The role of distal myocardial protection devices during percutaneous coronary interventions

被引:4
|
作者
Gorog D.A. [1 ,2 ]
机构
[1] Imperial College, London
[2] East and North Hertfordshire NHS Trust, Queen Elizabeth II Hospital, Welwyn Garden City
关键词
Percutaneous Coronary Intervention; Acute Myocardial Infarction; Major Adverse Cardiac Event; Primary Percutaneous Coronary Intervention; Saphenous Vein Graft;
D O I
10.1007/s11936-007-0051-0
中图分类号
学科分类号
摘要
The success of intervention and clinical outcome is markedly reduced in patients who sustain distal embolization during percutaneous coronary intervention (PCI). Such embolization occurs in up to 15% of patients with acute myocardial infarction (AMI) undergoing PCI, and angiographic indicators of embolization are highly predictive of clinical and functional outcome. Saphenous vein graft (SVG) interventions carry a 20% risk of major adverse cardiac events (MACE), predominantly AMI, and significant risk of no-reflow. There are four types of embolic protection: distal occlusion/aspiration systems, filters, proximal occlusion/aspiration devices, and thrombectomy catheters. There seem to be no data to suggest that routine use of any embolic protection system is beneficial in patients with ST-elevation myocardial infarction (STEMI) undergoing PCI. The message from both the EMERALD and PROMISE trials is that embolic protection does not improve perfusion in the setting of AMI. Although pretreatment with thrombus aspiration before PCI improves angiographic reperfusion rates compared with standard PCI, enzymatic release and early clinical outcomes are not improved. Although the clinical implications of routine thrombus aspiration have yet to be established, selective use may be justified in patients with the highest thrombus burden. In addition, it should be considered in those with acute stent thrombosis and elective use of filter-based protection considered in very high risk vessel PCI (eg, last remaining conduit). There is no easy way to anticipate which SVG intervention will result in embolization. In SVG intervention, both balloon occlusion/aspiration and filter-based distal protection devices have significantly reduced the incidence of 30-day MACE, driven by AMI and should, I believe, be used routinely. Risk of complications is low with all the established devices. The profile and deliverability are continuing to improve with newer devices. Cost-effectiveness of selective use in high-risk graft cases has only recently been demonstrated. Copyright © 2007 by Current Medicine Group LLC.
引用
收藏
页码:52 / 59
页数:7
相关论文
共 50 条
  • [21] Use of FilterWire EX for distal embolic protection during complex percutaneous coronary interventions: Four case studies
    Kornowski, R
    Assali, A
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 58 (03) : 364 - 369
  • [22] Role of distal protection devices
    Roberts, Matthew
    [J]. NEPHROLOGY, 2010, 15 : S227 - S233
  • [23] Superiority of the distal protection device over abciximab in preserving myocardial perfusion during percutaneous coronary intervention for acute myocardial infarction
    Mak, KH
    Phay, C
    Kwok, V
    Wong, A
    Chan, C
    Koh, TH
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (6A): : 189L - 189L
  • [24] Effect of distal protection device on the microvascular integrity in acute myocardial infarction during primary percutaneous coronary intervention
    Yoon, Myeong-Ho
    Tahk, Seung-Jea
    Choi, So-Yeon
    Choi, Tae-Young
    Choi, Byoung-Joo
    Choi, Jung-Hyun
    Yoo, Sang-Yong
    Ahn, Sung-Gyun
    Zheng, Zhen-Guo
    Hwang, Gyo-Seung
    Shin, Joon-Han
    [J]. CIRCULATION JOURNAL, 2006, 70 (10) : 1284 - 1289
  • [25] Endovascular arterial interventions with distal protection devices
    Cura, M
    Rundback, J
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 131 - 131
  • [26] Comeback for glycoprotein IIb/IIIa inhibitors during percutaneous coronary interventions for saphenous vein bypass grafts:: may be for distal protection with filter-based devices?
    Niemelä, KO
    [J]. EUROPEAN HEART JOURNAL, 2006, 27 (08) : 891 - 892
  • [27] Distal protection devices during percutaneous coronary intervention are effective in reducing death or recurrent myocardial infarction in saphenous vein grafts but not in acute myocardial infarction: A meta-analysis
    Qayyum, R
    Khalid, MR
    Adomaityte, J
    Papadakos, SR
    Messineo, FC
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 251A - 252A
  • [28] Combined distal protection and IIb/IIIa inhibitors vs distal protection alone during primary percutaneous coronary intervention in acute myocardial infarction: A randomized trial
    Fabbiocchi, F
    Ravagnani, P
    Calligaris, G
    De Martini, S
    Montorsi, P
    Galli, S
    Trabattoni, D
    Lualdi, A
    Bartorelli, A
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (6A): : 12E - 12E
  • [29] Role of Intracoronary Thrombolytic Therapy During Percutaneous Coronary Interventions
    Agarwal, Sanjeev Kumar
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (16) : S292 - S294
  • [30] The distal protection during primary percutaneous coronary intervention alleviates the adverse effects of large thrombus burden on myocardial reperfusion
    Umeda, H
    Katoh, T
    Iwase, M
    Izawa, H
    Nagata, K
    Watanabe, K
    Okada, T
    Yamada, T
    Tani, T
    Matsushita, T
    Murakami, Y
    Okamoto, M
    Shimizu, T
    Murohara, T
    Yokota, M
    [J]. CIRCULATION JOURNAL, 2006, 70 (03) : 232 - 238