A Dynamic Tonometer for Measuring Intraocular Pressure

被引:0
|
作者
Dikin V.I. [1 ]
Ivanyschev C.V. [2 ]
Kornev N.P. [2 ]
Mikheev A.A. [1 ]
Solomakha V.N. [2 ]
机构
[1] Ryazan State Radio Engineering University, Ryazan
[2] Elatma Instrument Manufacturing Plant, Elatma, Ryazan Region
关键词
Intraocular Pressure; Inductance Coil; Elastic Bond; Rigidity Coefficient; Spherical Envelope;
D O I
10.1007/s10527-013-9351-8
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The principle of action of a dynamic tonometer for measuring intraocular pressure is considered. It is based on monitoring of the oscillation period of the dynamic system of tonometer elements and the eye. A model of the tonometer-eye oscillation system is presented. The effect of eye elements (eyelid and cornea) on the oscillation period of the system is considered. An example of practical implementation of this system is given. © 2013 Springer Science+Business Media New York.
引用
收藏
页码:130 / 133
页数:3
相关论文
共 50 条
  • [1] Assessment of the Pascal dynamic contour tonometer in measuring intraocular pressure in keratoconic eyes
    Papavergiou, Georgios I.
    Kozobolis, Vasiliios
    Siganos, Dimitrios S.
    JOURNAL OF GLAUCOMA, 2008, 17 (06) : 484 - 488
  • [2] Evaluation of a rebound tonometer for measuring intraocular pressure in dogs and horses
    Knollinger, AM
    La Croix, NC
    Barrett, PM
    Miller, PE
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2005, 227 (02): : 244 - 248
  • [3] WHY IS THE SCHIOTZ TONOMETER NOT SUITABLE FOR MEASURING INTRAOCULAR-PRESSURE
    STEPANIK, J
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1980, 176 (01) : 61 - 66
  • [4] Measurement of Intraocular Pressure with a Dynamic Tonometer and Presentation of Measurement Results
    M. Yu. Danichenko
    A. A. Mikheev
    Biomedical Engineering, 2022, 55 : 342 - 345
  • [5] Measurement of Intraocular Pressure with a Dynamic Tonometer and Presentation of Measurement Results
    Danichenko, M. Yu
    Mikheev, A. A.
    BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2022, 55 (05): : 342 - 345
  • [6] Evaluation of the New Digital Goldmann Applanation Tonometer for Measuring Intraocular Pressure
    Sakaue, Yuta
    Ueda, Jun
    Seki, Masaaki
    Tanaka, Takayuki
    Togano, Tetsuya
    Yoshino, Takaiko
    Fukuchi, Takeo
    JOURNAL OF OPHTHALMOLOGY, 2014, 2014
  • [7] Comparison of a rebound and an applanation tonometer for measuring intraocular pressure in normal rabbits
    Pereira, Fabiana Quartiero
    Bercht, Bernardo Stefano
    Soares, Mirian Gomes
    Bittencourt da Mota, Mauricio Grillo
    Tadeu Pigatto, Joao Antonio
    VETERINARY OPHTHALMOLOGY, 2011, 14 (05) : 321 - 326
  • [8] Evaluation of Rebound Tonometer for Measuring Intraocular Pressure at Deviated Angle and Position
    Takenaka, Joji
    Mochizuki, Hideki
    Kunihara, Eriko
    Tanaka, Junko
    Kiuchi, Yoshiaki
    CURRENT EYE RESEARCH, 2011, 36 (05) : 422 - 428
  • [9] Assessment of IcareONE rebound tonometer for self-measuring intraocular pressure
    Parodi, Maurizio Battaglia
    Iacono, Pierluigi
    Campa, Claudio
    La Spina, Carlo
    Triolo, Giacinto
    Lattanzio, Rosangela
    Bandello, Francesco
    ACTA OPHTHALMOLOGICA, 2014, 92 (03) : E243 - E244
  • [10] Evaluation of a new transpalpebral tonometer for self-measuring intraocular pressure
    Kobashi, Hidenaga
    PLOS ONE, 2024, 19 (05):