Characterization of Particles in Protein Solutions: Reaching the Limits of Current Technologies

被引:0
|
作者
Barthélemy Demeule
Steven Messick
Steven J. Shire
Jun Liu
机构
[1] Late Stage Pharmaceutical and Processing Development,
[2] Genentech Inc.,undefined
[3] QC Network Operation Support,undefined
[4] Genentech Inc.,undefined
来源
The AAPS Journal | 2010年 / 12卷
关键词
biopharmaceuticals; protein; sub-visible particles;
D O I
暂无
中图分类号
学科分类号
摘要
Recent publications have emphasized the lack of characterization methods available for protein particles in a size range comprised between 0.1 and 10 μm and the potential risk of immunogenicity associated with such particles. In the present paper, we have investigated the performance of light obscuration, flow microscopy, and Coulter counter instruments for particle counting and sizing in protein formulations. We focused on particles 2–10 μm in diameter and studied the effect of silicon oil droplets originating from the barrel of pre-filled syringes, as well as the effect of high protein concentrations (up to 150 mg/ml) on the accuracy of particle characterization. Silicon oil was demonstrated to contribute significantly to the particle counts observed in pre-filled syringes. Inconsistent results were observed between different protein concentrations in the range 7.5–150 mg/ml for particles <10 μm studied by optical techniques (light obscuration and flow microscopy). However, the Coulter counter measurements were consistent across the same studied concentration range but required sufficient solution conductivity from the formulation buffer or excipients. Our results show that currently available technologies, while allowing comparisons between samples of a given protein at a fixed concentration, may be unable to measure particle numbers accurately in a variety of protein formulations, e.g., at high concentration in sugar-based formulations.
引用
收藏
页码:708 / 715
页数:7
相关论文
共 50 条
  • [21] Advanced Technologies for Protein Complex Production and Characterization Preface
    Cristina Vega, M.
    Fernandez, Francisco J.
    Berger, Imre
    ADVANCED TECHNOLOGIES FOR PROTEIN COMPLEX PRODUCTION AND CHARACTERIZATION, 2016, 896 : V - VII
  • [22] Rapid monitoring of recombinant protein products: a comparison of current technologies
    Baker, KN
    Rendall, MH
    Patel, A
    Boyd, P
    Hoare, M
    Freedman, RB
    James, DC
    TRENDS IN BIOTECHNOLOGY, 2002, 20 (04) : 149 - 156
  • [23] CHARACTERIZATION OF MAGNETIC FORCES BY MEANS OF SUSPENDED PARTICLES IN PARAMAGNETIC SOLUTIONS
    ZIMMELS, Y
    YANIV, I
    IEEE TRANSACTIONS ON MAGNETICS, 1976, 12 (04) : 359 - 368
  • [24] Morphology of protein particles produced by spray freezing of concentrated solutions
    Engstrom, Josh D.
    Simpson, Dale T.
    Lai, Edwina S.
    Williams, Robert O., III
    Johnston, Keith P.
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2007, 65 (02) : 149 - 162
  • [25] Chromatographic removal of endotoxin from protein solutions by polymer particles
    Hirayama, C
    Sakata, M
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 781 (1-2): : 419 - 432
  • [26] Are we reaching the limits or our ability to detect skin effects with our current testing and measuring methods for consumer products?
    Farage, MA
    CONTACT DERMATITIS, 2005, 52 (06) : 297 - 303
  • [27] Characterization of supersaturated protein solutions in microgravity.
    Wilson, LJ
    Orr, P
    Brown, A
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 223 : U653 - U653
  • [28] A Microliter Capillary Rheometer for Characterization of Protein Solutions
    Hudson, Steven D.
    Sarangapani, Prasad
    Pathak, Jai A.
    Migler, Kalman B.
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2015, 104 (02) : 678 - 685
  • [29] Multiple views deliver complete characterization of protein particles
    Challener, Cynthia A.
    Pharmaceutical Technology, 2018, 42 (04): : 56 - 58