Validation protocol for whole-body dosimetry in an agricultural exposure study

被引:0
|
作者
Jiho Lee
Eunhye Kim
Yongho Shin
Jonghwa Lee
Junghak Lee
Wolfgang Maasfeld
Jeong-Han Kim
机构
[1] Seoul National University,Department of Agricultural Biotechnology, Research Institute of Agriculture and Life Sciences
[2] Bayer CropScience,undefined
来源
关键词
Exposure; IOM sampler; Kresoxim-methyl; Method validation; Pesticide; Whole-body dosimetry;
D O I
暂无
中图分类号
学科分类号
摘要
Agricultural workers exposed to pesticides can experience adverse health impacts depending on toxicity and exposure amount. Whole-body dosimetry (WBD) is the most reliable, practical, and realistic method for measuring exposure. Since validation of analytical and experimental methodologies is critical for quantitative determination of exposure, we conducted a validation procedure to design an essential protocol for WBD exposure studies. Using the fungicide kresoxim-methyl, matrix-matched standards were prepared with various matrices including outer cloth, inner cloth, washing solution for gloves and hands, gauze, and glass fiber filter (IOM sampler) to determine the instrumental limit of quantitation for high-performance liquid chromatography (HPLC) (2 ng) and liquid chromatography–tandem mass spectrometry (LC–MS/MS) (10 pg). Method limits of quantitation (MLOQ) were also set for HPLC (0.1 mg/L) and LC–MS/MS (0.005 mg/L). We observed good analysis repeatability (coefficient of variation < 6%), and the linearity of the calibration curves was reasonable (r2 > 0.998) in the range of 0.001–10 mg/L in various matrices. Recovery tests were carried out at three levels of concentration (MLOQ, 10 MLOQ, and 100 MLOQ) and resulted in good recoveries (72.7–105.6%). We did not observe breakthrough of the compound in tests of holding capacity for glass fiber pesticide filters. The procedures established in the present study are applicable as an essential, comprehensive protocol for exposure assessment studies using WBD.
引用
收藏
页码:125 / 130
页数:5
相关论文
共 50 条
  • [1] Validation protocol for whole-body dosimetry in an agricultural exposure study
    Lee, Jiho
    Kim, Eunhye
    Shin, Yongho
    Lee, Jonghwa
    Lee, Junghak
    Maasfeld, Wolfgang
    Kim, Jeong-Han
    [J]. APPLIED BIOLOGICAL CHEMISTRY, 2018, 61 (01) : 125 - 130
  • [2] EVALUATION OF EXPOSURE TO WHOLE-BODY VIBRATION BY DOSIMETRY
    MALCHAIRE, J
    LEVIE, F
    RENS, G
    [J]. ANNALS OF OCCUPATIONAL HYGIENE, 1982, 25 (04): : 373 - 380
  • [3] Dosimetry of a Reverberation Chamber for Whole-Body Exposure of Small Animals
    Chakarothai, Jerdvisanop
    Wang, Jianqing
    Fujiwara, Osamu
    Wake, Kanako
    Watanabe, Soichi
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2013, 61 (09) : 3435 - 3445
  • [4] Flexible Dosimeter Bands for Whole-Body Dosimetry
    Kim, T.
    Fahimian, B.
    Pratx, G.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3871 - 3871
  • [5] Risk of dermal and inhalation exposure to chlorantraniliprole assessed by using whole-body dosimetry in Korea
    Noh, Hyun H.
    Lee, Jae Y.
    Park, Hyo K.
    Lee, Jung W.
    Jo, Seung H.
    Kim, Jeong-Han
    Kwon, Hyeyoung
    Kyung, Kee S.
    [J]. PEST MANAGEMENT SCIENCE, 2019, 75 (04) : 1159 - 1165
  • [7] EANM Dosimetry Committee guidelines for bone marrow and whole-body dosimetry
    Hindorf, Cecilia
    Glatting, Gerhard
    Chiesa, Carlo
    Linden, Ola
    Flux, Glenn
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (06) : 1238 - 1250
  • [8] EANM Dosimetry Committee guidelines for bone marrow and whole-body dosimetry
    Cecilia Hindorf
    Gerhard Glatting
    Carlo Chiesa
    Ola Lindén
    Glenn Flux
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2010, 37 : 1238 - 1250
  • [9] HUMAN WHOLE-BODY EXPOSURE TO INFRASOUND
    SLARVE, RN
    JOHNSON, DL
    [J]. AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1975, 46 (04): : 428 - 431
  • [10] Sensitivity of Whole-Body Dosimetry to Channel Model Parameters
    Jawad, Ourouk
    Lautru, David
    Benlarbi-Delai, Aziz
    De Doncker, Philippe
    [J]. IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2015, 63 (08) : 3654 - 3661