Impact of real-time virtual sonography, a coordinated sonography and MRI system that uses an image fusion technique, on the sonographic evaluation of MRI-detected lesions of the breast in second-look sonography

被引:0
|
作者
Shogo Nakano
Junko Kousaka
Kimihito Fujii
Kyoko Yorozuya
Miwa Yoshida
Yukako Mouri
Miwa Akizuki
Rie Tetsuka
Takahito Ando
Takashi Fukutomi
Yukihiko Oshima
Junko Kimura
Tsuneo Ishiguchi
Osamu Arai
机构
[1] Aichi Medical University,Division of Breast and Endocrine Surgery, Department of Surgery
[2] Aichi Medical University,Department of Radiology
[3] Hitachi Aloka Medical,Ultrasound System Group, Department of Research & Development, Medical System Engineering Division 2
[4] Ltd,undefined
来源
关键词
Breast cancer; MRI-detected lesion; Second-look sonography; Supine MRI; Real-time virtual sonography; Image fusion;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to verify the utility of second-look sonography using real-time virtual sonography (RVS)—a coordinated sonography with an MRI system that uses an image fusion technique with magnetic navigation—on the sonographic evaluation of MRI-detected lesions of the breast. Of the 196 consecutive patients who were examined with breast MRI in our hospital from 2006 to 2009, those patients who underwent second-look sonography to identify MRI-detected lesions were enrolled in this study. MRI was performed using a 1.5-T imager with the patient in a supine position. To assess the efficacy benefits of RVS, the correlations between lesion detection rates, MRI features, distribution, and histopathological classification on second-look sonography using conventional B-mode or RVS were analyzed. Of the 196 patients, 55 (28 %) demonstrated 67 lesions initially detected by MRI, followed by second-look sonography. Of the 67 MRI-detected lesions, 18 (30 %) were identified with second-look sonography using conventional B-mode alone, whereas 60 (90 %) lesions were detected with second-look sonography using RVS (p < 0.001). The detection rates of 16 focal lesions, 46 mass lesions, 16 lesions sized <5 mm, 45 lesions sized 5–10 mm, 26 lesions situated within the mammary gland, 41 lesions situated around mammary fascia, 24 malignant lesions, and 43 benign lesions were, respectively, 25, 26, 25, 24, 42, 17, 33, and 23 % by conventional B-mode, and were significantly higher, respectively, at 94, 89, 94, 89, 88, 90, 92, and 88 % by RVS. Of the seven lesions with no sonographic correlates, five could be biopsied by marking MRI information onto the body surface using RVS. Overall, 65 of 67 (97 %) MRI-detected lesions were confirmed by histopathological results. Our results suggest that the additional use of RVS on second-look sonography significantly increases the sonographic detection rate of MRI-detected lesions without operator dependence.
引用
收藏
页码:1179 / 1188
页数:9
相关论文
共 32 条
  • [21] Six-year prospective evaluation of second-look US with volume navigation for MRI-detected additional breast lesions
    Fausto, Alfonso
    Bernini, Marco
    La Forgia, Daniele
    Fanizzi, Annarita
    Marcasciano, Marco
    Volterrani, Luca
    Casella, Donato
    Mazzei, Maria Antonietta
    [J]. EUROPEAN RADIOLOGY, 2019, 29 (04) : 1799 - 1808
  • [22] Six-year prospective evaluation of second-look US with volume navigation for MRI-detected additional breast lesions
    Alfonso Fausto
    Marco Bernini
    Daniele La Forgia
    Annarita Fanizzi
    Marco Marcasciano
    Luca Volterrani
    Donato Casella
    Maria Antonietta Mazzei
    [J]. European Radiology, 2019, 29 : 1799 - 1808
  • [23] Evaluation of the intramammary distribution of breast lesions detected by MRI but not conventional second-look B-mode ultrasound using an MRI/ultrasound fusion technique
    Saito, Masayuki
    Banno, Hirona
    Ito, Yukie
    Ido, Mirai
    Goto, Manami
    Ando, Takahito
    Mouri, Yukako
    Kousaka, Junko
    Fujii, Kimihito
    Imai, Tsuneo
    Nakano, Shogo
    Suzuki, Kojiro
    [J]. BMC MEDICAL IMAGING, 2024, 24 (01):
  • [24] Targeted sonography using an image fusion technique for evaluation of incidentally detected breast lesions on chest CT: a pilot study
    Kousaka, Junko
    Nakano, Shogo
    Ando, Takahito
    Tetsuka, Rie
    Fujii, Kimihito
    Yoshida, Miwa
    Shiomi-Mouri, Yukako
    Goto, Manami
    Imai, Yuko
    Imai, Tsuneo
    Fukutomi, Takashi
    Katsuda, Eisuke
    Ishiguchi, Tsuneo
    Arai, Osamu
    [J]. BREAST CANCER, 2016, 23 (02) : 301 - 309
  • [25] Targeted sonography using an image fusion technique for evaluation of incidentally detected breast lesions on chest CT: a pilot study
    Junko Kousaka
    Shogo Nakano
    Takahito Ando
    Rie Tetsuka
    Kimihito Fujii
    Miwa Yoshida
    Yukako Shiomi-Mouri
    Manami Goto
    Yuko Imai
    Tsuneo Imai
    Takashi Fukutomi
    Eisuke Katsuda
    Tsuneo Ishiguchi
    Osamu Arai
    [J]. Breast Cancer, 2016, 23 : 301 - 309
  • [26] PRE-OPERATIVE PLANNING USING REAL-TIME VIRTUAL SONOGRAPHY, AN MRI/ULTRASOUND IMAGE FUSION TECHNIQUE, FOR BREAST-CONSERVING SURGERY IN PATIENTS WITH NON-MASS ENHANCEMENT ON BREAST MRI: A PRELIMINARY STUDY
    Ando, Takahito
    Ito, Yukie
    Ido, Mirai
    Osawa, Manami
    Kousaka, Junko
    Mouri, Yukako
    Fujii, Kimihito
    Nakano, Shogo
    Kimura, Junko
    Ishiguchi, Tsuneo
    Watanebe, Rie
    Imai, Tsuneo
    Fukutomi, Takashi
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (07): : 1364 - 1370
  • [27] PROSTATE-TARGETED BIOPSY UNDER REAL-TIME VIRTUAL SONOGRAPHY BASED ON MRI DATA: EVALUATION OF ACCURACY WITH RESECTED SPECIMENS
    Miyagawa, Tomoaki
    Ishikawa, Satoru
    Matsuoka, Taeko
    Kandori, Shuya
    Emura, Masahiro
    Suetomi, Takahiro
    Tsutsumi, Masakazu
    Irie, Toshiyuki
    Kondou, Masanao
    Mitake, Tsuyoshi
    [J]. JOURNAL OF UROLOGY, 2010, 183 (04): : E779 - E779
  • [28] Evaluation of an MRI/US fusion technique for the detection of non-mass enhancement of breast lesions detected by MRI yet occult on conventional B-mode second-look US
    Manami Goto
    Shogo Nakano
    Masayuki Saito
    Hirona Banno
    Yukie Ito
    Mirai Ido
    Takahito Ando
    Junko Kousaka
    Kimihito Fujii
    Kojiro Suzuki
    [J]. Journal of Medical Ultrasonics, 2022, 49 : 269 - 278
  • [29] Evaluation of an MRI/US fusion technique for the detection of non-mass enhancement of breast lesions detected by MRI yet occult on conventional B-mode second-look US
    Goto, Manami
    Nakano, Shogo
    Saito, Masayuki
    Banno, Hirona
    Ito, Yukie
    Ido, Mirai
    Ando, Takahito
    Kousaka, Junko
    Fujii, Kimihito
    Suzuki, Kojiro
    [J]. JOURNAL OF MEDICAL ULTRASONICS, 2022, 49 (02) : 269 - 278
  • [30] Real-time MRI navigated US: Role in diagnosis and guided biopsy of incidental breast lesions and axillary lymph nodes detected on breast MRI but not on second look US
    Pastor Pons, Elena
    Miras Azcon, Francisco
    Culianez Casas, Maria
    Martinez Meca, Salvador
    Garcia Espona, Jose Luis
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (06) : 942 - 950