A Bayesian Approach for Quantifying Trace Amounts of Antibody Aggregates by Sedimentation Velocity Analytical Ultracentrifugation

被引:0
|
作者
Patrick H. Brown
Andrea Balbo
Peter Schuck
机构
[1] National Institutes of Health,Dynamics of Macromolecular Assembly Section, Laboratory of Bioengineering and Physical Science, National Institute of Biomedical Imaging and Bioengineering
来源
关键词
analytical ultracentrifugation; Bayesian analysis; hydrodynamic separation; sedimentation velocity; size-distribution; trace aggregates;
D O I
暂无
中图分类号
学科分类号
摘要
Sedimentation velocity analytical ultracentrifugation (SV-AUC) has become an important tool for the characterization of the purity of protein therapeutics. The work presented here addresses a need for methods orthogonal to size-exclusion chromatography for ensuring the reliable quantitation of immunogenic oligomers, for example, in antibody preparations. Currently the most commonly used approach for SV-AUC analysis is the diffusion-deconvoluted sedimentation coefficient distribution c(s) method, previously developed by us as a general purpose technique and implemented in the software SEDFIT. In both practical and theoretical studies, different groups have reported a sensitivity of c(s) for trace oligomeric fractions well below the 1% level. In the present work we present a variant of c(s) designed for the purpose of trace detection, with customized Bayesian regularization. The original c(s) method relies on maximum entropy regularization providing the most parsimonious distribution consistent with the data. In the present paper, we use computer simulations of an antibody system as example to demonstrate that the standard maximum entropy regularization, due to its design, leads to a theoretical lower limit for the detection of oligomeric traces and a consistent underestimate of the trace populations by ∼0.1% (dependent on the level of regularization). This can be overcome with a recently developed Bayesian extension of c(s) (Brown et al., Biomacromolecules, 8:2011–2024, 2007), utilizing the known regions of sedimentation coefficients for the monomer and oligomers of interest as prior expectation for the peak positions in the distribution. We show that this leads to more clearly identifiable and consistent peaks and lower theoretical limits of quantization by approximately an order of magnitude for some experimental conditions. Implications for the experimental design of SV-AUC and practical detection limits are discussed.
引用
收藏
相关论文
共 50 条
  • [21] Precision of protein aggregation measurements by sedimentation velocity analytical ultracentrifugation in biopharmaceutical applications
    Gabrielson, John P.
    Arthur, Kelly K.
    Stoner, Michael R.
    Winn, Bradley C.
    Kendrick, Brent S.
    Razinkov, Vladimir
    Svitel, Juraj
    Jiang, Yijia
    Voelker, Paul J.
    Fernandes, Cledwyn A.
    Ridgeway, Ron
    ANALYTICAL BIOCHEMISTRY, 2010, 396 (02) : 231 - 241
  • [22] Some Lessons Learned From a Comparison Between Sedimentation Velocity Analytical Ultracentrifugation and Size Exclusion Chromatography to Characterize and Quantify Protein Aggregates
    Gandhi, Aditya V.
    Pothecary, Mark R.
    Bain, David L.
    Carpenter, John F.
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2017, 106 (08) : 2178 - 2186
  • [23] On computational approaches for size-and-shape distributions from sedimentation velocity analytical ultracentrifugation
    Schuck, Peter
    EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 2010, 39 (08): : 1261 - 1275
  • [24] Quantitation of Enterovirus A71 Empty and Full Particles by Sedimentation Velocity Analytical Ultracentrifugation
    Yang, Anna
    Luo, Yun
    Yang, Jie
    Xie, Tingbo
    Wang, Wenhui
    Wan, Xin
    Wang, Kaiwen
    Pang, Deqin
    Yang, Dongsheng
    Dai, Hanyu
    Wu, Jie
    Meng, Shengli
    Guo, Jing
    Wang, Zejun
    Shen, Shuo
    VIRUSES-BASEL, 2024, 16 (04):
  • [25] On computational approaches for size-and-shape distributions from sedimentation velocity analytical ultracentrifugation
    Peter Schuck
    European Biophysics Journal, 2010, 39 : 1261 - 1275
  • [26] Sedimentation Velocity Analytical Ultracentrifugation of Oxidized Recombinant Full-Length Factor VIII
    Zakas, Philip M.
    Healey, John F.
    Smith, Ian W.
    Lillicrap, David
    Lollar, Pete
    FRONTIERS IN IMMUNOLOGY, 2020, 11
  • [27] Small Volume Analytical Ultracentrifugation of AAV Vectors Based on the Band Sedimentation Velocity Method
    Maruno, Takahiro
    Ishii, Kentaro
    Torisu, Tetsuo
    Uchiyama, Susumu
    MOLECULAR THERAPY, 2023, 31 (04) : 577 - 577
  • [28] Fluorescence Detected Sedimentation Velocity Analytical Ultracentrifugation for Investigating Affinity and Stoichiometry of Protein Interactions
    Zhao, Huaying
    Chaturvedi, Sumit
    Schuck, Peter
    BIOPHYSICAL JOURNAL, 2017, 112 (03) : 199A - 199A
  • [29] Sedimentation Velocity Analytical Ultracentrifugation Analysis of Marketed Rituximab Drug Product Size Distribution
    Sharadrao M. Patil
    John Nguyen
    David A. Keire
    Kang Chen
    Pharmaceutical Research, 2020, 37
  • [30] Sedimentation velocity analytical ultracentrifugation studies of the 14-3-3 protein complexes
    Petrvalska, O.
    Kosek, D.
    Smidova, A.
    Kylarova, S.
    Kalabova, D.
    Obsilova, V.
    Obsil, T.
    FEBS JOURNAL, 2017, 284 : 85 - 86