Development of a vortex-assisted dispersive micro-solid-phase extraction using reduced graphene oxide/Fe3O4 nanocomposites for the determination of chlorfenson pesticide in green tea samples by high-performance liquid chromatography-ultraviolet detection

被引:0
|
作者
Nazlıgül Aydin
Zeynep Tekin
Nouha Bakaraki Turan
Sezgin Bakırdere
机构
[1] Yıldız Technical University,Faculty of Art and Science, Department of Chemistry
[2] Yıldız Technical University,Faculty of Civil Engineering, Department of Environmental Engineering
[3] Turkish Academy of Sciences (TÜBA),undefined
来源
Chemical Papers | 2023年 / 77卷
关键词
Chlorfenson; Dispersive micro-solid-phase extraction; Magnetite nanoparticles; Matrix matching; Green tea;
D O I
暂无
中图分类号
学科分类号
摘要
Pesticides are the group of chemicals used for the protection of plants against pests and other harmful organisms. The excessive and uncontrolled usage of pesticides may lead to the contamination of environment with pesticides posing a serious risk to human health and ecology. Based on this, the ability to detect and monitor the level of pesticides in different environmental compartments became a serious need. In this study, the reduced graphene oxide–magnetite nanocomposites (rGO-Fe3O4-NC)-based vortex-assisted dispersive micro-solid-phase extraction (VA-DMSPE) method was developed and optimized for the detection of chlorfenson pesticide by high-performance liquid chromatography-ultraviolet detection system. For this purpose, the synthesis of rGO-Fe3O4-NC was performed to be later applied as an adsorbent of the target analyte in the study. Furthermore, the extraction parameters such as the buffer pH, buffer amount, sorbent amount and eluent volume were optimized to obtain the highest detection efficiency of chlorfenson. The limit of detection (LOD) and limit of quantification (LOQ) were 0.02 and 0.07 μg L−1, respectively. The improvement in the detection power was found to be 33.5. The proposed method accuracy was tested in green tea samples where the percent recovery for two different types of green tea samples was in the range of 96–109%.
引用
收藏
页码:2141 / 2149
页数:8
相关论文
共 50 条
  • [11] Dispersive solid phase extraction followed by low-toxicity vortex-assisted liquid-liquid microextraction for the determination of organophosphorus pesticides by high-performance liquid chromatography
    Peng, Guilong
    He, Qiang
    Lu, Ying
    Mmereki, Daniel
    Zhong, Zhihui
    Jiang, Kaiyong
    Chen, Dingjun
    ANALYTICAL METHODS, 2016, 8 (12) : 2684 - 2690
  • [12] Superparamagnetic graphene oxide-based dispersive-solid phase extraction for preconcentration and determination of tamsulosin hydrochloride in human plasma by high performance liquid chromatography-ultraviolet detection
    Pashaei, Yaser
    Ghorbani-Bidkorbeh, Fatemeh
    Shekarchi, Maryam
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1499 : 21 - 29
  • [13] Application of dispersive liquid-liquid microextraction and dispersive micro-solid-phase extraction for the determination of quinolones in swine muscle by high-performance liquid chromatography with diode-array detection
    Tsai, Wen-Hsien
    Chuang, Hung-Yi
    Chen, Ho-Hsien
    Huang, Joh-Jong
    Chen, Hwi-Chang
    Cheng, Shou-Hsun
    Huang, Tzou-Chi
    ANALYTICA CHIMICA ACTA, 2009, 656 (1-2) : 56 - 62
  • [14] Determination of estrogens in environmental water samples with solid-phase extraction packed with bamboo charcoal prior to high-performance liquid chromatography-ultraviolet detection
    Zhou, Jia-Bin
    Hu, Cong
    Zhao, Ru-Song
    ANALYTICAL METHODS, 2011, 3 (11) : 2568 - 2572
  • [15] Polymethyldopamin@Fe3O4 for Magnetic Solid Phase Extraction of Polycyclic Aromatic Hydrocarbons Combined with DES as Desorption Solvent and High-Performance Liquid Chromatography-Ultraviolet Detection
    Ghani, Milad
    Maleki, Behrooz
    Jafari, Zahra
    Veisi, Hojat
    POLYCYCLIC AROMATIC COMPOUNDS, 2024, 44 (04) : 2381 - 2393
  • [16] Selective separation and determination of the synthetic colorants in beverages by magnetic solid-phase dispersion extraction based on a Fe3O4/reduced graphene oxide nanocomposite followed by high-performance liquid chromatography with diode array detection
    Wang, Xi
    Chen, Ning
    Han, Qing
    Yang, Zaiyue
    Wu, Jinhua
    Xue, Cheng
    Hong, Junli
    Zhou, Xuemin
    Jiang, Huijun
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (12) : 2167 - 2173
  • [17] Magnetic dispersive micro-solid-phase extraction using Fe3O4@AC-DZ nanosorbent for the determination of Cr(VI) in water samples
    Sadeghi, Susan
    Bijaem, Tahereh Mohammadi
    JOURNAL OF DISPERSION SCIENCE AND TECHNOLOGY, 2023, 44 (01) : 75 - 85
  • [18] Trace determination of chlorpheniramine in human plasma using magnetic dispersive solid-phase extraction based on a graphene oxide/Fe3O4@polythionine nanocomposite combined with high-performance liquid chromatography
    Daryakenary, Maryam Ahmadi
    Zeeb, Mohsen
    RSC ADVANCES, 2017, 7 (84) : 53210 - 53218
  • [19] Ultrasound-assisted magnetic dispersive micro-solid-phase extraction based on carbon quantum dots/zeolite imidazolate framework-90/polyvinyl pyrrolidone/Fe3O4 followed by high-performance liquid chromatography with ultraviolet detection for trace analysis of paracetamol and etodolac in human plasma
    Ahmadi, Kimia
    Abolfathi, Aysan
    Nasirimoghadam, Sana
    Kalkhoran, Negar Nasiri Moghaddam
    Zeeb, Mohsen
    RSC ADVANCES, 2024, 14 (45) : 33418 - 33428
  • [20] Determination of trace bisphenol A in environmental water by high-performance liquid chromatography using magnetic reduced graphene oxide based solid-phase extraction coupled with dispersive liquid–liquid microextraction
    Danping Li
    Xiaoguo Ma
    Rui Wang
    Yumian Yu
    Analytical and Bioanalytical Chemistry, 2017, 409 : 1165 - 1172