Lens opacity detection for serious posterior subcapsular cataract

被引:0
|
作者
Wanjun Zhang
Huiqi Li
机构
[1] Beijing Institute of Technology,School of Information and Electronics
关键词
Posterior subcapsular cataract; Markov random fields; Watershed; Mean gradient comparison;
D O I
暂无
中图分类号
学科分类号
摘要
Cataract leads to visual impairment. Among different types of cataract, posterior subcapsular cataract (PSC) can develop rapidly and surgery is usually needed. An approach to detect PSC opacities in retro-illumination images is proposed. Watershed and Markov random fields (MRF) method are employed to opacities in anterior retro-illumination images. It results in a mixture of PSC, cortical opacities and noise. Then, information in both anterior and posterior retro-illumination images is utilized. Two features are extracted to identify PSC: mean gradient comparison (MGC) between anterior and posterior retro-illumination images, and spatial location. This is the first time that comparison between anterior and posterior retro-illumination images is proposed and MGC is proposed as the feature of comparison in PSC detection. Experiments show that the sensitivity and specificity of PSC screening is 91.2 and 90.1 %, respectively, based on the 519 pairs of testing images. To the best of our knowledge, it is the best performance reported in automatic detection of PSC. Compared with the methods in the literatures, considerable improvement is achieved when there are large areas of PSC opacities.
引用
收藏
页码:769 / 779
页数:10
相关论文
共 50 条
  • [21] Phacoemulsification in posterior polar cataract: does size of lens opacity affect surgical outcome?
    Kumar, Sunil
    Ram, Jagat
    Sukhija, Jaspreet
    Severia, Saurabh
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 38 (09): : 857 - 861
  • [22] Vitamin D deficiency and posterior subcapsular cataract
    Brown, Craig J.
    Akaichi, Faical
    [J]. CLINICAL OPHTHALMOLOGY, 2015, 9 : 1093 - 1098
  • [23] Elevated level of uric acid in aqueous humour is associated with posterior subcapsular cataract in human lens
    Qin, Yong Jie
    Chan, Sun On
    Lin, Hong Liang
    Zhang, Yu Qiao
    Chen, Yan Lei
    Niu, Yong Yi
    Xie, Wen Juan
    Chu, Wai Kit
    Pang, Chi Pui
    Zhang, Hong Yang
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 48 (09): : 1183 - 1191
  • [24] Posterior subcapsular cataract and hip fracture - Response
    Ivers, RQ
    Cumming, RG
    Mitchell, P
    Simpson, JM
    [J]. JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2004, 52 (04) : 650 - 651
  • [25] VISION THROUGH NUCLEAR AND POSTERIOR SUBCAPSULAR CATARACT
    BARALDI, P
    ENOCH, JM
    RAPHAEL, S
    [J]. INTERNATIONAL OPHTHALMOLOGY, 1986, 9 (2-3) : 173 - 178
  • [26] Objective Quantification of Lens Opacity in Posterior Subcapsular Cataracts Using IOL Master 700 and CASIA-2
    Fan, Shuxin
    Feng, Rui
    Liang, Feiyan
    Li, Chuang
    Tao, Shuya
    Wang, Mingwei
    He, Chang
    Liu, Xialin
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 254 : 203 - 209
  • [27] Observation of anterior subcapsular lens opacity by scanning electron microscopy
    Kawai, K
    Sueno, T
    Saito, N
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U170 - U170
  • [28] Aberrant lens fiber migration in Royal College of Surgeons rats during posterior subcapsular cataract formation
    Al-Ghoul, KJ
    Mohammed, TA
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U981 - U981
  • [29] Posterior subcapsular cataract in association with fludrocortisone acetate therapy
    Whyte, Ian M.
    Prior, Felicity H.
    Emslie, Ian K.
    Davies, Peter E. J.
    Cosgrove, John
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 (08): : 799 - 800
  • [30] INDAPAMIDE THERAPY AND POSTERIOR SUBCAPSULAR CATARACT - IS THERE A CAUSAL RELATIONSHIP
    CACCAMISE, WC
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (03) : 298 - 299