Flow injection analysis of trace chromium (VI) in drinking water with a liquid waveguide capillary cell and spectrophotometric detection

被引:0
|
作者
Jian Ma
Dongxing Yuan
Robert H. Byrne
机构
[1] Xiamen University,State Key Laboratory of Marine Environmental Science, College of Environment and Ecology
[2] University of South Florida,College of Marine Science
来源
关键词
Liquid waveguide capillary cell; Flow injection analysis; Nanomolar detection limit; Chromium (VI); Drinking water; Spectrophotometry;
D O I
暂无
中图分类号
学科分类号
摘要
Hexavalent chromium (Cr(VI)) is an acknowledged hazardous material in drinking waters. As such, effective monitoring and assessment of the risks posed by Cr(VI) are important analytical objectives for both human health and environmental science. However, because of the lack of highly sensitive, rapid, and simple procedures, a relatively limited number of studies have been carried out in this field. Here we report a simple and sensitive analytical procedure of flow injection analysis (FIA) for sub-nanomolar Cr(VI) in drinking water samples with a liquid core waveguide capillary cell (LWCC). The procedure is based on a highly selective reaction between 1, 5-diphenylcarbazide and Cr(VI) under acidic conditions. The optimized experimental parameters included reagent concentrations, injection volume, length of mixing coil, and flow rate. Measurements at 540 nm, and a 650-nm reference wavelength, produced a 0.12-nM detection limit. Relative standard deviations for 1, 2, and 10 nM samples were 5.6, 3.6, and 0.72 % (n = 9), and the analysis time was <2 min sample−1. The effects of salinity and interfering ions, especially Fe(III), were evaluated. Using the FIA-LWCC method, different sources of bottled waters and tap waters were examined. The Cr(VI) concentrations of the bottled waters ranged from the detection limit to ∼20 nM, and tap waters collected from the same community supply had Cr(VI) concentration around 14 nM.
引用
收藏
页码:367 / 373
页数:6
相关论文
共 50 条
  • [1] Flow injection analysis of trace chromium (VI) in drinking water with a liquid waveguide capillary cell and spectrophotometric detection
    Ma, Jian
    Yuan, Dongxing
    Byrne, Robert H.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2014, 186 (01) : 367 - 373
  • [2] Enhanced sensitivity in flow injection analysis using a long pathlength liquid waveguide capillary flow cell for spectrophotometric detection
    Zhang, JZ
    ANALYTICAL SCIENCES, 2006, 22 (01) : 57 - 60
  • [3] Enhanced Sensitivity in Flow Injection Analysis Using a Long Pathlength Liquid Waveguide Capillary Flow Cell for Spectrophotometric Detection
    Jia-Zhong Zhang
    Analytical Sciences, 2006, 22 : 57 - 60
  • [4] Automated determination of uranium(VI) at ultra trace levels exploiting flow techniques and spectrophotometric detection using a liquid waveguide capillary cell
    Avivar, Jessica
    Ferrer, Laura
    Casas, Montserrat
    Cerda, Victor
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (02) : 871 - 878
  • [5] Automated determination of uranium(VI) at ultra trace levels exploiting flow techniques and spectrophotometric detection using a liquid waveguide capillary cell
    Jessica Avivar
    Laura Ferrer
    Montserrat Casas
    Víctor Cerdà
    Analytical and Bioanalytical Chemistry, 2010, 397 : 871 - 878
  • [6] Flow-Injection Spectrophotometric Determination of Bromate in Bottled Drinking Water Samples Using Chlorpromazine Reagent and a Liquid Waveguide Capillary Cell
    Toth, Ildiko V.
    Santos, Ines C.
    Azevedo, Claudia F. M.
    Fernandes, Jorge E. S.
    Pascoa, Ricardo N. M. J.
    Mesquita, Raquel B. R.
    Rangel, Antonio O. S. S.
    ANALYTICAL SCIENCES, 2013, 29 (05) : 563 - 570
  • [7] Flow-injection spectrophotometric determination of bromate in bottled drinking water samples using chlorpromazine reagent and a liquid waveguide capillary cell
    Tóth I.
    Santos I.
    Azevedo C.
    Fernandes J.
    Rangel A.O.S.S.
    Páscoa R.
    Mesquita R.
    Analytical Sciences, 2013, 29 (5) : 563 - 570
  • [8] Rapid speciation of trace iron in rainwater by reverse flow injection analysis coupled to a long path length liquid waveguide capillary cell and spectrophotometric detection
    Huang, Yongming
    Yuan, Dongxing
    Ma, Jian
    Zhang, Min
    Chen, Guohe
    MICROCHIMICA ACTA, 2009, 166 (3-4) : 221 - 228
  • [9] Rapid speciation of trace iron in rainwater by reverse flow injection analysis coupled to a long path length liquid waveguide capillary cell and spectrophotometric detection
    Yongming Huang
    Dongxing Yuan
    Jian Ma
    Min Zhang
    Guohe Chen
    Microchimica Acta, 2009, 166 : 221 - 228
  • [10] Direct spectrophotometric analysis of Cr(VI) using a liquid waveguide capillary cell
    Levitskaia, Tatiana G.
    O'Hara, Matthew J.
    Sinkov, Sergei I.
    Egorov, Oleg B.
    APPLIED SPECTROSCOPY, 2008, 62 (01) : 107 - 115