Numerical investigation on the performance, sustainability, and efficiency of the deep borehole heat exchanger system for building heating

被引:0
|
作者
Chaofan Chen
Haibing Shao
Dmitri Naumov
Yanlong Kong
Kun Tu
Olaf Kolditz
机构
[1] Helmholtz Centre for Environmental Research (UFZ),Applied Environmental Systems Analysis
[2] Dresden University of Technology,Institute of Geology and Geophysics
[3] Freiberg University of Mining and Technology,Department of Environmental Sciences
[4] Chinese Academy of Sciences,undefined
[5] China University of Mining and Technology (Beijing),undefined
[6] University of California,undefined
来源
关键词
Deep borehole heat exchanger system; Performance; Sustainability; Temperature recovery ratio; Coefficient of system performance (CSP);
D O I
暂无
中图分类号
学科分类号
摘要
In densely inhabited urban areas, deep borehole heat exchangers (DBHE) have been proposed to be integrated with the heat pump in order to utilize geothermal energy for building heating purposes. In this work, a comprehensive numerical model was constructed with the OpenGeoSys (OGS) software applying the dual-continuum approach. The model was verified against analytical solution, as well as by comparing with the integrated heat flux distribution. A series of modeling scenarios were designed and simulated in this study to perform the DBHE system analysis and to investigate the influence of pipe materials, grout thermal conductivity, geothermal gradient, soil thermal conductivity, and groundwater flow. It was found that the soil thermal conductivity is the most important parameter for the DBHE system performance. Both thermally enhanced grout and the thermally insulated inner pipe will elevate the outflow temperature of the DBHE. With an elevated geothermal gradient of 0.04 °C m−1, the short-term sustainable specific heat extraction rate imposed on the DBHE can be increased to 150–200 W m−1. The quantification of maximum heat extraction rate was conducted based on the modeling of 30-year-long operation scenarios. With a standard geothermal gradient of 0.03 °C m−1, the extraction rate has to be kept below 125 W m−1 in the long-term operation. To reflect the electricity consumption by circulating pump, the coefficient of system performance (CSP) was proposed in this work to better quantify the system efficiency. With the typical pipe structure and flow rate specified in this study, it is found that the lower limit of the DBHE system is at a CSP value of 3.7. The extended numerical model presented in this study can be applied to the design and optimization of DBHE-coupled ground source heat pump systems.
引用
下载
收藏
相关论文
共 50 条
  • [21] Operation optimization of the coaxial deep borehole heat exchanger coupled with ground source heat pump for building heating
    Wang, Yaran
    Wang, Yeming
    You, Shijun
    Zheng, Xuejing
    Wei, Shen
    APPLIED THERMAL ENGINEERING, 2022, 213
  • [22] Numerical study on the heat performance of enhanced coaxial borehole heat exchanger and double U borehole heat exchanger
    Chen, Ke
    Zheng, Jia
    Li, Juan
    Shao, Jingli
    Zhang, Qiulan
    APPLIED THERMAL ENGINEERING, 2022, 203
  • [23] Numerical investigation on the influence of groundwater flow on long-term heat extraction performance of deep borehole heat exchanger array
    Yang, Xiong
    Cai, Wanlong
    Li, Yongpeng
    Wang, Ming
    Kong, Yanlong
    Wang, Fenghao
    Chen, Chaofan
    Geothermal Energy, 2024, 12 (01)
  • [24] Design optimization of medium-deep borehole heat exchanger for building heating under climate change
    Zhang, Sheng
    Liu, Jun
    Wang, Fenghao
    Chai, Jiale
    ENERGY, 2023, 282
  • [25] Effects of climate change on long-term building heating performance of medium-deep borehole heat exchanger coupled heat pump
    Zhang, Sheng
    Liu, Jun
    Zhang, Xia
    Niu, Dun
    Wang, Fenghao
    Chai, Jiale
    Lu, Yalin
    Sun, Yongjun
    Lin, Zhang
    ENERGY AND BUILDINGS, 2023, 293
  • [26] Experimental and numerical investigation of heat transfer performance and sustainability of deep borehole heat exchangers coupled with ground source heat pump systems
    Cai, Wanlong
    Wang, Fenghao
    Liu, Jun
    Wang, Zhihua
    Ma, Zhenjun
    APPLIED THERMAL ENGINEERING, 2019, 149 : 975 - 986
  • [27] Long-term Performance Evaluation and Economic Analysis for Deep Borehole Heat Exchanger Heating System in Weihe Basin
    Cai, Wanlong
    Wang, Fenghao
    Jiang, Jinghua
    Wang, Zeyuan
    Liu, Jun
    Chen, Chaofan
    FRONTIERS IN EARTH SCIENCE, 2022, 10
  • [28] Numerical investigation on the effects of geological parameters and layered subsurface on the thermal performance of medium-deep borehole heat exchanger
    Liu, Jun
    Wang, Fenghao
    Cai, Wanlong
    Wang, Zhihua
    Li, Chun
    RENEWABLE ENERGY, 2020, 149 : 384 - 399
  • [29] Numerical study on the effects of design parameters on the heat transfer performance of coaxial deep borehole heat exchanger
    Liu, Jun
    Wang, Fenghao
    Cai, Wanlong
    Wang, Zhihua
    Wei, Qingpeng
    Deng, Jiewen
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (12) : 6337 - 6352
  • [30] Research on heat transfer performance and stability of deep borehole heat exchanger
    Cai, Wanlong
    Liu, Jun
    Wang, Fenghao
    Wang, Zhihua
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2020, 41 (02): : 158 - 164