Entanglement and Phase-Sensitivity of a Mach-Zehnder Interferometer for the Coherent Spin State Input

被引:0
|
作者
Xiao-jie Yi
机构
[1] Jiangxi Science and Technology Normal University,College of Communication and Electron
关键词
Quantum entanglement; Phase-sensitivity; Mach-Zehnder interferometer; Phase shift;
D O I
暂无
中图分类号
学科分类号
摘要
We study quantum entanglement and phase-sensitivity of a Mach-Zehnder interferometer for the coherent spin state input. It’s shown that entanglement and the Heisenberg limit of phase-sensitivity can be obtained adjusting the phase shift and increasing the total photons’ number.
引用
收藏
页码:1116 / 1120
页数:4
相关论文
共 50 条
  • [21] Phase sensitivity of a Mach-Zehnder interferometer -: art. no. 011801
    Pezzé, L
    Smerzi, A
    PHYSICAL REVIEW A, 2006, 73 (01):
  • [22] Ameliorated phase sensitivity through intensity measurements in a Mach-Zehnder interferometer
    Ramakrishnan, Jayanth
    Ivan, J. Solomon
    QUANTUM INFORMATION PROCESSING, 2022, 21 (01)
  • [23] Improvement in phase-sensitivity of a Mach–Zehnder interferometer with the superposition of Schrödinger’s cat-like state with vacuum state as an input under parity measurement
    Gaurav Shukla
    Krishna Mohan Mishra
    Aviral Kumar Pandey
    Taj Kumar
    Hemendra Pandey
    Devendra Kumar Mishra
    Optical and Quantum Electronics, 2023, 55 (5)
  • [24] Gaussian spatial -polarization entanglement in a folded Mach-Zehnder interferometer
    Asokan, S.
    Ivan, J. Solomon
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2020, 37 (05) : 825 - 832
  • [25] Enhancing Phase Sensitivity in Mach-Zehnder Interferometers for Arbitrary Input States
    Liang, Hongbin
    Pei, Jiancheng
    Wang, Xiaoguang
    CHINESE PHYSICS LETTERS, 2020, 37 (07)
  • [26] Sensitivity of Mach-Zehnder interferometer for dissolved gas monitoring
    Lindecrantz, Susan Mariah
    Dullo, Firehun Tsige
    Ahluwalia, Balpreet Singh
    Helleso, Olav Gaute
    INTEGRATED OPTICS: DEVICES, MATERIALS, AND TECHNOLOGIES XVIII, 2014, 8988
  • [27] Mach-Zehnder interferometer and the teleporter
    Ralph, TC
    PHYSICAL REVIEW A, 2000, 61 (04): : 4 - 443014
  • [28] MACH-ZEHNDER HETERODYNE INTERFEROMETER
    LAVAN, MJ
    VANDAMME, GE
    CADWALLENDER, WK
    OPTICAL ENGINEERING, 1976, 15 (05) : 464 - 466
  • [29] ASTIGMATISM IN MACH-ZEHNDER INTERFEROMETER
    PROWSE, DB
    APPLIED OPTICS, 1967, 6 (04): : 773 - &
  • [30] ASTIGMATISM IN MACH-ZEHNDER INTERFEROMETER
    TANNER, LH
    HOWES, WL
    BUCHELE, DR
    PROWSE, DB
    APPLIED OPTICS, 1967, 6 (09): : 1583 - &