CT evaluation prior to transapical aortic valve replacement: semi-automatic versus manual image segmentation

被引:0
|
作者
Borek Foldyna
Camelia Jungert
Christian Luecke
Konstantin von Aspern
Sonja Boehmer-Lasthaus
Eva Maria Rueth
Matthias Grothoff
Stefan Nitzsche
Matthias Gutberlet
Friedrich Wilhelm Mohr
Lukas Lehmkuhl
机构
[1] University of Leipzig – Heart Center,Department of Interventional and Diagnostic Radiology
[2] University of Leipzig – Heart Center,Department of Cardiac Surgery
[3] Siemens Healthcare – Imaging & Therapy,undefined
关键词
Transapical valve replacement; Aortic valve; Computed tomography; Data segmentation; Data evaluation; Experienced versus inexperienced users; Efficiency;
D O I
暂无
中图分类号
学科分类号
摘要
To compare the performance of semi-automatic versus manual segmentation for ECG-triggered cardiovascular computed tomography (CT) examinations prior to transcatheter aortic valve replacement (TAVR), with focus on the speed and precision of experienced versus inexperienced observers. The preoperative ECG-triggered CT data of 30 consecutive patients who were scheduled for TAVR were included. All datasets were separately evaluated by two radiologists with 1 and 5 years of experience (novice and expert, respectively) in cardiovascular CT using an evaluation software program with or without a semi-automatic TAVR workflow. The time expended for data loading and all segmentation steps required for the implantation planning were assessed. Inter-software as well as inter-observer reliability analysis was performed. The CT datasets were successfully evaluated, with mean duration between 520.4 ± 117.6 s and 693.2 ± 159.5 s. The three most time-consuming steps were the 3D volume rendering, the measurement of aorta diameter and the sizing of the aortic annulus. Using semi-automatic segmentation, a novice could evaluate CT data approximately 12.3 % faster than with manual segmentation, and an expert could evaluate CT data approximately 10.3 % faster [mean differences of 85.4 ± 83.8 s (p < 0.001) and 59.8 ± 101 s (p < 0.001), respectively]. The inter-software reliability for a novice was slightly lower than for an expert; however, the reliability for a novice and expert was excellent (ICC 0.92, 95 % CI 0.75–0.97/ICC 0.96, 95 % CI 0.91–0.98). Automatic aortic annulus detection failed in two patients (6.7 %). The study revealed excellent inter-software and inter-observer reliability, with a mean ICC of 0.95. TAVR evaluation can be accomplished significantly faster with semi-automatic rather than with manual segmentation, with comparable exactness, showing a benefit for experienced and inexperienced observers.
引用
收藏
页码:1233 / 1242
页数:9
相关论文
共 50 条
  • [1] CT evaluation prior to transapical aortic valve replacement: semi-automatic versus manual image segmentation
    Foldyna, Borek
    Jungert, Camelia
    Luecke, Christian
    von Aspern, Konstantin
    Boehmer-Lasthaus, Sonja
    Rueth, Eva Maria
    Grothoff, Matthias
    Nitzsche, Stefan
    Gutberlet, Matthias
    Mohr, Friedrich Wilhelm
    Lehmkuhl, Lukas
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (06): : 1233 - 1242
  • [2] Aortic root evaluation prior to transcatheter aortic valve implantation-Correlation of manual and semi-automatic measurements
    Horehledova, Barbora
    Mihl, Casper
    Schwemmer, Chris
    Hendriks, Babs M. F.
    Eijsvoogel, Nienke G.
    Kietselaer, Bastiaan L. J. H.
    Wildberger, Joachim E.
    Das, Marco
    PLOS ONE, 2018, 13 (06):
  • [3] Semi-automatic CT-angiography based evaluation of the aortic annulus in patients prior to TAVR: interchangeability with manual measurements
    Zinsser, Dominik
    Baumann, Alena B.
    Winter, Katharina Stella
    Bamberg, Fabian
    Lange, Philipp
    Nikolaou, Konstantin
    Reiser, Maximilian
    Kupatt, Christian
    Kroencke, Thomas
    Schwarz, Florian
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2018, 34 (10): : 1657 - 1667
  • [4] Semi-automatic CT-angiography based evaluation of the aortic annulus in patients prior to TAVR: interchangeability with manual measurements
    Dominik Zinsser
    Alena B Baumann
    Katharina Stella Winter
    Fabian Bamberg
    Philipp Lange
    Konstantin Nikolaou
    Maximilian Reiser
    Christian Kupatt
    Thomas Kröncke
    Florian Schwarz
    The International Journal of Cardiovascular Imaging, 2018, 34 : 1657 - 1667
  • [5] An improved image graph for semi-automatic segmentation
    Freedman, Daniel
    SIGNAL IMAGE AND VIDEO PROCESSING, 2012, 6 (04) : 533 - 545
  • [6] An improved image graph for semi-automatic segmentation
    Daniel Freedman
    Signal, Image and Video Processing, 2012, 6 : 533 - 545
  • [7] A semi-automatic method for vascular image segmentation
    School of Biology, Hunan University, Changsha, China
    不详
    Proc. - Int. Conf. Image Graph., ICIG, (3-7):
  • [8] Commentary: Transapical aortic valve replacement versus surgical aortic valve replacement: A fundamental touchstone! Comment
    Kuhn, Elmar W.
    Liakopoulos, Oliver J.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2021, 162 (06): : 1710 - 1711
  • [9] An evaluation of manual and semi-automatic laughter annotation
    Ludusan, Bogdan
    Wagner, Petra
    INTERSPEECH 2020, 2020, : 621 - 625
  • [10] REPLACEMENT OF MANUAL GMAW WELDING BY FCAW SEMI-AUTOMATIC WELDING
    Sigmund, Marian
    Cicha, Tadeas