Short-term effects of fully bioabsorbable PLLA coronary stents in a porcine model

被引:0
|
作者
Li Shen
Qibing Wang
Yizhe Wu
Xi Hu
Jian Xie
Junbo Ge
机构
[1] Fudan University,Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital
[2] Shandong Huaan Biotechnology Co.,undefined
[3] Ltd,undefined
来源
Polymer Bulletin | 2012年 / 68卷
关键词
Bioabsorbable; PLLA; Stent; Stenosis;
D O I
暂无
中图分类号
学科分类号
摘要
Although metallic stents are effective in preventing acute occlusion and reducing late restenosis after coronary angioplasty, many concerns still remain. In this report, short-term effects of fully bioabsorbable sirolimus-loaded poly-l-lactic acid (PLLA) stents (Xinsorb) were evaluated in a porcine coronary model. Commercially available PLLA-coated sirolimus-eluting stents (Excel) were used as controls. The purpose of this study was to assess technical feasibility, biocompatibility, and impact on coronary stenosis of fully bioabsorbable PLLA stents. Our preliminary experience suggested that Xinsorb stents have succeeded in preventing elastic recoil and suppressing neointimal formation for the first 90 days and only mildly delayed the endothelialisation process of the stented blood vessel. Coronary stenosis following Xinsorb and Excel stent implantations after 30 and 90 days was 18.6 ± 5.2% versus 21.4 ± 7.2% and 24.5 ± 4.7% versus 27.7 ± 5.6%, respectively (p > 0.05). Both Xinsorb and Excel stents required approximately 1–3 months for re-endothelialization of the inner wall of stented blood vessels. These data provided additional insights into the mechanism and efficacy of fully bioabsorbable PLLA stents in normal porcine coronary arteries while raising questions regarding the potential durability of this novel medical device. Long-term follow-up will be required to validate the long-term efficacy of fully bioabsorbable PLLA stents.
引用
收藏
页码:1171 / 1181
页数:10
相关论文
共 50 条
  • [41] SHORT-TERM AND LONG-TERM EFFECTS OF TRANSCATHETER ABLATION OF THE CORONARY SINUS BY RADIOFREQUENCY ENERGY
    HUANG, SKS
    GRAHAM, AR
    BHARATI, S
    LEE, MA
    GORMAN, G
    LEV, M
    CIRCULATION, 1988, 78 (02) : 416 - 427
  • [42] EFFECTS OF SHORT-TERM AND LONG-TERM LEFT-VENTRICULAR HYPERTROPHY ON CORONARY CIRCULATION
    MARCUS, ML
    MUELLER, TM
    EASTHAM, CL
    AMERICAN JOURNAL OF PHYSIOLOGY, 1981, 241 (03): : H358 - H362
  • [43] Short-Term Effects of Renal Transplantation on Coronary Artery Calcification: A Prospective Study
    Priyadarshini, Pratyusha
    Aggarwal, Sandeep
    Guleria, Sandeep
    Sharma, Sanjiv
    Gulati, Gurpreet Singh
    SAUDI JOURNAL OF KIDNEY DISEASES AND TRANSPLANTATION, 2015, 26 (03) : 536 - 543
  • [44] The combined effects of diabetes and coronary atherosclerosis on the short-term risk of vascular events
    Saely, CH
    Aczel, S
    Marte, T
    Langer, P
    Drexel, H
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2003, 23 (05) : A37 - A37
  • [45] Hemodynamic effects of short-term hyperoxia after coronary artery bypass grafting
    Hendrik J. F. Helmerhorst
    Rob B. P. de Wilde
    Dae Hyun Lee
    Meindert Palmen
    Jos R. C. Jansen
    David J. van Westerloo
    Evert de Jonge
    Annals of Intensive Care, 7
  • [46] Hemodynamic effects of short-term hyperoxia after coronary artery bypass grafting
    Helmerhorst, Hendrik J. F.
    de Wilde, Rob B. P.
    Lee, Dae Hyun
    Palmen, Meindert
    Jansen, Jos R. C.
    van Westerloo, David J.
    de Jonge, Evert
    ANNALS OF INTENSIVE CARE, 2017, 7
  • [47] Cytochalasin D coated coronary stents inhibit neointimal formation in a porcine coronary model
    Huang, YM
    Salu, K
    Liu, XS
    Li, SQ
    Wang, L
    Verbeken, E
    Bosmans, J
    De Scheerder, I
    CIRCULATION, 2002, 106 (19) : 355 - 356
  • [48] SHORT-TERM AND LONG-TERM COMPLICATIONS OF CORONARY ANGIOPLASTY
    LANGE, RA
    HILLIS, LD
    CHEST, 1989, 96 (01) : 151 - 157
  • [49] Methylprednisolone coated stents decrease neointimal hyperplasia in a porcine coronary model
    Huang, YM
    Wang, L
    Vermeire, I
    Verbeken, E
    Schacht, E
    De Scheerder, I
    CIRCULATION, 2001, 104 (17) : 665 - 665
  • [50] Methylprednisolone coated stents decrease neointimal hyperplasia in a porcine coronary model
    Haung, Y
    Qiang, B
    Wang, L
    Vermeire, I
    Schacht, E
    De Scheerder, I
    Verbeken, E
    EUROPEAN HEART JOURNAL, 2001, 22 : 483 - +