Selection of sampling points for saturation recovery based myocardial T1 mapping

被引:0
|
作者
Mehmet Akcakaya
Sebastian Weingartner
Warren J Manning
Reza Nezafat
机构
[1] Beth Israel Deaconess Medical Center,Medicine
[2] Harvard Medical School,Computer Assisted Clinical Medicine
[3] University Medical Center Mannheim,Radiology
[4] Heidelberg University,undefined
[5] Beth Israel Deaconess Medical Center,undefined
[6] Harvard Medical School,undefined
关键词
Sampling Point; Fisher Information Matrix; Point Selection; Phantom Imaging; Saturation Recovery;
D O I
10.1186/1532-429X-16-S1-W32
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [11] Joint Myocardial T1 and T2 Mapping Using a Combination of Saturation Recovery and T2-preparation
    Akcakaya, Mehmet
    Weingaertner, Sebastian
    Basha, Tamer A.
    Roujol, Sebastien
    Bellm, Steven
    Nezafat, Reza
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (03) : 888 - 896
  • [12] Fast myocardial T1 mapping using shortened inversion recovery based schemes
    Huang, Li
    Neji, Radhouene
    Nazir, Muhummad Sohaib
    Whitaker, John
    Reid, Fiona
    Bosio, Filippo
    Chiribiri, Amedeo
    Razavi, Reza
    Roujol, Sebastien
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (02) : 641 - 654
  • [13] Fat-water separated myocardial T1 mapping with IDEAL-T1 saturation recovery gradient echo imaging
    Joseph J Pagano
    Kelvin Chow
    Ray Yang
    Richard B Thompson
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [14] T1 and T2 mapping is myocardial biopsy without sampling errors
    Nagao, Michinobu
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2023, 379 : 143 - 143
  • [15] Myocardial T1 values in healthy volunteers measured with saturation method using adaptive recovery times for T1 mapping (SMART1Map) at 1.5 T and 3 T
    Shunsuke Matsumoto
    Shigeo Okuda
    Yoshitake Yamada
    Tatsuya Suzuki
    Akihiro Tanimoto
    Atsushi Nozaki
    Masahiro Jinzaki
    Heart and Vessels, 2019, 34 : 1889 - 1894
  • [16] Myocardial T1 values in healthy volunteers measured with saturation method using adaptive recovery times for T1 mapping (SMART1Map) at 1.5 T and 3 T
    Matsumoto, Shunsuke
    Okuda, Shigeo
    Yamada, Yoshitake
    Suzuki, Tatsuya
    Tanimoto, Akihiro
    Nozaki, Atsushi
    Jinzaki, Masahiro
    HEART AND VESSELS, 2019, 34 (11) : 1889 - 1894
  • [17] True T1 mapping with SMART1Map (saturation method using adaptive recovery times for cardiac T1 mapping): a comparison with MOLLI
    Glenn S Slavin
    Jeff A Stainsby
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [18] Myocardial T1 mapping at 3.0T using inversion recovery FLASH readout
    Jiaxin Shao
    Kim-Lien Nguyen
    Peng Hu
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [19] Overview of Myocardial T1 Mapping Applications
    Varga-Szemes A.
    Muscogiuri G.
    Schoepf U.J.
    De Cecco C.N.
    Wichmann J.L.
    Mangold S.
    Caruso D.
    Fuller S.R.
    Spottiswoode B.S.
    van der Geest R.J.
    Suranyi P.
    Current Radiology Reports, 3 (9)
  • [20] Myocardial T1 Mapping - Hope or Hype?
    Bulluck, Heerajnarain
    Maestrini, Viviana
    Rosmini, Stefania
    Abdel-Gadir, Amna
    Treibel, Thomas A.
    Castelletti, Silvia
    Bucciarelli-Ducci, Chiara
    Manisty, Charlotte
    Moon, James C.
    CIRCULATION JOURNAL, 2015, 79 (03) : 487 - 494