Structural response of a cable-stayed bridge subjected to lateral seismic excitations

被引:0
|
作者
Amr Z. Elkady
Maryam A. Seleemah
Farhad Ansari
机构
[1] Tanta University,Faculty of Engineering
[2] University of Illinois,Visiting Researcher at the Department of Civil and Materials Engineering
[3] Tanta University,Department of Structural Engineering, Faculty of Engineering
[4] University of Illinois at Chicago,Christopher B. and Susan S. Burke Distinguished Professor, Department of Civil and Materials Engineering
关键词
Cable-stayed bridges; Earthquakes; Lateral excitations; Resonance; Fiber Bragg grating (FBG); Structural health monitoring;
D O I
暂无
中图分类号
学科分类号
摘要
Cable-stayed bridges are structurally efficient and offer cost effective solutions in medium to large-span crossings. The study reported in this article aimed at determining the behavior of a typical cable-stayed bridge when subjected to lateral earthquake excitations. A hybrid analytical–experimental technique is introduced to experimentally simulate the earthquake excitations on the bridge. In this technique, displacement time history of the bridge mid-span was first obtained analytically by exciting the bridge using the earthquake acceleration records. To experimentally simulate the earthquake excitations, these displacements were applied on a 160\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$ \frac{1}{60} $$\end{document} scale model of a single plane cable-stayed bridge using a displacement controlled shaker. The efficiency of this technique was evaluated by comparing the experimental versus analytical response in terms of dynamic characteristics and displacement responses of the bridge. The analytical response of the bridge served as a verification tool for validation of key response parameters of the full-scale bridge. These parameters included forces in cables, strains and stresses in the deck, and moments and shear forces acting on pylons in the transverse direction.
引用
收藏
页码:417 / 430
页数:13
相关论文
共 50 条
  • [21] Lateral vibration on a pedestrian cable-stayed bridge
    Nakamura, Shun-Ichi
    Fujino, Yozo
    [J]. Structural Engineering International: Journal of the International Association for Bridge and Structural Engineering (IABSE), 2002, 12 (04): : 295 - 300
  • [22] Non linear seismic response analysis of the Aratsu cable-stayed bridge
    Yamahira, K
    Otsuka, H
    Uno, K
    Doujou, Y
    Katou, I
    Fujino, A
    [J]. EARTHQUAKE RESISTANT ENGINEERING STRUCTURES II, 1999, : 175 - 186
  • [23] Influence of stabilizing cables on seismic response of a multispan cable-stayed bridge
    Ni, YQ
    Wang, JY
    Lo, LC
    [J]. COMPUTER-AIDED CIVIL AND INFRASTRUCTURE ENGINEERING, 2005, 20 (02) : 142 - 153
  • [24] Seismic Response Analysis of Multi-span Cable-stayed Bridge
    He, Guojing
    Zou, Zhongquan
    Ni, Yi-qing
    Ko, Jinming
    [J]. ADVANCES IN CONCRETE AND STRUCTURES, 2009, 400-402 : 737 - +
  • [25] The Seismic Response Analysis of Long-Span Cable-Stayed Bridge
    Niu, Yongzhe
    Guo, Wenjie
    Li, Guangling
    Sun, Ruixin
    [J]. ADVANCES IN CIVIL AND STRUCTURAL ENGINEERING III, PTS 1-4, 2014, 501-504 : 1364 - +
  • [26] Seismic response control of a benchmark cable-stayed bridge by variable dampers
    Ruangrassamee, A
    Kawashima, K
    [J]. PROCEEDINGS OF THE 2002 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 2002, 1-6 : 3064 - 3069
  • [27] Random Vibrations of a Cable-Stayed Bridge under Multi-Dimensional Seismic Excitations
    Sun, Zuoyu
    Wang, Hui
    Fang, Mingsheng
    Mao, Keyang
    [J]. MATERIALS PROCESSING AND MANUFACTURING III, PTS 1-4, 2013, 753-755 : 1119 - 1123
  • [28] Seismic response analysis to half floating system of cable-stayed bridge
    School of Transportation Science and Engineering, Harbin Institute of Technology, Harbin 150090, China
    不详
    [J]. Key Eng Mat, (81-90):
  • [29] MATLAB-based seismic response control of a cable-stayed bridge: cable vibration
    Loh, Chin-Hsiung
    Chang, Chia-Ming
    [J]. STRUCTURAL CONTROL & HEALTH MONITORING, 2007, 14 (01): : 109 - 143
  • [30] The cable-stayed bridge with the T - structure collaborative system bridge seismic response analysis
    Yu, Baochu
    Zhang, Dayong
    Gao, Shaoxiao
    Tang, Xiaocheng
    [J]. ADVANCES IN INDUSTRIAL AND CIVIL ENGINEERING, PTS 1-4, 2012, 594-597 : 1762 - 1765