Preparation of Monolithic Capillary Chromatographic Columns Using Supercritical Fluid as a Porogen Solvent

被引:0
|
作者
Michał Szumski
Bogusław Buszewski
机构
[1] Nicolaus Copernicus University,Faculty of Chemistry, Department of Environmental Chemistry and Bioanalytics
来源
Chromatographia | 2014年 / 77卷
关键词
Capillary liquid chromatography; Monolithic polymeric column; Porogen solvent; Supercritical carbon dioxide;
D O I
暂无
中图分类号
学科分类号
摘要
Monolithic polymeric beds were synthesized in fused silica capillaries using either trimethylolpropane trimethacrylate (TRIM) or a mixture of butyl methacrylate (BMA) with ethylene glycol dimethacrylate (EDMA) as monomers. Carbon dioxide at temperature and pressure conditions above its critical values was used as a porogen solvent. The purpose of using the supercritical carbon dioxide was to have the possibility of changing the solvation power (and thus the porosity of the resulting monolith) of the porogen by pressure and temperature changes instead of changing the porogen composition. The experiments were performed using a special setup consisting of a stainless steel high-pressure reactor to which the fused silica capillary was connected. The synthesized monoliths underwent liquid chromatographic evaluation. The polyTRIM capillary monoliths were characterized by different permeability, which depended on the pressure of the synthesis. BMA/EDMA columns were applied for separation of alkylbenzenes and a model mixture of proteins.
引用
收藏
页码:1009 / 1017
页数:8
相关论文
共 50 条
  • [31] SPLITTING CONTROL AND SOLVENT EFFECTS IN SUPERCRITICAL-FLUID CHROMATOGRAPHY WITH FUSED-SILICA CAPILLARY COLUMNS
    BOHM, M
    UMLAND, F
    WENCLAWIAK, B
    JOURNAL OF CHROMATOGRAPHY, 1989, 465 (01): : 17 - 21
  • [32] Preparation and Evaluation of Monolithic Silica Columns for Capillary Electro chromatography
    Shao Hua
    Deng Qiliang
    Lun Zhihong
    Yan Chao
    Gao Ruyu
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2005, 23 (03) : 243 - 246
  • [33] Preparation and testing of methacrylate monolithic columns in capillary liquid chromatography
    Coufal, P
    Cihák, M
    Suchánková, J
    Tesarová, E
    CHEMICKE LISTY, 2001, 95 (08): : 509 - 512
  • [34] SUPERCRITICAL FLUID CHROMATOGRAPHY IN OPEN-TUBULAR CAPILLARY COLUMNS
    GUTHRIE, EJ
    FREEMAN, RR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1985, 190 (SEP): : 47 - ANL
  • [35] MODIFIER EFFECTS ON PACKED AND CAPILLARY COLUMNS IN SUPERCRITICAL FLUID CHROMATOGRAPHY
    SCHMIDT, S
    BLOMBERG, LG
    CAMPBELL, ER
    CHROMATOGRAPHIA, 1988, 25 (09) : 775 - 780
  • [36] SUPERCRITICAL FLUID CHROMATOGRAPHY WITH CAPILLARY AND PACKED-COLUMNS - (A REVIEW)
    WENCLAWIAK, B
    OHIO JOURNAL OF SCIENCE, 1986, 86 (02) : 22 - 22
  • [37] Effect of the nature of the carrier gas on the chromatographic characteristics of monolithic silica capillary columns
    Korolev, A. A.
    Shiryaeva, V. E.
    Popova, T. P.
    Kurganov, A. A.
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY, 2006, 80 (07): : 1135 - 1140
  • [38] High-performance liquid chromatographic enantioseparations on capillary columns containing monolithic
    Chankvetadze, B
    Yamamoto, C
    Tanaka, N
    Nakanishi, K
    Okamoto, Y
    JOURNAL OF SEPARATION SCIENCE, 2004, 27 (10-11) : 905 - 911
  • [39] Effect of the nature of the carrier gas on the chromatographic characteristics of monolithic silica capillary columns
    A. A. Korolev
    V. E. Shiryaeva
    T. P. Popova
    A. A. Kurganov
    Russian Journal of Physical Chemistry, 2006, 80 : 1135 - 1140
  • [40] RAPID CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHIC ANALYSIS OF CARBAMATE PESTICIDES
    WRIGHT, BW
    SMITH, RD
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1985, 8 (01): : 8 - 11