of Engineering
[3] Burapha University International College,Corrosion Lab, Multi
[4] Burapha University,Physical Engineering Sciences Group (MPESG), Department of Mechanical/Aeronautical Engineering
[5] Salford University,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Measurement errors play an important role in the development of goniometric equipment, devices used to measure range of motion. Reasonable validity and reliability are critical for both the device and examiner before and after to testing in human subjects. The objective is to evaluate the concurrent validity and reliability of five different clinical goniometric devices for the purpose of establishing an acceptable measurement error margin for a novel device. We explored the validity and inter- and intrarater reliability scores of five goniometric devices namely (i) the universal goniometer (UG), a two-armed hand-held goniometer, (ii) the inclinometer (IC), featuring a single base, fluid level, and gravity-weighted inclinometer, (iii) the digital inclinometer (DI), functioning as both a DI and dynamometer, (iv) the smartphone application (SA), employing gyroscope-based technology within a smartphone platform application and (v) the modified inclinometer (MI), a gravity pendulum-based inclinometer equipped with a specialized fixing apparatus. Measurements were obtained at 12 standard angles and 8 human shoulder flexion angles ranging from 0° to 180°. Over two testing sessions, 120 standardized angle measurements and 160 shoulder angle measurements from 20 shoulders were repetitively taken by three examiners for each device. The intraclass correlation coefficient (ICC), standard error of measurement (SEM), and minimal detectable change (MDC) were calculated to assess reliability and validity. Concurrent validity was also evaluated through the execution of the 95% limit of agreement (95% LOA) and Bland–Altman plots, with comparisons made to the UG. The concurrent validity for all device pairs was excellent in both study phases (ICC > 0.99, 95% LOA − 4.11° to 4.04° for standard angles, and − 10.98° to 11.36° for human joint angles). Inter- and intrarater reliability scores for standard angles were excellent across all devices (ICC > 0.98, SEM 0.59°–1.75°, MDC 1°–4°), with DI showing superior reliability. For human joint angles, device reliability ranged from moderate to excellent (ICC 0.697–0.975, SEM 1.93°–4.64°, MDC 5°–11° for inter-rater reliability; ICC 0.660–0.996, SEM 0.77°–4.06°, MDC 2°–9° for intra-rater reliability), with SA demonstrating superior reliability. Wider angle measurement however resulted in reduced device reliability. In conclusion, our study demonstrates that it is essential to assess measurement errors independently for standard and human joint angles. The DI is the preferred reference for standard angle testing, while the SA is recommended for human joint angle testing. Separate evaluations across the complete 0°–180° range offer valuable insights.
引用
收藏
相关论文
共 50 条
  • [1] Analysis of the concurrent validity and reliability of five common clinical goniometric devices
    Kiatkulanusorn, Sirirat
    Luangpon, Nongnuch
    Srijunto, Wirasinee
    Watechagit, Sarawoot
    Pitchayadejanant, Krittipat
    Kuharat, Sireetorn
    Beg, O. Anwar
    Suato, Bhornluck Paepetch
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [2] The reliability and concurrent validity of goniometric and visual estimation in participants with unilateral shoulder pain
    Bousquet, Amy I.
    Aronsen, Leif E.
    Atlas, Jenna M.
    Corrado, Brianna M.
    Pijloo, Harrison
    Queiroz, Nicholas A.
    Austin, Matthew
    Riley, Sean P.
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2024, 40 : 307 - 314
  • [3] RELIABILITY AND VALIDITY OF GONIOMETRIC MEASUREMENTS AT THE KNEE
    GOGIA, PP
    BRAATZ, JH
    ROSE, SJ
    NORTON, BJ
    PHYSICAL THERAPY, 1987, 67 (02): : 192 - 195
  • [4] VALIDITY AND RELIABILITY OF GONIOMETRIC MEASUREMENTS AT THE KNEE
    GOGIA, P
    BRAATZ, JH
    ROSE, SJ
    PHYSICAL THERAPY, 1985, 65 (05): : 700 - 700
  • [5] Absolute Reliability and Concurrent Validity of the Modified Goniometric Platform for Measuring Trunk Rotation in the Sitting Position
    Gao, Jianhong
    Thung, Jin Seng
    Wei, Shanshan
    Pavlu, Dagmar
    Chee, Chen Soon
    Ramasamy, Yuvaraj
    Ali, Azril Syazwan Bin Mohd
    Yatim, Rosnah Binti Mat
    APPLIED SCIENCES-BASEL, 2022, 12 (17):
  • [6] Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
    Al-Amri, Mohammad
    Nicholas, Kevin
    Button, Kate
    Sparkes, Valerie
    Sheeran, Liba
    Davies, Jennifer L.
    SENSORS, 2018, 18 (03):
  • [7] THE INFLUENCE OF SELECTED VARIABLES ON GONIOMETRIC RELIABILITY AND VALIDITY
    WINGATE, L
    FISH, D
    PHYSICAL THERAPY, 1984, 64 (05): : 736 - 736
  • [8] Lower extremity range of motion and alignment: A reliability and concurrent validity study of goniometric and three-dimensional motion analysis measurement
    Ore, Viktor
    Nasic, Salmir
    Riad, Jacques
    HELIYON, 2020, 6 (08)
  • [9] Common Vertical Jump and Reactive Strength Index Measuring Devices: A Validity and Reliability Analysis
    Montalvo, Samuel
    Gonzalez, Matthew P.
    Dietze-Hermosa, Martin S.
    Eggleston, Jeffrey D.
    Dorgo, Sandor
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2021, 35 (05) : 1234 - 1243
  • [10] Reliability and validity of goniometric and photographic measurements of clavicular tilt angle
    Ha, Sung-min
    Kwon, Oh-yun
    Weon, Jong-hyuck
    Kim, Moon-hwan
    Kim, Su-jung
    MANUAL THERAPY, 2013, 18 (05) : 367 - 371