Using a standalone ear-EEG device for focal-onset seizure detection

被引:4
|
作者
Joyner M. [1 ]
Hsu S.-H. [1 ]
Martin S. [1 ]
Dwyer J. [1 ]
Chen D.F. [2 ]
Sameni R. [5 ]
Waters S.H. [3 ]
Borodin K. [1 ]
Clifford G.D. [2 ,3 ]
Levey A.I. [2 ]
Hixson J. [4 ]
Winkel D. [2 ]
Berent J. [1 ]
机构
[1] NextSense Inc., Mountain View, CA
[2] Department of Neurology, Emory University School of Medicine, Atlanta, GA
[3] Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA
[4] Department of Neurology, University of California San Francisco, San Francisco, CA
[5] Department of Biomedical Informatics, Emory University School of Medicine, Atlanta, GA
关键词
Ear-EEG; Focal epilepsy; Long-term EEG; Seizure detection; Temporal lobe; Wearable technologies;
D O I
10.1186/s42234-023-00135-0
中图分类号
学科分类号
摘要
Background: Seizure detection is challenging outside the clinical environment due to the lack of comfortable, reliable, and practical long-term neurophysiological monitoring devices. We developed a novel, discreet, unobstructive in-ear sensing system that enables long-term electroencephalography (EEG) recording. This is the first study we are aware of that systematically compares the seizure detection utility of in-ear EEG with that of simultaneously recorded intracranial EEG. In addition, we present a similar comparison between simultaneously recorded in-ear EEG and scalp EEG. Methods: In this foundational research, we conducted a clinical feasibility study and validated the ability of the ear-EEG system to capture focal-onset seizures against 1255 hrs of simultaneous ear-EEG data along with scalp or intracranial EEG in 20 patients with refractory focal epilepsy (11 with scalp EEG, 8 with intracranial EEG, and 1 with both). Results: In a blinded, independent review of the ear-EEG signals, two epileptologists were able to detect 86.4% of the seizures that were subsequently identified using the clinical gold standard EEG modalities, with a false detection rate of 0.1 per day, well below what has been reported for ambulatory monitoring. The few seizures not detected on the ear-EEG signals emanated from deep within the mesial temporal lobe or extra-temporally and remained very focal, without significant propagation. Following multiple sessions of recording for a median continuous wear time of 13 hrs, patients reported a high degree of tolerance for the device, with only minor adverse events reported by the scalp EEG cohort. Conclusions: These preliminary results demonstrate the potential of using ear-EEG to enable routine collection of complementary, prolonged, and remote neurophysiological evidence, which may permit real-time detection of paroxysmal events such as seizures and epileptiform discharges. This study suggests that the ear-EEG device may assist clinicians in making an epilepsy diagnosis, assessing treatment efficacy, and optimizing medication titration. © The Author(s) 2024.
引用
下载
收藏
相关论文
共 50 条
  • [41] Automatic Detection of the Seizure Onset Zone based on ictal EEG
    Gritsch, G.
    Hartmann, M. M.
    Perko, H.
    Fuerbass, F.
    Ossenblok, P.
    Kluge, T.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 3901 - 3904
  • [42] EEG-Based Seizure detection using linear graph convolution network with focal loss
    Zhao, Yanna
    Dong, Changxu
    Zhang, Gaobo
    Wang, Yaru
    Chen, Xin
    Jia, Weikuan
    Yuan, Qi
    Xu, Fangzhou
    Zheng, Yuanjie
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2021, 208
  • [43] An Auditory P300-based Brain-Computer Interface Using Ear-EEG
    Kaongoen, Netiwit
    Jo, Sungho
    2018 6TH INTERNATIONAL CONFERENCE ON BRAIN-COMPUTER INTERFACE (BCI), 2018, : 134 - 137
  • [44] A novel online BCI system using speech imagery and ear-EEG for home appliances control
    Kaongoen, Netiwit
    Choi, Jaehoon
    Jo, Sungho
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2022, 224
  • [45] Detection of tonic seizures using a multimodal wearable device with behind-the-ear EEG
    Proost, R.
    Macea, J.
    Lagae, L.
    Van Paesschen, W.
    Jansen, K.
    EPILEPSIA, 2023, 64 : 453 - 454
  • [46] Seizure Onset Localization in Focal Epilepsy using intracranial-EEG data and the Schrodinger Operator's Spectrum
    Sadoun, Maria Sara Nour
    Laleg-Kirati, Taous-Meriem
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [47] Speech-imagery-based brain-computer interface system using ear-EEG
    Kaongoen, Netiwit
    Choi, Jaehoon
    Jo, Sungho
    JOURNAL OF NEURAL ENGINEERING, 2021, 18 (01)
  • [48] DETECTION OF THE ONSET OF EPILEPTIC SEIZURE SIGNAL FROM SCALP EEG USING BLIND SIGNAL SEPARATION
    Moghavvemi, M.
    Mehrkanoon, S.
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2009, 21 (04): : 287 - 290
  • [49] Seizure detection using scalp-EEG
    Baumgartner, Christoph
    Koren, Johannes P.
    EPILEPSIA, 2018, 59 : 14 - 22
  • [50] Epileptic Seizure Detection using EEG Signals
    Khan, Irfan Mabood
    Khan, Mohd Maaz
    Farooq, Omar
    5TH INTERNATIONAL CONFERENCE ON COMPUTING AND INFORMATICS (ICCI 2022), 2022, : 111 - 117