Scanning SQUID microscope system for geological samples: system integration and initial evaluation

被引:0
|
作者
Hirokuni Oda
Jun Kawai
Masakazu Miyamoto
Isoji Miyagi
Masahiko Sato
Atsushi Noguchi
Yuhji Yamamoto
Jun-ichi Fujihira
Nobuyoshi Natsuhara
Yoshiyasu Aramaki
Takashige Masuda
Chuang Xuan
机构
[1] AIST,Research Institute of Geology and Geoinformation, Geological Survey of Japan
[2] Kanazawa Institute of Technology,Applied Electronics Laboratory
[3] AIST,Research Institute of Earthquake and Volcano Geology, Geological Survey of Japan
[4] Kochi University,Center for Advanced Marine Core Research
[5] Fujihira Co. Ltd.,School of Ocean and Earth Science, National Oceanography Centre Southampton
[6] Natsuhara Giken Co. Ltd.,undefined
[7] Ayzy Co. Ltd.,undefined
[8] Ohtama Co.,undefined
[9] Ltd.,undefined
[10] University of Southampton,undefined
来源
关键词
SQUID sensor; Magnetic microscopy; Magnetic shield; Point source; stage; Sensitivity; Noise; Detection limit; Drift; Paleomagnetism; Magnetostratigraphy;
D O I
暂无
中图分类号
学科分类号
摘要
We have developed a high-resolution scanning superconducting quantum interference device (SQUID) microscope for imaging the magnetic field of geological samples at room temperature. In this paper, we provide details about the scanning SQUID microscope system, including the magnetically shielded box (MSB), the XYZ stage, data acquisition by the system, and initial evaluation of the system. The background noise in a two-layered PC permalloy MSB is approximately 40–50 pT. The long-term drift of the system is approximately ≥1 nT, which can be reduced by drift correction for each measurement line. The stroke of the XYZ stage is 100 mm × 100 mm with an accuracy of ~10 µm, which was confirmed by laser interferometry. A SQUID chip has a pick-up area of 200 μm × 200 μm with an inner hole of 30 μm × 30 μm. The sensitivity is 722.6 nT/V. The flux-locked loop has four gains, i.e., ×1, ×10, ×100, and ×500. An analog-to-digital converter allows analog voltage input in the range of about ±7.5 V in 0.6-mV steps. The maximum dynamic range is approximately ±5400 nT, and the minimum digitizable magnetic field is ~0.9 pT. The sensor-to-sample distance is measured with a precision line current, which gives the minimum of ~200 µm. Considering the size of pick-up coil, sensor-to-sample distance, and the accuracy of XYZ stage, spacial resolution of the system is ~200 µm. We developed the software used to measure the sensor-to-sample distance with line scan data, and the software to acquire data and control the XYZ stage for scanning. We also demonstrate the registration of the magnetic image relative to the optical image by using a pair of point sources placed on the corners of a sample holder outside of a thin section placed in the middle of the sample holder. Considering the minimum noise estimate of the current system, the theoretical detection limit of a single magnetic dipole is ~1 × 10−14 Am2. The new instrument is a powerful tool that could be used in various applications in paleomagnetism such as ultrafine-scale magnetostratigraphy and single-crystal paleomagnetism.Graphical Abstract.[graphic not available: see fulltext]
引用
收藏
相关论文
共 50 条
  • [1] Scanning SQUID microscope system for geological samples: system integration and initial evaluation
    Oda, Hirokuni
    Kawai, Jun
    Miyamoto, Masakazu
    Miyagi, Isoji
    Sato, Masahiko
    Noguchi, Atsushi
    Yamamoto, Yuhji
    Fujihira, Jun-ichi
    Natsuhara, Nobuyoshi
    Aramaki, Yoshiyasu
    Masuda, Takashige
    Xuan, Chuang
    EARTH PLANETS AND SPACE, 2016, 68
  • [2] Development of scanning SQUID microscope system and its applications on geological samples: A case study on marine ferromanganese crust
    Oda, H.
    Kawai, J.
    Usui, A.
    Yamamoto, Y.
    Noguchi, A.
    Miyagi, I
    Miyamoto, M.
    Fujihira, J.
    Sato, M.
    32ND INTERNATIONAL SYMPOSIUM ON SUPERCONDUCTIVITY (ISS2019), 2020, 1590
  • [3] Scanning SQUID microscope with an in-situ magnetization/demagnetization field for geological samples
    Du, Junwei
    Liu, Xiaohong
    Qin, Huafeng
    Wei, Zhao
    Kong, Xiangyang
    Liu, Qingsong
    Song, Tao
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2018, 547 : 1 - 6
  • [4] Scanning SQUID microscope for samples at room temperature
    Univ of Giessen, Germany
    IEEE Trans Appl Supercond, 2 III (4111-4114):
  • [5] A scanning SQUID microscope for samples at room temperature
    Dechert, J
    Mueck, M
    Heiden, C
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) : 4111 - 4114
  • [6] Practical scanning SQUID system for nondestructive evaluation
    Isawa, K
    Takagi, S
    Tosaka, S
    Nakayama, S
    Ikeda, A
    Chinone, K
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2005, 15 (02) : 715 - 718
  • [7] Scanning SQUID Microscope NDT System Based on Eddy Current Testing
    Zhong, C. R.
    He, Y. S.
    Liang, J. W.
    Ma, L.
    Lin, D. H.
    JOURNAL OF SUPERCONDUCTIVITY AND NOVEL MAGNETISM, 2010, 23 (06) : 981 - 983
  • [8] Observation of trapped flux by Scanning SQUID Microscope with novel cooling system
    Nakayama, S
    Morooka, T
    Odawara, A
    Nagata, A
    Ikeda, M
    Chinone, K
    ADVANCES IN SUPERCONDUCTIVITY XII, 2000, : 1033 - 1035
  • [9] Scanning SQUID Microscope NDT System Based on Eddy Current Testing
    C. R. Zhong
    Y. S. He
    J. W. Liang
    L. Ma
    D. H. Lin
    Journal of Superconductivity and Novel Magnetism, 2010, 23 : 981 - 983
  • [10] Automation and system integration of scanning tomographic acoustic microscope
    Kent, S. Davis
    Hua, Lee
    Computerized Medical Imaging and Graphics, 21 (05): : 265 - 276